Utilization of a two-material decomposition from a single-source, dual-energy CT in acute traumatic vertebral fractures

被引:0
|
作者
Tivnan, Patrick [1 ]
Kaliaev, Artem [1 ]
Anderson, Stephan W. [1 ]
LeBedis, Christina A. [1 ]
Li, Baojun [1 ]
Andreu-Arasa, V. Carlota [1 ]
机构
[1] Boston Univ, Sch Med, Dept Radiol, Boston, MA 02215 USA
来源
FRONTIERS IN RADIOLOGY | 2023年 / 3卷
关键词
fracture; bone marrow edema; dual-energy computed tomography; magnetic resonance imaging; calcium; fat density; water density; BONE-MARROW EDEMA; MULTIDETECTOR CT; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; INJURIES; DISPLAY;
D O I
10.3389/fradi.2023.1187449
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study is to utilize a two-material decomposition to quantify bone marrow edema on a dual-energy computed tomography (DECT) scanner at the cervical, thoracic, and lumbar spine acute fractures in correlation with short tau inversion recovery (STIR) hyperintensity on magnetic resonance imaging (MRI) in comparison with the normal bone marrow. Materials and methods: This retrospective institutional review board-approved study gathered patients over 18 years old who had acute cervical, thoracic, or lumbar spinal fractures scanned on a DECT scanner. Those who had a spinal MRI done with bone marrow STIR hyperintensity within 3 weeks of the DECT were included. The water (calcium) and fat (calcium) density (mg/cm(3)) measurements of the region of interest of the bone marrow were obtained at a normal anatomic equivalent site and at the fracture site where STIR hyperintensity was noted on MRI. A statistical analysis was performed using the paired t-test and Wilcoxon signed rank test (p > 0.05). Results: A total of 20 patients met the inclusion criteria (males n = 17 males, females n = 3). A total of 32 fractures were analyzed: 19 cervical and 13 thoracolumbar. There were statistically significant differences in the water (43 +/- 24 mg/cm(3)) and fat (36 +/- 31 mg/cm(3)) density (mg/cm(3)) at the acute thoracic and lumbar spine fractures in correlation with edema on STIR images (both paired t-test <0.001, both Wilcoxon signed ranked test p < 0.01). There were no significant differences in the water (-10 +/- 46 mg/cm(3)) or fat (+7 +/- 50 mg/cm(3)) density (mg/cm(3)) at the cervical spine fractures. Conclusion: The DECT two-material decomposition using water (calcium) and fat (calcium) analyses has the ability to quantify a bone marrow edema at the acute fracture site in the thoracic and lumbar spine.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Calibration-Free Material Decomposition for Dual-Energy CT
    Zhao, W.
    Xing, L.
    Zhang, Q.
    Xiong, G.
    Min, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3396 - 3396
  • [32] Coronary Artery Imaging with Single-Source Rapid Kilovolt Peak-Switching Dual-Energy CT
    Scheske, Jonathan A.
    O'Brien, Julie M.
    Earls, James P.
    Min, James K.
    LaBounty, Troy M.
    Cury, Ricardo C.
    Lee, Ting-Yim
    So, Aaron
    Hague, Cameron J.
    Al-Hassan, Donya
    Kuriyabashi, Sachio
    Dowe, David A.
    Leipsic, Jonathon A.
    RADIOLOGY, 2013, 268 (03) : 702 - 709
  • [33] Motion artifacts in kidney stone imaging using single-source and dual-source dual-energy CT scanners: a phantom study
    El-Sayed H. Ibrahim
    Joseph G. Cernigliaro
    Robert A. Pooley
    James C. Williams
    William E. Haley
    Abdominal Imaging, 2015, 40 : 3161 - 3167
  • [34] Management of vertebral compression fractures: the role of dual-energy CT in clinical practice
    Giovanni Foti
    Fabio Lombardo
    Massimo Guerriero
    Tommaso Rodella
    Carmelo Cicciò
    Niccolò Faccioli
    Gerardo Serra
    Guglielmo Manenti
    La radiologia medica, 2022, 127 : 627 - 636
  • [35] Motion artifacts in kidney stone imaging using single-source and dual-source dual-energy CT scanners: a phantom study
    Ibrahim, El-Sayed H.
    Cernigliaro, Joseph G.
    Pooley, Robert A.
    Williams, James C.
    Haley, William E.
    ABDOMINAL IMAGING, 2015, 40 (08): : 3161 - 3167
  • [36] Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT
    Wang, Chien-Kuo
    Tsai, Jen-Ming
    Chuang, Ming-Tsung
    Wang, Min-Tsung
    Huang, Kuo-Yuan
    Lin, Ruey-Mo
    RADIOLOGY, 2013, 269 (02) : 524 - 532
  • [37] Dual-Energy CT: A Paradigm Shift in Acute Traumatic Abdomen
    Hamid, Saira
    Nicolaou, Savvas
    Khosa, Faisal
    Andrews, Gordon
    Murray, Nicolas
    Abdellatif, Waleed
    Qamar, Sadia Raheez
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2020, 71 (03): : 371 - 387
  • [38] Management of vertebral compression fractures: the role of dual-energy CT in clinical practice
    Foti, Giovanni
    Lombardo, Fabio
    Guerriero, Massimo
    Rodella, Tommaso
    Ciccio, Carmelo
    Faccioli, Niccolo
    Serra, Gerardo
    Manenti, Guglielmo
    RADIOLOGIA MEDICA, 2022, 127 (06): : 627 - 636
  • [39] Correction to: Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout
    Torsten Diekhoff
    Michael Scheel
    Sandra Hermann
    Jürgen Mews
    Bernd Hamm
    Kay Geert A. Hermann
    Skeletal Radiology, 2018, 47 : 1719 - 1719
  • [40] First experience with single-source, dual-energy CCTA for monochromatic stent imaging
    Stehli, Julia
    Fuchs, Tobias A.
    Singer, Adrian
    Bull, Sacha
    Clerc, Olivier F.
    Possner, Mathias
    Gaemperli, Oliver
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (05) : 507 - 512