Digital phantom versus patient-specific radiation dosimetry in adult routine thorax CT examinations

被引:2
|
作者
Papadakis, Antonios E. [1 ]
Giannakaki, Vassiliki [1 ]
Stratakis, John [1 ]
Myronakis, Marios [1 ]
Zaidi, Habib [2 ,3 ,4 ,5 ]
Damilakis, John [6 ]
机构
[1] Univ Hosp Heraklion, Med Phys Dept, Iraklion, Crete, Greece
[2] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[4] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[5] Obuda Univ, Univ Res & Innovat Ctr, Budapest, Hungary
[6] Univ Crete, Med Sch, Med Phys Dept, Iraklion, Crete, Greece
来源
关键词
CT; digital phantoms; dosimetry; experimental phantoms; Monte Carlo; HYBRID COMPUTATIONAL PHANTOMS; PEDIATRIC CHEST; VALIDATION; FAMILY; RISK;
D O I
10.1002/acm2.14389
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe aim of this study was to compare the organ doses assessed through a digital phantom-based and a patient specific-based dosimetric tool in adult routine thorax computed tomography (CT) examinations with reference to physical dose measurements performed in anthropomorphic phantoms.MethodsTwo Monte Carlo based dose calculation tools were used to assess organ doses in routine adult thorax CT examinations. These were a digital phantom-based dosimetry tool (NCICT, National Cancer Institute, USA) and a patient-specific individualized dosimetry tool (ImpactMC, CT Imaging GmbH, Germany). Digital phantoms and patients were classified in four groups according to their water equivalent diameter (Dw). Normalized to volume computed tomography dose index (CTDIvol), organ dose was assessed for lungs, esophagus, heart, breast, active bone marrow, and skin. Organ doses were compared to measurements performed using thermoluminescent detectors (TLDs) in two physical anthropomorphic phantoms that simulate the average adult individual as a male (Alderson Research Labs, USA) and as a female (ATOM Phantoms, USA).ResultsThe average percent difference of NCICT to TLD and ImpactMC to TLD dose measurements across all organs in both sexes was 13% and 6%, respectively. The average +/- 1 standard deviation in dose values across all organs with NCICT, ImpactMC, and TLDs was +/- 0.06 (mGy/mGy), +/- 0.19 (mGy/mGy), and +/- 0.13 (mGy/mGy), respectively. Organ doses decreased with increasing Dw in both NCICT and ImpactMC.ConclusionOrgan doses estimated with ImpactMC were in closer agreement to TLDs compared to NCICT. This may be attributed to the inherent property of ImpactMC methodology to generate phantoms that resemble the realistic anatomy of the examined patient as opposed to NCICT methodology that incorporates an anatomical discrepancy between phantoms and patients.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Patient-specific voxel phantom dosimetry during the prostate treatment with high-energy linac
    Najmeh Mohammadi
    Hashem Miri-Hakimabad
    Laleh Rafat-Motavalli
    Fatemeh Akbari
    Sara Abdollahi
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 304 : 785 - 792
  • [22] Evaluation of a Patient-Specific Respiratory Motion Model in Thoracic and Abdominal Phantom and Patient CT Images
    Liu, F.
    Zhang, Q.
    Hu, Y.
    Goodman, K.
    Mageras, G.
    MEDICAL PHYSICS, 2012, 39 (06) : 3912 - 3912
  • [23] Design and fabrication of indigenous multi-rotational thorax phantom for patient-specific quality assurance of IMRT and VMAT
    Kesavan, G.
    Senthilkumar, S.
    Hariprasanth, K.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2022, 177 (5-6): : 575 - 589
  • [24] Radiation Doses in Routine CT Examinations for Adult Patients in Saudi Arabia: A Systematic Review
    Alenazi, Khaled
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [25] EVALUATION OF ORGAN DOSES IN ADULT AND PAEDIATRIC CT EXAMINATIONS BASED ON MONTE CARLO SIMULATIONS AND IN-PHANTOM DOSIMETRY
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Takahashi, K.
    Obara, S.
    Akahane, K.
    Satake, M.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 166 - 171
  • [26] Evaluation of Four Commercial Dosimetry Systems for Routine Patient-Specific Tomotherapy Delivery Quality Assurance
    Xing, A.
    Arumugam, S.
    Deshpande, S.
    George, A.
    Holloway, L.
    Vial, P.
    Goozee, G.
    MEDICAL PHYSICS, 2014, 41 (06) : 319 - +
  • [27] Development of in-house heterogeneous thorax phantom and evaluation of pretreatment patient-specific transit dosimetry for intensity-modulated radiotherapy and volumetric modulated arc therapy plans
    Bagdare, Priyusha
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2022, 18 (04) : 1098 - 1104
  • [28] A Novel Method for Patient-Specific Tetrahedral Mesh Phantom Generation with Applications to Organ Dosimetry Following Radiotherapy
    Dawson, R. J.
    Reiners, K. A. M.
    Smither, W.
    Choi, C.
    Johnson, P. B.
    Bolch, W. E.
    MEDICAL PHYSICS, 2024, 51 (10) : 7940 - 7940
  • [29] Patient-specific radiation dose and cancer risk in computed tomography examinations in Ondo, Nigeria
    Olaniyan T.A.
    Aborisade C.A.
    Balogun F.A.
    Ogunsina S.A.
    Saidu A.
    Ibrahim M.B.
    Iranian Journal of Medical Physics, 2019, 16 (01) : 85 - 90
  • [30] A patient-specific hybrid phantom for calculating radiation dose and equivalent dose to the whole body
    Kollitz, Erika
    Han, Haegin
    Kim, Chan Hyeong
    Pinto, Marco
    Schwarz, Marco
    Riboldi, Marco
    Kamp, Florian
    Belka, Claus
    Newhauser, Wayne
    Dedes, George
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (03):