Effects of Simulated Gastric Juice on CAD/CAM Resin CompositesMorphological and Mechanical Evaluations

被引:39
|
作者
Backer, Adriana D. [1 ,2 ]
Munchow, Eliseu A. [1 ,3 ]
Eckert, George J. [4 ]
Hara, Anderson T. [5 ]
Platt, Jeffrey A. [1 ]
Bottino, Marco C. [1 ]
机构
[1] Indiana Univ, Sch Dent, Div Dent Biomat, Dept Biomed & Appl Sci, Indianapolis, IN USA
[2] IUSD, Grad Prosthodont, Dept Prosthodont, Indianapolis, IN USA
[3] Univ Fed Pelotas, Sch Dent, Dept Operat Dent, Pelotas, Brazil
[4] Indiana Univ Sch Med, Dept Biostat, Indianapolis, IN 46202 USA
[5] IUSD, Dept Cariol Operat Dent & Dent Publ Hlth, Indianapolis, IN USA
关键词
CAD/CAM; Resin composites; Roughness; Hardness; Acid degradation; Bulimia; AESTHETIC RESTORATIVE MATERIALS; WATER SORPTION CHARACTERISTICS; SURFACE-ROUGHNESS; COMPOSITE RESIN; DENTAL EROSION; STORAGE TIME; DEGRADATION; RESISTANCE; FOOD; PH;
D O I
10.1111/jopr.12420
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the effects of simulated gastric juice on CAD/CAM resin composites by means of morphological and mechanical (i.e., hardness) evaluations. Materials and Methods: Fourteen specimens of each resin composite (Lava Ultimate and Paradigm MZ100) were prepared according to the manufacturer's instructions. They were submitted to erosive challenges in a simulated gastric juice (pH = 1.2) solution for 6 and 24 hours. Vickers microhardness and surface roughness (R-a, R-q) evaluations were taken before (baseline) and after acid exposure. Morphological analysis was obtained using scanning electron microscopy (SEM). Statistical analysis was performed using two-way repeated measures ANOVA and Student-Newman-Keuls's test (alpha = 0.05). Results: Paradigm MZ100 demonstrated higher microhardness than Lava Ultimate regardless of the storage time period (p <= 0.001), and microhardness was not affected by the acidic challenge (p = 0.58). After 6 hours of acid exposure, a significant decrease in R-a and R-q was seen for Paradigm MZ100 when compared to the baseline (R(a)p = 0.032; R(q)p = 0.013); however, for Lava Ultimate only Rq decreased (p = 0.021), while R-a remained unchanged (p = 0.38). After 24 hours of acid exposure, while Paradigm MZ100 exhibited no additional changes in surface roughness (p >= 0.75), Lava Ultimate became rougher (R(a)p = 0.041; R(q)p = 0.014), as confirmed by SEM imaging. Conclusions: The acidic scenario tested in the present study changed the surface roughness of the resin composites but not their Vickers microhardness. Moreover, both resin composites seem suitable for use under acidic scenarios, although Paradigm MZ100 showed enhanced stability compared to Lava Ultimate.
引用
收藏
页码:424 / 431
页数:8
相关论文
共 50 条
  • [21] Influence of Artificial Aging on Mechanical Properties of Six Resin Composite Blocks for CAD/CAM Application
    Grzebieluch, Wojciech
    Kowalewski, Piotr
    Sopel, Miroslaw
    Mikulewicz, Marcin
    COATINGS, 2022, 12 (06)
  • [22] Mechanical Properties, Wear Resistance, and Reliability of Two CAD-CAM Resin Matrix Ceramics
    Silva, Ebele Adaobi
    Simionato, Anselmo Agostinho
    Faria, Adriana Claudia Lapria
    Bonfante, Estevam Augusto
    Rodrigues, Renata Cristina Silveira
    Ribeiro, Ricardo Faria
    MEDICINA-LITHUANIA, 2023, 59 (01):
  • [23] Mechanical properties of resin-ceramic CAD-CAM materials after accelerated aging
    Blackburn, Caleb
    Rask, Hailee
    Awada, Abdallah
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (06): : 954 - 958
  • [24] Simulated fatigue resistance of composite resin versus porcelain CAD/CAM overlay restorations on endodontically treated molars
    Magne, Pascal
    Knezevic, Alena
    QUINTESSENCE INTERNATIONAL, 2009, 40 (02): : 125 - 133
  • [25] The influence of FRCs reinforcement on marginal adaptation of CAD/CAM composite resin endocrowns after simulated fatigue loading
    Rocca, Giovanni Tommaso
    Saratti, Carlo Massimo
    Poncet, Antoine
    Feilzer, Albert J.
    Krejci, Ivo
    ODONTOLOGY, 2016, 104 (02) : 220 - 232
  • [26] The influence of FRCs reinforcement on marginal adaptation of CAD/CAM composite resin endocrowns after simulated fatigue loading
    Giovanni Tommaso Rocca
    Carlo Massimo Saratti
    Antoine Poncet
    Albert J. Feilzer
    Ivo Krejci
    Odontology, 2016, 104 : 220 - 232
  • [27] Effect of Simulated Gastric Acid on Aesthetical Restorative CAD-CAM Materials' Microhardness and Flexural Strength
    Gulakar, T. L.
    Comert, G. N.
    Karaman, E.
    Cakan, U.
    Ozel, G. S.
    Ahmet, S. O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (10) : 1505 - 1511
  • [28] Influence of mechanical and chemical degradation on surface gloss of direct and CAD-CAM resin composite materials
    Ardu, Stefano
    Daher, Rene
    Di Bella, Enrico
    Rossier, Isaline
    Krejci, Ivo
    AMERICAN JOURNAL OF DENTISTRY, 2020, 33 (03): : 157 - 160
  • [29] EFFECTS OF THERMAL AGEING ON THE MECHANICAL PROPERTIES OF CAD-CAM CERAMIC MATERIALS
    Turker, Izim
    Kursoglu, Pinar
    CERAMICS-SILIKATY, 2023, 67 (04) : 496 - 504
  • [30] Effects of Different Storage Conditions on Mechanical Properties of CAD/CAM Restorative Materials
    Atay, Ayse
    Sagirkaya, Elcin
    ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2020, 22 (02) : 83 - 96