A microfluidic ratiometric electrochemical aptasensor for highly sensitive and selective detection of 3,3′,4,4′-tetrachlorobiphenyl

被引:0
|
作者
Ji, Zhiheng [1 ]
Wang, Dou [1 ]
Wang, Juan [1 ]
机构
[1] Shanghai Univ Elect Power, Shanghai Key Lab Mat Protect & Adv Mat Elect Power, Shanghai 200090, Peoples R China
关键词
POLYCHLORINATED-BIPHENYLS; PCBS;
D O I
10.1039/d4ay00830h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study proposes a strategy using a microfluidic ratiometric electrochemical aptasensor to detect PCB77 with excellent sensitivity and specificity. This sensing platform combines a microfluidic chip, a wireless integrated circuit system for aptamer-based electrochemical detection, and a mobile phone control terminal for parameter configuration, identification, observation, and wireless data transfer. The sensing method utilizes a cDNA (MB-COOH-cDNA-SH) that is labelled with the redox probe Methylene Blue (MB) at the 5 ' end and has a thiol group at the 3 ' end. Additionally, it utilizes a single strand PCB aptamer that has been modified with ferrocenes at the 3 ' end (aptamer-Fc). Through gold-thiol binding, the labelled probe of MB-COOH-cDNA-SH was self-assembled onto the surface of an Au/Nb2CTx/GO modified electrode. On exposure to aptamer-Fc, it will hybridize with MB-COOH-cDNA-SH to form a stable double-stranded structure on the electrode surface. When PCB77 is present, aptamer-Fc binds specifically to the target, enabling the double-stranded DNA to unwind. Such variation caused changes in the differential pulse voltammetry (DPV) peak currents of both MB and Fc. A substantial improvement is observed in the ratio between the two DPV peaks. Under the optimum experimental conditions, this assay has a response that covers the 0.0001 to 1000 ng mL-1 PCB77 concentration range, and the detection limit is 1.56 x 10-5 ng mL-1. The integration of a ratiometric electrochemical aptasensor with designed microfluidic and integrated devices in this work is an innovative and promising approach that offers an efficient platform for on-site applications. The portable ratiometric electrochemical sensing platform combines a microfluidic chip, a wireless integrated circuit system and a mobile phone control terminal for highly sensitive and selective detection of 3,3 ',4,4 '-tetrachlorobiphenyl.
引用
收藏
页码:4160 / 4167
页数:8
相关论文
共 50 条
  • [31] Highly Sensitive and Selective Surface-Enhanced Raman Spectroscopy Label-free Detection of 3,3′,4,4′-Tetrachlorobiphenyl Using DNA Aptamer-Modified Ag-Nanorod Arrays
    Sun, Kexi
    Huang, Qing
    Meng, Guowen
    Lu, Yilin
    ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (08) : 5723 - 5728
  • [32] THE DISPOSITION AND THE LIVER AND THYMUS GLAND TOXICITY OF 3,3',4,4'-TETRACHLOROBIPHENYL IN THE FEMALE RAT
    CLARKE, DW
    BRIEN, JF
    RACZ, WJ
    NAKATSU, K
    MARKS, GS
    CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1984, 62 (10) : 1253 - 1260
  • [33] RETINYL ESTER HYDROLASE AND VITAMIN A STATUS IN RATS TREATED WITH 3,3',4,4'-TETRACHLOROBIPHENYL
    MERCIER, M
    PASCAL, G
    AZAISBRAESCO, V
    BIOCHIMICA ET BIOPHYSICA ACTA, 1990, 1047 (01) : 70 - 76
  • [34] TOXICITY AND DISTRIBUTION IN CHICK-EMBRYOS OF 3,3',4,4'-TETRACHLOROBIPHENYL INJECTED INTO THE EGGS
    BRUNSTROM, B
    DARNERUD, PO
    TOXICOLOGY, 1983, 27 (02) : 103 - 110
  • [35] In Vivo Biotransformation of 3,3′,4,4′-Tetrachlorobiphenyl by Whole Plants-Poplars and Switchgrass
    Liu, Jiyan
    Hu, Dingfei
    Jiang, Guibin
    Schnoor, Jerald L.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (19) : 7503 - 7509
  • [36] MODULATION OF HEPATOCYTE GROWTH BY 3,3',4,4'-TETRACHLOROBIPHENYL (TCB) IN NORMAL AND INITIATED HEPATOCYTES
    WOLFLE, D
    LILIENBLUM, W
    FISCHER, G
    BOCK, KW
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 1985, 109 (02) : A20 - A20
  • [37] Effects on developmental landmarks and reproductive capability of 3,3′,4,4′-tetrachlorobiphenyl and 3,3′,4,4′,5-pentacholorobiphenyl in offspring of rats exposed during pregnancy
    Faqi, AS
    Dalsenter, PR
    Merker, HJ
    Chahoud, I
    HUMAN & EXPERIMENTAL TOXICOLOGY, 1998, 17 (07): : 365 - 372
  • [38] 3,3',4,4'-Tetrachlorobiphenyl affects cortisol dynamics and hepatic function in rainbow trout
    Vijayan, MM
    Feist, G
    Otto, DME
    Schreck, CB
    Moon, TW
    AQUATIC TOXICOLOGY, 1997, 37 (2-3) : 87 - 98
  • [39] 3,3′,4,4′-tetrachlorobiphenyl ′,4,4 ′-tetrachlorobiphenyl (PCB77) enhances human Kv1.3 channel currents and alters cytokine production
    Kim, Jong-Hui
    Hwang, Soobeen
    Park, Seo-In
    Lee, Hyo-Ji
    Jung, Yu-Jin
    Jo, Su-Hyun
    KOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY, 2024, 28 (04): : 323 - 333
  • [40] THE PHARMACOKINETICS OF 2,2',5,5'-TETRACHLOROBIPHENYL AND 3,3',4,4'-TETRACHLOROBIPHENYL AND ITS RELATIONSHIP TO TOXICITY
    CLEVENGER, MA
    ROBERTS, SM
    LATTIN, DL
    HARBISON, RD
    JAMES, RC
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 1989, 100 (02) : 315 - 327