Experimental Study of Concrete Columns Reinforced with Lap-Spliced Glass Fiber-Reinforced Polymer Bars under Seismic Load

被引:0
|
作者
Tehrani, Bahareh Nader [1 ]
Farghaly, Ahmed Sabry [1 ,2 ]
Benmokrane, Brahim [3 ]
机构
[1] Univ Sherbrooke, Dept Civil & Bldg Engn, Sherbrooke, PQ, Canada
[2] Assiut Univ, Dept Civil Engn, Assiut, Egypt
[3] Univ Sherbrooke, Dept Civil & Bldg Engn, Tier 1 Canada Res Chair Adv Compos Mat Civil Struc, Sherbrooke, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
concrete columns; design codes; design recommendations; glass fiber-reinforced polymer (GFRP) bars; hysteresis response; lap splice; reversed cyclic loading; seismic performance; BOND STRENGTH; DURABILITY; BEHAVIOR;
D O I
10.14359/51740460
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
While reinforcing bar lap splicing is inevitable in reinforced concrete (RC) structures, it critically affects structural behavior, especially in structures subjected to seismic load. That notwithstanding, current North American design standards do not provide any recommendations or equations for lap -spliced glass fiber -reinforced polymer (GFRP) reinforcing bars under seismic load. This study tested six full-scale RC columns measuring 1850 mm (73 in.) in height and 400 x 400 mm (16 x 16 in.) in cross section under constant axial load and incremental reversed cyclic lateral loading. Four columns were reinforced with GFRP bars, and two were reinforced with steel bars for comparison. The test parameters included lap -splice length and type of reinforcement. The structural performance of the specimens was evaluated based on the cracking behavior, failure mechanism, hysteretic response, load -carrying capacity, dissipated energy, stiffness degradation, and strain behavior. Afterward, available models in North American design standards for the splice length of GFRP reinforcing bars under monotonic loading were evaluated based on the experimental results. According to the results, providing adequate splice length can secure satisfactory structural performance in spliced GFRP-RC columns. The splice length determined based on the North American design standards for monotonic loading cannot, however, be directly used to achieve the required drift capacity in GFRP-RC columns under reversed cyclic lateral loading.
引用
收藏
页码:69 / 82
页数:14
相关论文
共 50 条
  • [1] Seismic upgrade with carbon fiber-reinforced polymer of columns containing lap-spliced reinforcing bars
    Ghosh, Kumar K.
    Sheikh, Shamim A.
    [J]. ACI STRUCTURAL JOURNAL, 2007, 104 (02) : 227 - 236
  • [2] Experimental Study on Seismic Behavior of Concrete Columns Reinforced with Glass Fiber-Reinforced Polymer Bars
    Souza, W. M.
    Correia, J. R.
    Firmo, J. P.
    Almeida, J.
    Rosa, I. C.
    Correia, A. A.
    [J]. ACI STRUCTURAL JOURNAL, 2024, 121 (04) : 131 - 148
  • [3] Seismic design criteria for circular lap-spliced reinforced concrete bridge columns retrofitted with fiber-reinforced polymer jackets
    Elsanadedy, HM
    Haroun, MA
    [J]. ACI STRUCTURAL JOURNAL, 2005, 102 (03) : 354 - 362
  • [4] Effect of Axial Load and Steel Fibers on the Seismic Behavior of Lap-Spliced Glass Fiber Reinforced Polymer-Reinforced Concrete Rectangular Columns
    Naqvi, Syed
    Mahmoud, Karam
    El-Salakawy, Ehab
    [J]. ENGINEERING STRUCTURES, 2017, 134 : 376 - 389
  • [5] Experimental Study on Deformation and Failure of Circular Concrete Columns Reinforced with Glass Fiber-Reinforced Polymer Bars
    Liu, Jun
    Du, Hongkai
    Zhou, Hong
    Nan, Zhiling
    Nie, Pingjun
    [J]. ACI STRUCTURAL JOURNAL, 2019, 116 (04) : 45 - 52
  • [6] Experimental Investigations of Reinforced Concrete Columns with Lap-Spliced Crossties Under Cyclic Axial and Lateral Load
    Lee, Tai-Kuang
    Chen, Cheng-Cheng
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2024, 34 (01) : 128 - 140
  • [7] Concrete Columns Reinforced Longitudinally and Transversally with Glass Fiber-Reinforced Polymer Bars
    Tobbi, Hany
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    [J]. ACI STRUCTURAL JOURNAL, 2012, 109 (04) : 551 - 558
  • [8] Experimental Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns under Lateral Cyclic Load
    Elshamandy, Mohammed G.
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    [J]. ACI STRUCTURAL JOURNAL, 2018, 115 (02) : 337 - 349
  • [9] Flexural ductility of reinforced concrete beams with lap-spliced bars
    Rakhshanimehr, Mehrollah
    Esfahani, M. Reza
    Kianoush, M. Reza
    Mohammadzadeh, B. Ali
    Mousavi, S. Roohollah
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 2014, 41 (07) : 594 - 604
  • [10] Seismic Behavior of High-Strength Concrete Circular Columns Reinforced with Glass Fiber-Reinforced Polymer Bars
    Abdallah, Amr E.
    El-Salakawy, Ehab F.
    [J]. ACI STRUCTURAL JOURNAL, 2021, 118 (05) : 221 - 234