A microfluidic ratiometric electrochemical aptasensor for highly sensitive and selective detection of 3,3′,4,4′-tetrachlorobiphenyl

被引:0
|
作者
Ji, Zhiheng [1 ]
Wang, Dou [1 ]
Wang, Juan [1 ]
机构
[1] Shanghai Univ Elect Power, Shanghai Key Lab Mat Protect & Adv Mat Elect Power, Shanghai 200090, Peoples R China
关键词
POLYCHLORINATED-BIPHENYLS; PCBS;
D O I
10.1039/d4ay00830h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study proposes a strategy using a microfluidic ratiometric electrochemical aptasensor to detect PCB77 with excellent sensitivity and specificity. This sensing platform combines a microfluidic chip, a wireless integrated circuit system for aptamer-based electrochemical detection, and a mobile phone control terminal for parameter configuration, identification, observation, and wireless data transfer. The sensing method utilizes a cDNA (MB-COOH-cDNA-SH) that is labelled with the redox probe Methylene Blue (MB) at the 5 ' end and has a thiol group at the 3 ' end. Additionally, it utilizes a single strand PCB aptamer that has been modified with ferrocenes at the 3 ' end (aptamer-Fc). Through gold-thiol binding, the labelled probe of MB-COOH-cDNA-SH was self-assembled onto the surface of an Au/Nb2CTx/GO modified electrode. On exposure to aptamer-Fc, it will hybridize with MB-COOH-cDNA-SH to form a stable double-stranded structure on the electrode surface. When PCB77 is present, aptamer-Fc binds specifically to the target, enabling the double-stranded DNA to unwind. Such variation caused changes in the differential pulse voltammetry (DPV) peak currents of both MB and Fc. A substantial improvement is observed in the ratio between the two DPV peaks. Under the optimum experimental conditions, this assay has a response that covers the 0.0001 to 1000 ng mL-1 PCB77 concentration range, and the detection limit is 1.56 x 10-5 ng mL-1. The integration of a ratiometric electrochemical aptasensor with designed microfluidic and integrated devices in this work is an innovative and promising approach that offers an efficient platform for on-site applications. The portable ratiometric electrochemical sensing platform combines a microfluidic chip, a wireless integrated circuit system and a mobile phone control terminal for highly sensitive and selective detection of 3,3 ',4,4 '-tetrachlorobiphenyl.
引用
收藏
页码:4160 / 4167
页数:8
相关论文
共 50 条
  • [1] Portable electrochemical aptasensor for highly sensitive detection of 3,3′,4,4′-tetrachlorobiphenyl
    Chen, Beibei
    Wang, Dou
    Wei, Shusheng
    Wang, Juan
    BIOSENSORS & BIOELECTRONICS, 2024, 260
  • [2] Design of a simple and novel photoelectrochemical aptasensor for detection of 3,3′,4,4′-tetrachlorobiphenyl
    Fan, Lifang
    Zhang, Caiyun
    Shi, Huijie
    Zhao, Guohua
    BIOSENSORS & BIOELECTRONICS, 2019, 124 : 8 - 14
  • [3] Reproductive Toxicology of 3,3′,4,4′-Tetrachlorobiphenyl in Mice
    J. Rodriguez
    S. D. Kholkute
    W. R. Dukelow
    Bulletin of Environmental Contamination and Toxicology, 1997, 58 : 999 - 1005
  • [4] TOXICOKINETICS OF 2,2',4,4'-TETRACHLOROBIPHENYL AND 3,3',4,4'-TETRACHLOROBIPHENYL CONGENERS IN THE HOUSE CRICKET
    LI, MH
    MCKEE, MJ
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 1992, 24 (03) : 309 - 318
  • [5] SENSITIVE SPECTROFLUOROMETRIC DETERMINATION OF 3,3',4,4'-TETRACHLOROBIPHENYL USING A NEUTRAL MICELLAR MEDIUM
    GARCIA, JH
    RODRIGUEZ, JRB
    MARTINLAZARO, AJB
    RODRIGUEZ, JJS
    ANALYTICA CHIMICA ACTA, 1994, 290 (1-2) : 146 - 153
  • [6] Biodegradation of 3,3′,4,4′- tetrachlorobiphenyl by Sinorhizobium meliloti NM
    Wang, Xiaomi
    Teng, Ying
    Luo, Yongming
    Dick, Richard P.
    BIORESOURCE TECHNOLOGY, 2016, 201 : 261 - 268
  • [7] 3,3',4,4'-TETRACHLOROBIPHENYL IN HUMAN FAT AND MILK SAMPLES
    BECK, H
    DROSS, A
    MATHAR, W
    CHEMOSPHERE, 1989, 19 (12) : 1805 - 1810
  • [8] EFFECTS OF 3,3',4,4'-TETRACHLOROBIPHENYL IN THE BRAIN OF THE NEONATAL MOUSE
    ERIKSSON, P
    TOXICOLOGY, 1988, 49 (01) : 43 - 48
  • [9] INFLUENCE OF SYMMETRICAL POLYCHLORINATED BIPHENYL ISOMERS ON EMBRYO AND FETAL DEVELOPMENT IN MICE .2. COMPARISON OF 4,4'-DICHLOROBIPHENYL, 3,3',4,4'-TETRACHLOROBIPHENYL, 3,3',5,5'-TETRACHLOROBIPHENYL, AND 3,3',4,4'-TETRAMETHYLBIPHENYL
    MARKS, TA
    KIMMEL, GL
    STAPLES, RE
    FUNDAMENTAL AND APPLIED TOXICOLOGY, 1989, 13 (04): : 681 - 693
  • [10] 3,3',4,4'-TETRACHLOROBIPHENYL AND 3,3',4,4',5-PENTACHLOROBIPHENYL-TISSUE-LOCALIZATION AND METABOLIC-FATE IN THE MOUSE
    WEHLER, EK
    JONSSON, J
    BERGMAN, A
    BRANDT, I
    DARNERUD, PO
    CHEMOSPHERE, 1989, 19 (1-6) : 809 - 812