Development of a High-Frequency Mini-Convex Array Probe for Intraluminal Ultrasonic Imaging Applications

被引:0
|
作者
Chen, Weicen [1 ]
Wang, Boquan [1 ]
Chen, Jianzhong [1 ]
You, Chenzhi [1 ]
Yao, Jing [2 ,3 ]
Wu, Dawei [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Aerosp Engn, State Key Lab Mech & Control Aerosp Struct, Nanjing 210016, Peoples R China
[2] Nanjing Univ, Dept Ultrasound Med, Nanjing 210008, Peoples R China
[3] Nanjing Univ, Nanjing Drum Tower Hosp, Affiliated Hosp, Med Imaging Ctr,Med Sch, Nanjing 210008, Peoples R China
基金
美国国家科学基金会;
关键词
Probes; Imaging; Transducers; Ultrasonic imaging; Catheters; Fabrication; Visualization; Field of view; forward or side-looking (SL); high frequency; intraluminal ultrasonic (ILUS); mini-convex array; INTRAVASCULAR ULTRASOUND; INTRACARDIAC ECHOCARDIOGRAPHY; MATCHING LAYERS; 2-D ARRAY; REAL-TIME; CATHETER; TRANSDUCER;
D O I
10.1109/JSEN.2024.3392915
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Intraluminal ultrasonic (ILUS) technology, an advanced interventional imaging technique, employs a miniaturized high-frequency ultrasound transducer mounted at the tip of a thin catheter to visualize anatomical structures within the human body. This allows for the acquisition of high-quality images of lesions in close proximity. However, existing ILUS probes predominantly offer specialized visualization in a single direction of the ultrasound catheter due to space constraints within the catheter, posing challenges to the fabrication process. In this study, an ILUS high-frequency mini-convex array probe was developed which featured 64 array elements arranged in a curvilinear configuration, providing a 90 degrees imaging field of view. The mini-convex array was housed within a stainless-steel tube with an outer diameter of 4 mm, positioned such that its central imaging axis was oriented at a 45 degrees angle relative to the axial direction of the tube. This configuration enabled observation of objects ahead of the catheter, even though not entirely covered, and offered detailed features of the interior configuration on its side. This probe exhibited an average center frequency, -6 dB bandwidth, and sensitivity of approximately 17.85 MHz, 61.95%, and 32.64 mV, respectively. Imaging of a wire phantom yielded axial and lateral resolutions at 5 mm depth of approximately 0.11 and 0.25 mm, respectively. Subsequently, the actual imaging capability was assessed through ex vivo imaging of the artery and esophagus of a swine, demonstrating the suitability of the high-frequency mini-convex array probe for ILUS imaging applications.
引用
收藏
页码:17560 / 17569
页数:10
相关论文
共 50 条
  • [41] High-frequency ultrasonic imaging:: A spatio-temporal approach of rheology
    Manneville, S
    Bécu, L
    Grondin, P
    Colin, A
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2005, 270 : 195 - 204
  • [42] Sidelobe reduction for synthetic aperture focusing in high-frequency ultrasonic imaging
    Li, ML
    Guan, WJ
    Li, PC
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 1557 - 1560
  • [43] FIELD-EMITTER-ARRAY DEVELOPMENT FOR HIGH-FREQUENCY OPERATION
    SPINDT, CA
    HOLLAND, CE
    ROSENGREEN, A
    BRODIE, I
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1993, 11 (02): : 468 - 473
  • [44] Frequency-domain photoacoustic phased array probe for biomedical imaging applications
    Telenkov, Sergey
    Alwi, Rudolf
    Mandelis, Andreas
    Worthington, Arthur
    OPTICS LETTERS, 2011, 36 (23) : 4560 - 4562
  • [45] Development of a real-time, high-frequency ultrasound digital beamformer for high-frequency linear array transducers
    Hu, CH
    Xu, XC
    Cannata, JM
    Yen, JT
    Shung, KK
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (02) : 317 - 323
  • [46] High-frequency ultrasonographic imaging of avian cardiovascular development
    McQuinn, Tim C.
    Bratoeva, Momka
    deAlmeida, Angela
    Remond, Mathieu
    Thompson, Robert P.
    Sedmera, David
    DEVELOPMENTAL DYNAMICS, 2007, 236 (12) : 3503 - 3513
  • [47] HIGH-FREQUENCY PULSE-COMPRESSION ULTRASOUND IMAGING WITH AN ANNULAR ARRAY
    Mamou, J.
    Ketterling, J. A.
    Silverman, R. H.
    ACOUSTICAL IMAGING, VOL 29, 2008, 29 : 81 - 86
  • [48] High frequency piezoelectric micromachined ultrasonic transducers for imaging applications
    Zhou, Q. F.
    Shung, K. K.
    Zhang, Q.
    Djuth, F. T.
    MICRO (MEMS) AND NANOTECHNOLOGIES FOR SPACE APPLICATIONS, 2006, 6223
  • [49] Sparse Orthogonal Diverging Wave Imaging on a High-Frequency Phased Array
    Samson, Christopher
    Simpson, Eric
    Adamson, Robert
    Brown, Jeremy A.
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [50] Field emitter array development for high frequency applications
    Jensen, KL
    Abrams, RH
    Parker, RK
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1998, 16 (02): : 749 - 753