Experimental Study of Concrete Columns Reinforced with Lap-Spliced Glass Fiber-Reinforced Polymer Bars under Seismic Load

被引:0
|
作者
Tehrani, Bahareh Nader [1 ]
Farghaly, Ahmed Sabry [1 ,2 ]
Benmokrane, Brahim [3 ]
机构
[1] Univ Sherbrooke, Dept Civil & Bldg Engn, Sherbrooke, PQ, Canada
[2] Assiut Univ, Dept Civil Engn, Assiut, Egypt
[3] Univ Sherbrooke, Dept Civil & Bldg Engn, Tier 1 Canada Res Chair Adv Compos Mat Civil Struc, Sherbrooke, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
concrete columns; design codes; design recommendations; glass fiber-reinforced polymer (GFRP) bars; hysteresis response; lap splice; reversed cyclic loading; seismic performance; BOND STRENGTH; DURABILITY; BEHAVIOR;
D O I
10.14359/51740460
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
While reinforcing bar lap splicing is inevitable in reinforced concrete (RC) structures, it critically affects structural behavior, especially in structures subjected to seismic load. That notwithstanding, current North American design standards do not provide any recommendations or equations for lap -spliced glass fiber -reinforced polymer (GFRP) reinforcing bars under seismic load. This study tested six full-scale RC columns measuring 1850 mm (73 in.) in height and 400 x 400 mm (16 x 16 in.) in cross section under constant axial load and incremental reversed cyclic lateral loading. Four columns were reinforced with GFRP bars, and two were reinforced with steel bars for comparison. The test parameters included lap -splice length and type of reinforcement. The structural performance of the specimens was evaluated based on the cracking behavior, failure mechanism, hysteretic response, load -carrying capacity, dissipated energy, stiffness degradation, and strain behavior. Afterward, available models in North American design standards for the splice length of GFRP reinforcing bars under monotonic loading were evaluated based on the experimental results. According to the results, providing adequate splice length can secure satisfactory structural performance in spliced GFRP-RC columns. The splice length determined based on the North American design standards for monotonic loading cannot, however, be directly used to achieve the required drift capacity in GFRP-RC columns under reversed cyclic lateral loading.
引用
收藏
页码:69 / 82
页数:14
相关论文
共 50 条
  • [21] On lap splice length of lap-spliced crossties for reinforced concrete columns under cyclic loading
    Lee, Tai-Kuang
    Chen, Cheng-Cheng
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (12) : 2669 - 2678
  • [22] Strength of rectangular concrete columns reinforced with fiber-reinforced polymer bars
    Choo, CC
    Harik, IE
    Gesund, H
    ACI STRUCTURAL JOURNAL, 2006, 103 (03) : 452 - 459
  • [23] Strength of rectangular concrete columns reinforced with fiber-reinforced polymer bars
    Kentucky Transportation Center, Department of Civil Engineering, University of Kentucky, Lexington, KY, United States
    不详
    ACI Struct J, 2006, 3 (452-459):
  • [24] Failure Envelope of Circular Concrete Columns Reinforced with Glass Fiber-Reinforced Polymer Bars and Spirals
    Hadhood, Abdeldayem
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2017, 114 (06) : 1417 - 1428
  • [25] Effects of eccentric loading on performance of concrete columns reinforced with glass fiber-reinforced polymer bars
    Mahmoudabadi, Nasim Shakouri
    Bahrami, Alireza
    Saghir, Saba
    Ahmad, Afaq
    Iqbal, Muhammad
    Elchalakani, Mohamed
    Ozkilic, Yasin Onuralp
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [26] Proposed Flexural Stiffness of Slender Concrete Columns Reinforced with Glass Fiber-Reinforced Polymer Bars
    Abdelazim, Waseem
    Mohamed, Hamdy M.
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2021, 118 (01) : 227 - 240
  • [27] Effects of eccentric loading on performance of concrete columns reinforced with glass fiber-reinforced polymer bars
    Nasim Shakouri Mahmoudabadi
    Alireza Bahrami
    Saba Saghir
    Afaq Ahmad
    Muhammad Iqbal
    Mohamed Elchalakani
    Yasin Onuralp Özkılıç
    Scientific Reports, 14
  • [28] Experimental Study on the Flexural Behavior of Lap-Spliced Ultra-High-Performance Fiber-Reinforced Concrete Beams
    Bae, Baek-Il
    Choi, Hyun-Ki
    POLYMERS, 2022, 14 (11)
  • [29] Lap Splice Length Equation of Glass Fiber-Reinforced Polymer Bars in Flexural Reinforced Concrete Members
    Ortiz, Jesus D.
    Benmokrane, Brahim
    Nanni, Antonio
    ACI STRUCTURAL JOURNAL, 2025, 122 (02) : 175 - 188
  • [30] Behavior of Hollow Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns under Axial Load: Experimental and Theoretical Investigation
    Gouda, Mohammed Gamal
    Mohamed, Hamdy M.
    Manalo, Allan C.
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2022, 119 (06) : 289 - 302