Experimental Study of Concrete Columns Reinforced with Lap-Spliced Glass Fiber-Reinforced Polymer Bars under Seismic Load

被引:0
|
作者
Tehrani, Bahareh Nader [1 ]
Farghaly, Ahmed Sabry [1 ,2 ]
Benmokrane, Brahim [3 ]
机构
[1] Univ Sherbrooke, Dept Civil & Bldg Engn, Sherbrooke, PQ, Canada
[2] Assiut Univ, Dept Civil Engn, Assiut, Egypt
[3] Univ Sherbrooke, Dept Civil & Bldg Engn, Tier 1 Canada Res Chair Adv Compos Mat Civil Struc, Sherbrooke, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
concrete columns; design codes; design recommendations; glass fiber-reinforced polymer (GFRP) bars; hysteresis response; lap splice; reversed cyclic loading; seismic performance; BOND STRENGTH; DURABILITY; BEHAVIOR;
D O I
10.14359/51740460
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
While reinforcing bar lap splicing is inevitable in reinforced concrete (RC) structures, it critically affects structural behavior, especially in structures subjected to seismic load. That notwithstanding, current North American design standards do not provide any recommendations or equations for lap -spliced glass fiber -reinforced polymer (GFRP) reinforcing bars under seismic load. This study tested six full-scale RC columns measuring 1850 mm (73 in.) in height and 400 x 400 mm (16 x 16 in.) in cross section under constant axial load and incremental reversed cyclic lateral loading. Four columns were reinforced with GFRP bars, and two were reinforced with steel bars for comparison. The test parameters included lap -splice length and type of reinforcement. The structural performance of the specimens was evaluated based on the cracking behavior, failure mechanism, hysteretic response, load -carrying capacity, dissipated energy, stiffness degradation, and strain behavior. Afterward, available models in North American design standards for the splice length of GFRP reinforcing bars under monotonic loading were evaluated based on the experimental results. According to the results, providing adequate splice length can secure satisfactory structural performance in spliced GFRP-RC columns. The splice length determined based on the North American design standards for monotonic loading cannot, however, be directly used to achieve the required drift capacity in GFRP-RC columns under reversed cyclic lateral loading.
引用
收藏
页码:69 / 82
页数:14
相关论文
共 50 条
  • [31] Proposed Design Equations for Lap Splice of Glass Fiber-Reinforced Polymer Bars under Compression in Concrete
    Kashani, Amirhomayoon Tabatabaei
    Mohamed, Hamdy M.
    Eslami, Abolfazl
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2020, 117 (02) : 291 - 302
  • [32] Seismic fragility analysis of lap-spliced reinforced concrete columns retrofitted by SMA wire jackets
    Choi, Eunsoo
    Park, Sun-Hee
    Chung, Young-Soo
    Kim, Hee Sun
    SMART MATERIALS AND STRUCTURES, 2013, 22 (08)
  • [33] Behavior of Full-Scale Glass Fiber-Reinforced Polymer Reinforced Concrete Columns under Axial Load
    De Luca, Antonio
    Matta, Fabio
    Nanni, Antonio
    ACI STRUCTURAL JOURNAL, 2010, 107 (05) : 589 - 596
  • [34] RETROFIT OF SLENDER SQUARE REINFORCED CONCRETE COLUMNS WITH GLASS FIBER-REINFORCED POLYMER FOR SEISMIC RESISTANCE
    Eshghi, S.
    Zanjanizadeh, V.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION B-ENGINEERING, 2008, 32 (5B): : 437 - 450
  • [35] Experiments on Seismic Behavior of Rectangular Glass Fiber-reinforced Polymer-reinforced Concrete Columns
    Deng Z.
    Gao L.
    Wang X.
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2019, 27 (05): : 1065 - 1076
  • [37] Strength Model for Concrete Columns Reinforced with Fiber-Reinforced Polymer Bars and Ties
    Tobbi, Hany
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2014, 111 (04) : 789 - 798
  • [38] Design for slenderness in concrete columns internally reinforced with fiber-reinforced polymer bars
    Mirmiran, A
    Yuan, WQ
    Chen, XB
    ACI STRUCTURAL JOURNAL, 2001, 98 (01) : 116 - 125
  • [39] Shear Behavior of Precast Concrete Box Culverts Reinforced with Glass Fiber-Reinforced Polymer Bars under Concentrated Load
    Elnady, Ahmed
    Mousa, Salaheldin
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2024, 121 (03) : 173 - 186
  • [40] Seismic resistance of square concrete columns retrofitted with glass fiber-reinforced polymer
    Memon, MS
    Sheikh, SA
    ACI STRUCTURAL JOURNAL, 2005, 102 (05) : 774 - 783