Mechanical properties of resin-ceramic CAD-CAM materials after accelerated aging

被引:40
|
作者
Blackburn, Caleb [1 ]
Rask, Hailee [1 ]
Awada, Abdallah [2 ]
机构
[1] Louisiana State Univ, Sch Dent, New Orleans, LA 70119 USA
[2] Louisiana State Univ, Sch Dent, Dept Prosthodont, 1100 Florida Ave,Box 222, New Orleans, LA 70119 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2018年 / 119卷 / 06期
关键词
RESTORATIVE MATERIALS; LITHIUM DISILICATE; NETWORK MATERIAL; COMPOSITE RESIN; WEAR PROPERTIES; HUMAN ENAMEL; STRENGTH; ZIRCONIA; SYSTEMS; COLOR;
D O I
10.1016/j.prosdent.2017.08.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The development of polymer-based computer-aided design and computer-aided manufacturing (CAD-CAM) milling bocks and the limited availability of independent studies on these materials make it pertinent to evaluate changes in their mechanical properties after simulated aging to identify strengths and limitations. Purpose. The purpose of this in vitro study was to measure the effect of thermocycling on the flexural properties of ceramic, resin, and resin-ceramic CAD-CAM materials. Material and methods. Studied materials included Lava Ultimate Restorative (LVU; 3M ESPE), Enamic (ENA; VITA Zahnfabrik), Vitablocs Mark II (VM2; VITA Zahnfabrik), and Paradigm MZ100 (MZ1; 3M ESPE). Polished 4x1.2x14 mm bars (n=45 per material) were prepared from standard-size milling blocks. The 2 distilled water baths of the thermocycling apparatus were set to 5 degrees C and 55 degrees C, with a specimen immersion time of 15 seconds and transfer time of 4 seconds. Fifteen specimens from each material group were subjected to a 3-point flexural test at 3 different thermocycling intervals: 0 (control), 5000, and 10 000 cycles. The flexural test was performed over a 12-mm span with a crosshead speed of 0.5 mm/min. Data were subjected to multiple analyses of variance and the Tukey HSD post hoc tests (alpha=.05). Results. Mean flexural strength values for 0, 5000, and 10 000 cycles were 133, 130, and 128 MPa for VM2; 175, 139, and 134 MPa for LVU; 154, 144, and 138 MPa for MZ1; and 149, 136, and 132 MPa for ENA. Mean flexural modulus values were 51, 52, and 54 GPa for VM2; 14, 13, and 13 GPa for LVU; 16,15, and 15 GPa for MZ1; and 31, 30, and 31 GPa for ENA. Mean modulus of resilience values were 0.17,0.16, and 0.15 MPa for VM2; 10.1, 0.76, and 0.72 MPa for LVU; 0.77, 0.69, and 0.62 MPa for MZ1; and 0.42, 0.31, and 0.28 MPa for ENA. A significant difference was found among the materials in the mean change of flexural strength (P<.001) and modulus of resilience (P<.05) after thermocycling. No significant difference was found among the materials in the mean change of flexural modulus after thermocycling (P=.113). Conclusions. The mean flexural strength of resin-ceramics is significantly different from that of the feldspathic ceramic control at 0 and 5000 cycles, but not at 10 000 cycles. The mean modulus of resilience of resin-ceramics varies significantly after thermocycling, unlike the feldspathic ceramic control. Conversely, the mean flexural modulus of tested materials did not vary significantly after thermocycling.
引用
收藏
页码:954 / 958
页数:5
相关论文
共 50 条
  • [1] Mechanical properties of resin-ceramic CAD/CAM restorative materials
    Awada, Abdallah
    Nathanson, Dan
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04): : 587 - 593
  • [2] CAD-CAM resin-ceramic material wear: A systematic review
    Laborie, Marion
    Naveau, Adrien
    Menard, Aude
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (05): : 812 - 818
  • [3] EFFECTS OF THERMAL AGEING ON THE MECHANICAL PROPERTIES OF CAD-CAM CERAMIC MATERIALS
    Turker, Izim
    Kursoglu, Pinar
    CERAMICS-SILIKATY, 2023, 67 (04) : 496 - 504
  • [4] Change in Color and Gloss Parameters of Stained Monolithic Resin-Ceramic CAD/CAM Materials After Simulated Aging: An In Vitro Study
    Muhlemann, Sven
    Stromeyer, Sofia
    Ioannidis, Alexis
    Attin, Thomas
    Hammerle, Christoph Hf
    Ozcan, Mutlu
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (01) : 79 - 87
  • [5] Effect of different polishing techniques on surface properties and bacterial adhesion on resin-ceramic CAD/CAM materials
    Ozarslan, Merve
    Bilgili Can, Dilber
    Avcioglu, Nermin Hande
    Caliskan, Secil
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (08) : 5289 - 5299
  • [6] Effect of different polishing techniques on surface properties and bacterial adhesion on resin-ceramic CAD/CAM materials
    Merve Özarslan
    Dilber Bilgili Can
    Nermin Hande Avcioglu
    Seçil Çalışkan
    Clinical Oral Investigations, 2022, 26 : 5289 - 5299
  • [7] Effect of Aging on Stained Monolithic Resin-Ceramic CAD/CAM Materials: Quantitative and Qualitative Analysis of Surface Roughness
    Muhlemann, Sven
    Bernini, Joelle M.
    Sener, Beatrice
    Hammerle, Christoph H. F.
    Ozcan, Mutlu
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E563 - E571
  • [8] Influence of different glaze firing protocols on the mechanical properties of CAD-CAM ceramic materials
    Zaniboni, Joissi Ferrari
    Silva, Aryvelto Miranda
    Alencar, Cristiane de Melo
    Porto, Thiago Soares
    Jasinevicius, Renato Goulart
    Fortulan, Carlos Alberto
    de Campos, Edson Alves
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (06): : 925.e1 - 925.e8
  • [9] Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after aging
    Rizzatto, Laura Vitoria
    Meneghetti, Daniel
    Di Domenico, Marielle
    Facenda, Julia Cadorin
    Weber, Katia Raquel
    Corazza, Pedro Henrique
    Borba, Marcia
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (03): : 136 - 144
  • [10] Adhesive Bond Strength of Resin Cements to CAD-CAM Hybrid Ceramic Materials
    Maawadh, Ahmed Mohammed
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (02): : 438 - 444