Utilization of a two-material decomposition from a single-source, dual-energy CT in acute traumatic vertebral fractures

被引:0
|
作者
Tivnan, Patrick [1 ]
Kaliaev, Artem [1 ]
Anderson, Stephan W. [1 ]
LeBedis, Christina A. [1 ]
Li, Baojun [1 ]
Andreu-Arasa, V. Carlota [1 ]
机构
[1] Boston Univ, Sch Med, Dept Radiol, Boston, MA 02215 USA
来源
FRONTIERS IN RADIOLOGY | 2023年 / 3卷
关键词
fracture; bone marrow edema; dual-energy computed tomography; magnetic resonance imaging; calcium; fat density; water density; BONE-MARROW EDEMA; MULTIDETECTOR CT; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; INJURIES; DISPLAY;
D O I
10.3389/fradi.2023.1187449
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study is to utilize a two-material decomposition to quantify bone marrow edema on a dual-energy computed tomography (DECT) scanner at the cervical, thoracic, and lumbar spine acute fractures in correlation with short tau inversion recovery (STIR) hyperintensity on magnetic resonance imaging (MRI) in comparison with the normal bone marrow. Materials and methods: This retrospective institutional review board-approved study gathered patients over 18 years old who had acute cervical, thoracic, or lumbar spinal fractures scanned on a DECT scanner. Those who had a spinal MRI done with bone marrow STIR hyperintensity within 3 weeks of the DECT were included. The water (calcium) and fat (calcium) density (mg/cm(3)) measurements of the region of interest of the bone marrow were obtained at a normal anatomic equivalent site and at the fracture site where STIR hyperintensity was noted on MRI. A statistical analysis was performed using the paired t-test and Wilcoxon signed rank test (p > 0.05). Results: A total of 20 patients met the inclusion criteria (males n = 17 males, females n = 3). A total of 32 fractures were analyzed: 19 cervical and 13 thoracolumbar. There were statistically significant differences in the water (43 +/- 24 mg/cm(3)) and fat (36 +/- 31 mg/cm(3)) density (mg/cm(3)) at the acute thoracic and lumbar spine fractures in correlation with edema on STIR images (both paired t-test <0.001, both Wilcoxon signed ranked test p < 0.01). There were no significant differences in the water (-10 +/- 46 mg/cm(3)) or fat (+7 +/- 50 mg/cm(3)) density (mg/cm(3)) at the cervical spine fractures. Conclusion: The DECT two-material decomposition using water (calcium) and fat (calcium) analyses has the ability to quantify a bone marrow edema at the acute fracture site in the thoracic and lumbar spine.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Targeted dual-energy single-source CT for characterisation of urinary calculi: experimental and clinical experience
    Matthias Eiber
    Konstantin Holzapfel
    Markus Frimberger
    Michael Straub
    Heike Schneider
    Ernst J. Rummeny
    Martin Dobritz
    Armin Huber
    European Radiology, 2012, 22 : 251 - 258
  • [22] Adrenal Incidentaloma Triage With Single-Source (Fast-Kilovoltage Switch) Dual-Energy CT
    Glazer, Daniel I.
    Maturen, Katherine E.
    Kaza, Ravi K.
    Francis, Isaac R.
    Keshavarzi, Nahid R.
    Parker, Robert A.
    Platt, Joel F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) : 329 - 335
  • [23] Estimating dual-energy CT imaging from single-energy CT data with material decomposition convolutional neural network ?
    Lyu, Tianling
    Zhao, Wei
    Zhu, Yinsu
    Wu, Zhan
    Zhang, Yikun
    Chen, Yang
    Luo, Limin
    Li, Shuo
    Xing, Lei
    MEDICAL IMAGE ANALYSIS, 2021, 70
  • [24] Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout
    Diekhoff, Torsten
    Scheel, Michael
    Hermann, Sandra
    Mews, Jurgen
    Hamm, Bernd
    Hermann, Kay-Geert A.
    SKELETAL RADIOLOGY, 2017, 46 (02) : 185 - 190
  • [25] Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout
    Torsten Diekhoff
    Michael Scheel
    Sandra Hermann
    Jürgen Mews
    Bernd Hamm
    Kay-Geert A. Hermann
    Skeletal Radiology, 2017, 46 : 185 - 190
  • [26] Material decomposition using dual-energy CT with unsupervised learning
    Chang, Hui-Yu
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (04) : 1607 - 1617
  • [27] Impact of monochromatic coronary computed tomography angiography from single-source dual-energy CT on coronary stenosis quantification
    Stehli, Julia
    Clerc, Olivier F.
    Fuchs, Tobias A.
    Possner, Mathias
    Graeni, Christoph
    Benz, Dominik C.
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (02) : 135 - 140
  • [28] A comparison of material decomposition techniques for dual-energy CT colonography
    Nasirudin, Radin A.
    Tachibana, Rie
    Naeppi, Janne J.
    Mei, Kai
    Kopp, Felix K.
    Rummeny, Ernst J.
    Yoshida, Hiroyuki
    Noel, Peter B.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [29] Material decomposition using dual-energy CT with unsupervised learning
    Hui-Yu Chang
    Chi-Kuang Liu
    Hsuan-Ming Huang
    Physical and Engineering Sciences in Medicine, 2023, 46 : 1607 - 1617
  • [30] Dual-Energy CT Material Decomposition in Pediatric Thoracic Oncology
    Siegel, Marilyn J.
    Bhalla, Sanjeev
    Cullinane, Mike
    RADIOLOGY-IMAGING CANCER, 2021, 3 (01):