Simultaneous multiple target detection platform based on vertical flow immunoassay

被引:0
|
作者
Yong, Taek [1 ]
Kim, Dami [2 ]
Kim, Sanghyo [1 ,2 ]
机构
[1] Gachon Univ, Dept Bionanotechnol, Seongnam 13120, South Korea
[2] Philmedi Inc, Philmedi R&D Ctr, 33 Sagimakgol Ro 62 Beon Gil, Seongnam 13211, South Korea
关键词
Vertical flow assay; Antigen -antibody binding; One-step detection; Gold nanoparticles; Multiple detection; POINT;
D O I
10.1016/j.jim.2024.113690
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In general, vertical flow assay (VFA) has a disadvantage of requiring a complex analysis process that involves manually injecting various reagents (target analyte, washing buffer, detection conjugate, etc.) sequentially. However, in this study, we have developed an innovative paper-based VFA device that replaces the complex analysis process with one-step and enables the detection of multiple targets. The fabrication process of the multitarget detection VFA device is as follows: preparation and pre-treatment of the strip materials, design of strip cartridge, design of the multiple detection VFA device, optimization experiments for strip sample flow rates, determination of device analysis time, determination of device limit of detection (LOD), multiple target signal uniformity experiment, immunoglobulin G (IgG) and C-reactive protein (CRP) antigen-antibody multiple detection experiment, and data extraction and analysis method. The use of paper-based materials enables the device to be produced at cost-effective, and cartridge production allowed for uniform array formation. IgG and CRP are used to evaluate the performance of the device as common biomarkers. The device proposed in this study is currently under research. To validate multiple target detection capability of the VFA device proposed in this study, two types of antigens-antibodies (Human IgG and Human CRP) were employed. The detection limit is 0.15 mu g/mL for IgG and 0.19 mu g/mL for CRP in naked eye. Furthermore, it was confirmed that there is no crossreactivity caused by the device structure through IgG and CRP antigens. In conclusion, the VFA device proposed in this study consists of a one-step analysis process, and it has been confirmed that it can detect multiple targets simultaneously.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Multiple vertical depression-based HMS active target detection using GSFM pulse
    Hong, Jungpyo
    Cho, Chomgun
    Kim, Geunhwan
    Lee, Kyunkyung
    Yoon, Kyungsik
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2020, 39 (04): : 237 - 245
  • [42] A multiple signal amplification based on PEI and rGO nanocomposite for simultaneous multiple electrochemical immunoassay
    Zhao, Xiaoqing
    Wang, Jing
    Chen, Hou
    Xu, Hui
    Bai, Liangjiu
    Wang, Wenxiang
    Yang, Huawei
    Wei, Donglei
    Yuan, Baiqing
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 301
  • [43] Development of a colloidal gold-based lateral-flow immunoassay for the rapid simultaneous detection of zearalenone and deoxynivalenol
    Kolosova, Anna Yu
    De Saeger, Sarah
    Sibanda, Liberty
    Verheijen, Ron
    Van Peteghem, Carlos
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (7-8) : 2103 - 2107
  • [44] An AgPd NP-based lateral flow immunoassay for simultaneous detection of glycocholic acid and alpha-fetoprotein
    Jiang, Shilin
    Chen, Yaqiong
    Liang, Jinhui
    Xiao, Huanxin
    Lin, Mingxia
    Cui, Xiping
    Zhao, Suqing
    ANALYTICAL METHODS, 2024, 16 (10) : 1508 - 1514
  • [45] Development of a colloidal gold-based lateral-flow immunoassay for the rapid simultaneous detection of zearalenone and deoxynivalenol
    Anna Yu Kolosova
    Sarah De Saeger
    Liberty Sibanda
    Ron Verheijen
    Carlos Van Peteghem
    Analytical and Bioanalytical Chemistry, 2007, 389 : 2103 - 2107
  • [46] Target Detection and Recognition System Based on PYNQ Platform
    Wang, Youzhong
    Zhu, Yanping
    Qi, Zhiyuan
    Chen, Jinli
    COMMUNICATIONS, SIGNAL PROCESSING, AND SYSTEMS, VOL. 1, 2022, 878 : 945 - 952
  • [47] Sensitive and simultaneous detection of multi-index lung cancer biomarkers by an NIR-II fluorescence lateral-flow immunoassay platform
    Ao, Lijiao
    Liao, Tao
    Huang, Liang
    Lin, Shan
    Xu, Kui
    Ma, Jiangtao
    Qiu, Shaorong
    Wang, Xiangyu
    Zhang, Qiqing
    CHEMICAL ENGINEERING JOURNAL, 2022, 436
  • [48] A latex bead-based flow cytometric immunoassay capable of simultaneous typing of multiple pneumococcal serotypes (multibead assay)
    Park, MK
    Briles, DE
    Nahm, MH
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2000, 7 (03) : 486 - 489
  • [49] Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform
    Shao, Guocheng
    Wang, Jun
    Li, Zhaohui
    Saraf, Laxmikant
    Wang, Wanjun
    Lin, Yuehe
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 159 (01): : 44 - 50
  • [50] Eu-Chelate Polystyrene Microsphere-Based Lateral Flow Immunoassay Platform for hs-CRP Detection
    Jin, Birui
    Du, Zhiguo
    Zhang, Chuyao
    Yu, Zhao
    Wang, Xuemin
    Hu, Jie
    Li, Zedong
    BIOSENSORS-BASEL, 2022, 12 (11):