Autofluorescence lifetime flow cytometry with time-correlated single photon counting

被引:2
|
作者
Samimi, Kayvan [1 ]
Pasachhe, Ojaswi [1 ]
Guzman, Emmanuel Contreras [1 ]
Riendeau, Jeremiah [1 ]
Gillette, Amani A. [1 ]
Pham, Dan L. [2 ]
Wiech, Kasia J. [2 ]
Moore, Darcie L. [3 ]
Skala, Melissa C. [1 ,2 ]
机构
[1] Morgridge Inst Res, Madison, WI 53715 USA
[2] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[3] Univ Wisconsin, Dept Neurosci, Madison, WI 53705 USA
基金
美国国家卫生研究院;
关键词
flow cytometry; fluorescence lifetime; label-free sensing; metabolism; NAD(P)H; single-cell analysis; time tagger; FLUORESCENCE-LIFETIME; MICROSCOPY; NADH; QUIESCENCE; NAD(P)H; CELLS;
D O I
10.1002/cyto.a.24883
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Autofluorescence lifetime imaging microscopy (FLIM) is sensitive to metabolic changes in single cells based on changes in the protein-binding activities of the metabolic co-enzymes NAD(P)H. However, FLIM typically relies on time-correlated single-photon counting (TCSPC) detection electronics on laser-scanning microscopes, which are expensive, low-throughput, and require substantial post-processing time for cell segmentation and analysis. Here, we present a fluorescence lifetime-sensitive flow cytometer that offers the same TCSPC temporal resolution in a flow geometry, with low-cost single-photon excitation sources, a throughput of tens of cells per second, and real-time single-cell analysis. The system uses a 375 nm picosecond-pulsed diode laser operating at 50 MHz, alkali photomultiplier tubes, an FPGA-based time tagger, and can provide real-time phasor-based classification (i.e., gating) of flowing cells. A CMOS camera produces simultaneous brightfield images using far-red illumination. A second PMT provides two-color analysis. Cells are injected into the microfluidic channel using a syringe pump at 2-5 mm/s with nearly 5 ms integration time per cell, resulting in a light dose of 2.65 J/cm2 that is well below damage thresholds (25 J/cm2 at 375 nm). Our results show that cells remain viable after measurement, and the system is sensitive to autofluorescence lifetime changes in Jurkat T cells with metabolic perturbation (sodium cyanide), quiescent versus activated (CD3/CD28/CD2) primary human T cells, and quiescent versus activated primary adult mouse neural stem cells, consistent with prior studies using multiphoton FLIM. This TCSPC-based autofluorescence lifetime flow cytometer provides a valuable label-free method for real-time analysis of single-cell function and metabolism with higher throughput than laser-scanning microscopy systems.
引用
收藏
页码:607 / 620
页数:14
相关论文
共 50 条
  • [41] Monolithic Time-to-Digital Converter chips for Time-Correlated Single-Photon Counting and Fluorescence Lifetime measurements
    Markovic, Bojan
    Tamborini, Davide
    Bellisai, Simone
    Bassi, Andrea
    Pifferi, Antonio
    Villa, Federica
    Padovini, Giorgio Michele
    Tosi, Alberto
    QUANTUM SENSING AND NANOPHOTONIC DEVICES X, 2013, 8631
  • [42] Wide-field time-correlated single-photon counting (TCSPC) lifetime microscopy with microsecond time resolution
    Hirvonen, Liisa M.
    Festy, Frederic
    Suhling, Klaus
    OPTICS LETTERS, 2014, 39 (19) : 5602 - 5605
  • [43] Afterpulse Background Suppression in Time-Correlated Single Photon Counting Lifetime Experiments using Optimized Gate Filter
    Gerber, Martin
    Kleiman, Rafael
    2014 IEEE 40TH PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2014, : 1899 - 1902
  • [44] Wide-field time-correlated single photon counting-based fluorescence lifetime imaging microscopy
    Suhling, Klaus
    Hirvonen, Liisa M.
    Becker, Wolfgang
    Smietana, Stefan
    Netz, Holger
    Milnes, James
    Conneely, Thomas
    Le Marois, Alix
    Jagutzki, Ottmar
    Festy, Fred
    Petrasek, Zdenek
    Beeby, Andrew
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 942
  • [45] Study of photoluminescence decay by time-correlated single photon counting for the determination of the minority-carrier lifetime in silicon
    Parola, Stephanie
    Daanoune, Mehdi
    Focsa, Alexandru
    Semmache, Bachir
    Picard, Erwann
    Kaminski-Cachopo, Anne
    Lemiti, Mustapha
    Blanc-Pelissier, Daniele
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON CRYSTALLINE SILICON PHOTOVOLTAICS (SILICONPV 2014), 2014, 55 : 121 - 127
  • [46] Improving the counting efficiency in time-correlated single photon counting experiments by dead-time optimization
    Peronio, P.
    Acconcia, G.
    Rech, I.
    Ghioni, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (11):
  • [47] Time-of-flight sensing using time-correlated single-photon counting
    Buller, Gerald S.
    McCarthy, Aongus
    Collins, Robert J.
    Hiskett, Philip A.
    Fernandez, Veronica
    Hemandez-Marin, Sergio
    Wallace, Andrew M.
    QUANTUM SENSING AND NANOPHOTONIC DEVICES V, 2008, 6900
  • [48] TIME-CORRELATED SINGLE-PHOTON COUNTING RANGE PROFILING OF MOVING OBJECTS
    Hedborg, Julia
    Jonsson, Per
    Henriksson, Markus
    Sjoqvist, Lars
    27TH INTERNATIONAL LASER RADAR CONFERENCE (ILRC 27), 2016, 119
  • [49] Processing time-correlated single photon counting data to acquire range images
    Umasuthan, M
    Wallace, AM
    Massa, JS
    Buller, GS
    Walker, AC
    IEE PROCEEDINGS-VISION IMAGE AND SIGNAL PROCESSING, 1998, 145 (04): : 237 - 243
  • [50] Bunch fill pattern at BESSY monitored by time-correlated single photon counting
    Holldack, Karsten
    von Hartrott, Michael
    Hoeft, Frank
    Neitzke, Oliver
    Bauch, Erik
    Wahl, Michael
    ADVANCED PHOTON COUNTING TECHNIQUES II, 2007, 6771