Development of a High-Frequency Mini-Convex Array Probe for Intraluminal Ultrasonic Imaging Applications

被引:0
|
作者
Chen, Weicen [1 ]
Wang, Boquan [1 ]
Chen, Jianzhong [1 ]
You, Chenzhi [1 ]
Yao, Jing [2 ,3 ]
Wu, Dawei [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Aerosp Engn, State Key Lab Mech & Control Aerosp Struct, Nanjing 210016, Peoples R China
[2] Nanjing Univ, Dept Ultrasound Med, Nanjing 210008, Peoples R China
[3] Nanjing Univ, Nanjing Drum Tower Hosp, Affiliated Hosp, Med Imaging Ctr,Med Sch, Nanjing 210008, Peoples R China
基金
美国国家科学基金会;
关键词
Probes; Imaging; Transducers; Ultrasonic imaging; Catheters; Fabrication; Visualization; Field of view; forward or side-looking (SL); high frequency; intraluminal ultrasonic (ILUS); mini-convex array; INTRAVASCULAR ULTRASOUND; INTRACARDIAC ECHOCARDIOGRAPHY; MATCHING LAYERS; 2-D ARRAY; REAL-TIME; CATHETER; TRANSDUCER;
D O I
10.1109/JSEN.2024.3392915
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Intraluminal ultrasonic (ILUS) technology, an advanced interventional imaging technique, employs a miniaturized high-frequency ultrasound transducer mounted at the tip of a thin catheter to visualize anatomical structures within the human body. This allows for the acquisition of high-quality images of lesions in close proximity. However, existing ILUS probes predominantly offer specialized visualization in a single direction of the ultrasound catheter due to space constraints within the catheter, posing challenges to the fabrication process. In this study, an ILUS high-frequency mini-convex array probe was developed which featured 64 array elements arranged in a curvilinear configuration, providing a 90 degrees imaging field of view. The mini-convex array was housed within a stainless-steel tube with an outer diameter of 4 mm, positioned such that its central imaging axis was oriented at a 45 degrees angle relative to the axial direction of the tube. This configuration enabled observation of objects ahead of the catheter, even though not entirely covered, and offered detailed features of the interior configuration on its side. This probe exhibited an average center frequency, -6 dB bandwidth, and sensitivity of approximately 17.85 MHz, 61.95%, and 32.64 mV, respectively. Imaging of a wire phantom yielded axial and lateral resolutions at 5 mm depth of approximately 0.11 and 0.25 mm, respectively. Subsequently, the actual imaging capability was assessed through ex vivo imaging of the artery and esophagus of a swine, demonstrating the suitability of the high-frequency mini-convex array probe for ILUS imaging applications.
引用
收藏
页码:17560 / 17569
页数:10
相关论文
共 50 条
  • [1] Synthetic Aperture Imaging Using High-Frequency Convex Array for Ophthalmic Ultrasound Applications
    Lim, Hae Gyun
    Kim, Hyung Ham
    Yoon, Changhan
    SENSORS, 2021, 21 (07)
  • [2] A Review of High-Frequency Ultrasonic Transducers for Photoacoustic Imaging Applications
    Ren, Danyang
    Li, Chiye
    Shi, Junhui
    Chen, Ruimin
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (06) : 1848 - 1858
  • [3] Measuring esophageal distention by high-frequency intraluminal ultrasound probe
    Mittal, RK
    AMERICAN JOURNAL OF MEDICINE, 2003, 115 : 130S - 136S
  • [4] Development of Broadband High-Frequency Piezoelectric Micromachined Ultrasonic Transducer Array
    Wang, Xu-Bo
    He, Le-Ming
    Ma, You-Cao
    Liu, Wen-Juan
    Xu, Wei-Jiang
    Ren, Jun-Yan
    Riaud, Antoine
    Zhou, Jia
    SENSORS, 2021, 21 (05) : 1 - 10
  • [5] Measuring esophageal distension by high-frequency intraluminal ultrasound probe
    Rhee, PL
    Liu, JM
    Puckett, JL
    Mittal, RK
    AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2002, 283 (04): : G886 - G892
  • [6] HIGH-FREQUENCY ULTRASONIC PROBE WITH ACTIVE DAMPING
    OURAK, M
    RAVEZ, M
    NONGAILLARD, B
    OUAFTOUH, M
    JOURNAL DE PHYSIQUE IV, 1992, 2 (C1): : 665 - 668
  • [7] High-Frequency Endoscopic Linear Arrays for Intraluminal Imaging
    Roa, Carlos-Felipe
    Yin, Jianhua
    Boyes, Aaron
    Cherin, Emmanuel
    Singh, Nidhi
    Motlagh, Bahar
    Foster, F. Stuart
    Demore, Christine E. M.
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [8] High-frequency ultrasonic imaging of the anterior segment using an annular array transducer
    Silverman, Ronald H.
    Ketterling, Jeffrey A.
    Coleman, D. Jackson
    OPHTHALMOLOGY, 2007, 114 (04) : 816 - 822
  • [9] Design and Experiment of Capacitive Micromachined Ultrasonic Transducer Array for High-frequency Underwater Imaging
    Yu, Yuanyu
    Wang, Jiujiang
    Liu, Xin
    Pun, Sio H.
    Qiu, Weibao
    Zhang, Shuang
    Cheng, Ching H.
    Lei, Kin F.
    Vai, Mang, I
    Mak, Peng U.
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2021, 14 (02) : 233 - 240
  • [10] Design and experiment of capacitive micromachined ultrasonic transducer array for high-frequency underwater imaging
    Yu, Yuanyu
    Wang, Jiujiang
    Liu, Xin
    Pun, Sio H.
    Qiu, Weibao
    Zhang, Shuang
    Cheng, Ching H.
    Lei, Kin F.
    Vai, Mang I.
    Mak, Peng U.
    Recent Advances in Electrical and Electronic Engineering, 2021, 14 (02): : 233 - 240