Development of a High-Frequency Mini-Convex Array Probe for Intraluminal Ultrasonic Imaging Applications

被引:0
|
作者
Chen, Weicen [1 ]
Wang, Boquan [1 ]
Chen, Jianzhong [1 ]
You, Chenzhi [1 ]
Yao, Jing [2 ,3 ]
Wu, Dawei [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Aerosp Engn, State Key Lab Mech & Control Aerosp Struct, Nanjing 210016, Peoples R China
[2] Nanjing Univ, Dept Ultrasound Med, Nanjing 210008, Peoples R China
[3] Nanjing Univ, Nanjing Drum Tower Hosp, Affiliated Hosp, Med Imaging Ctr,Med Sch, Nanjing 210008, Peoples R China
基金
美国国家科学基金会;
关键词
Probes; Imaging; Transducers; Ultrasonic imaging; Catheters; Fabrication; Visualization; Field of view; forward or side-looking (SL); high frequency; intraluminal ultrasonic (ILUS); mini-convex array; INTRAVASCULAR ULTRASOUND; INTRACARDIAC ECHOCARDIOGRAPHY; MATCHING LAYERS; 2-D ARRAY; REAL-TIME; CATHETER; TRANSDUCER;
D O I
10.1109/JSEN.2024.3392915
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Intraluminal ultrasonic (ILUS) technology, an advanced interventional imaging technique, employs a miniaturized high-frequency ultrasound transducer mounted at the tip of a thin catheter to visualize anatomical structures within the human body. This allows for the acquisition of high-quality images of lesions in close proximity. However, existing ILUS probes predominantly offer specialized visualization in a single direction of the ultrasound catheter due to space constraints within the catheter, posing challenges to the fabrication process. In this study, an ILUS high-frequency mini-convex array probe was developed which featured 64 array elements arranged in a curvilinear configuration, providing a 90 degrees imaging field of view. The mini-convex array was housed within a stainless-steel tube with an outer diameter of 4 mm, positioned such that its central imaging axis was oriented at a 45 degrees angle relative to the axial direction of the tube. This configuration enabled observation of objects ahead of the catheter, even though not entirely covered, and offered detailed features of the interior configuration on its side. This probe exhibited an average center frequency, -6 dB bandwidth, and sensitivity of approximately 17.85 MHz, 61.95%, and 32.64 mV, respectively. Imaging of a wire phantom yielded axial and lateral resolutions at 5 mm depth of approximately 0.11 and 0.25 mm, respectively. Subsequently, the actual imaging capability was assessed through ex vivo imaging of the artery and esophagus of a swine, demonstrating the suitability of the high-frequency mini-convex array probe for ILUS imaging applications.
引用
收藏
页码:17560 / 17569
页数:10
相关论文
共 50 条
  • [21] High-frequency mini-probe ultrasound: The rodney dangerfield of endoscopy?
    Schembre, D
    Ayub, K
    Jiranek, G
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2005, 39 (07) : 555 - 556
  • [22] FABRICATION OF SYSTEM WITH PROBE FOR HIGH-FREQUENCY MEASUREMENT APPLICATIONS
    Matsumoto, Keiji
    Choi, Woon
    Tomokage, Hajime
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2010, 52 (09) : 2083 - 2087
  • [23] Development of negative-group-delay circuit for high-frequency ultrasonic transducer applications
    Choi, Hojong
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 299
  • [24] High-frequency PIN-PMN-PT single crystal ultrasonic transducer for imaging applications
    Chen, Y.
    Lam, K. H.
    Zhou, D.
    Cheng, W. F.
    Dai, J. Y.
    Luo, H. S.
    Chan, H. L. W.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2012, 108 (04): : 987 - 991
  • [25] High frequency focused imaging for ultrasonic probe integrity inspection
    Svilainis, Linas
    Kybartas, Darius
    Aleksandrovas, Arturas
    Gomez Alvarez-Arenas, Tomas E.
    NDT & E INTERNATIONAL, 2020, 116
  • [26] HIGH-FREQUENCY ULTRASONIC-IMAGING OF SKIN - EXPERIMENTAL RESULTS
    DINES, KA
    SHEETS, PW
    BRINK, JA
    HANKE, CW
    CONDRA, KA
    CLENDENON, JL
    GOSS, SA
    SMITH, DJ
    FRANKLIN, TD
    ULTRASONIC IMAGING, 1984, 6 (04) : 408 - 434
  • [27] HIGH-FREQUENCY ULTRASONIC-IMAGING AND CHARACTERIZATION OF INTRAOCULAR TUMORS
    SILVERMAN, RH
    COLEMAN, DJ
    LIZZI, FL
    WOODS, SM
    RONDEAU, MJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1253 - 1253
  • [28] High frequency ultrasonic imaging and its applications in skin
    Ermert, H
    Vogt, M
    MEDICAL IMAGING 1999: ULTRASONIC TRANSDUCER ENGINEERING, 1999, 3664 : 44 - 55
  • [29] Identification of different patterns of pressure waves in achalasia of the esophagus by high-frequency intraluminal probe sonography
    Pehlivanov, N
    Liu, JM
    Mittal, R
    GASTROENTEROLOGY, 2002, 122 (04) : A341 - A341
  • [30] HIGH-FREQUENCY ULTRASONIC IMAGING OF GROWTH AND DEVELOPMENT IN MANUFACTURED ENGINEERED ORAL MUCOSAL TISSUE SURFACES
    Winterroth, Frank
    Kato, Hiroko
    Kuo, Shiuhyang
    Feinberg, Stephen E.
    Hollister, Scott J.
    Fowlkes, J. Brian
    Hollman, Kyle W.