Simultaneous multiple target detection platform based on vertical flow immunoassay

被引:0
|
作者
Yong, Taek [1 ]
Kim, Dami [2 ]
Kim, Sanghyo [1 ,2 ]
机构
[1] Gachon Univ, Dept Bionanotechnol, Seongnam 13120, South Korea
[2] Philmedi Inc, Philmedi R&D Ctr, 33 Sagimakgol Ro 62 Beon Gil, Seongnam 13211, South Korea
关键词
Vertical flow assay; Antigen -antibody binding; One-step detection; Gold nanoparticles; Multiple detection; POINT;
D O I
10.1016/j.jim.2024.113690
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In general, vertical flow assay (VFA) has a disadvantage of requiring a complex analysis process that involves manually injecting various reagents (target analyte, washing buffer, detection conjugate, etc.) sequentially. However, in this study, we have developed an innovative paper-based VFA device that replaces the complex analysis process with one-step and enables the detection of multiple targets. The fabrication process of the multitarget detection VFA device is as follows: preparation and pre-treatment of the strip materials, design of strip cartridge, design of the multiple detection VFA device, optimization experiments for strip sample flow rates, determination of device analysis time, determination of device limit of detection (LOD), multiple target signal uniformity experiment, immunoglobulin G (IgG) and C-reactive protein (CRP) antigen-antibody multiple detection experiment, and data extraction and analysis method. The use of paper-based materials enables the device to be produced at cost-effective, and cartridge production allowed for uniform array formation. IgG and CRP are used to evaluate the performance of the device as common biomarkers. The device proposed in this study is currently under research. To validate multiple target detection capability of the VFA device proposed in this study, two types of antigens-antibodies (Human IgG and Human CRP) were employed. The detection limit is 0.15 mu g/mL for IgG and 0.19 mu g/mL for CRP in naked eye. Furthermore, it was confirmed that there is no crossreactivity caused by the device structure through IgG and CRP antigens. In conclusion, the VFA device proposed in this study consists of a one-step analysis process, and it has been confirmed that it can detect multiple targets simultaneously.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A Portable Fluorescent Lateral Flow Immunoassay Platform for Rapid Detection of FluA
    Chen, Xu
    Huang, Xuhui
    Kanwal, Saima
    Wang, Jian
    Wen, Jing
    Zhang, Dawei
    BIOSENSORS-BASEL, 2024, 14 (06):
  • [22] A multiple lateral flow immunoassay based on AuNP for the detection of 5 chemical contaminants in milk
    Xue, Guangjian
    Wu, Mengyun
    Liu, Tingting
    Fang, Xuechen
    Yin, Jiaqi
    Lai, Weihua
    Peng, Juan
    JOURNAL OF DAIRY SCIENCE, 2023, 106 (06) : 3856 - 3867
  • [23] Multiplex enzyme immunoassay system for the simultaneous detection of multiple allergens in foods
    Blais, BW
    Gaudreault, M
    Phillippe, LM
    FOOD CONTROL, 2003, 14 (01) : 43 - 47
  • [24] An Electrokinetically-Controlled Immunoassay for Simultaneous Detection of Multiple Microbial Antigens
    Yali Gao
    Guoqing Hu
    Frank Y. H. Lin
    Philip M. Sherman
    Dongqing Li
    Biomedical Microdevices, 2005, 7 : 301 - 312
  • [25] An electrokinetically-controlled immunoassay for simultaneous detection of multiple microbial antigens
    Gao, YL
    Hu, GQ
    Lin, FYH
    Sherman, PM
    Li, DQ
    BIOMEDICAL MICRODEVICES, 2005, 7 (04) : 301 - 312
  • [26] Development of a Rainbow Lateral Flow Immunoassay for the Simultaneous Detection of Four Mycotoxins
    Foubert, Astrid
    Beloglazova, Natalia V.
    Gordienko, Anna
    Tessier, Mickael D.
    Drijvers, Emile
    Hens, Zeger
    De Saeger, Sarah
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (33) : 7121 - 7130
  • [27] Quick electrochemical immunoassay for hantavirus detection based on biochar platform
    Martins, Gustavo
    Gogola, Jeferson L.
    Gaetano, Fabio R.
    Kalinke, Cristiane
    Jorge, Taissa R.
    Santos, Claudia N. D.
    Bergamini, Marcio F.
    Marcolino-Junior, Luiz H.
    TALANTA, 2019, 204 : 163 - 171
  • [28] Multianalyte lateral flow immunoassay for simultaneous detection of protein-based inflammation biomarkers and pathogen DNA
    Klebes, Anna
    Kittel, Anna-Sophia
    Verboket, Rene D.
    von Stetten, Felix
    Fruh, Susanna M.
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 355
  • [29] Simultaneous detection of three nitrofuran antibiotics by the lateral flow immunoassay based on europium nanoparticles in aquatic products
    Mei, Qing
    Ma, Biao
    Li, Jiali
    Deng, Xin
    Shuai, Jiangbing
    Zhou, Yuxin
    Zhang, Mingzhou
    FOOD CHEMISTRY, 2024, 439
  • [30] A bare-eye-based lateral flow immunoassay based on the use of gold nanoparticles for simultaneous detection of three pesticides
    Wang, Limin
    Cai, Jia
    Wang, Yulong
    Fang, Qingkui
    Wang, Suyan
    Cheng, Qi
    Du, Dan
    Lin, Yuehe
    Liu, Fengquan
    MICROCHIMICA ACTA, 2014, 181 (13-14) : 1565 - 1572