Autofluorescence lifetime flow cytometry with time-correlated single photon counting

被引:2
|
作者
Samimi, Kayvan [1 ]
Pasachhe, Ojaswi [1 ]
Guzman, Emmanuel Contreras [1 ]
Riendeau, Jeremiah [1 ]
Gillette, Amani A. [1 ]
Pham, Dan L. [2 ]
Wiech, Kasia J. [2 ]
Moore, Darcie L. [3 ]
Skala, Melissa C. [1 ,2 ]
机构
[1] Morgridge Inst Res, Madison, WI 53715 USA
[2] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[3] Univ Wisconsin, Dept Neurosci, Madison, WI 53705 USA
基金
美国国家卫生研究院;
关键词
flow cytometry; fluorescence lifetime; label-free sensing; metabolism; NAD(P)H; single-cell analysis; time tagger; FLUORESCENCE-LIFETIME; MICROSCOPY; NADH; QUIESCENCE; NAD(P)H; CELLS;
D O I
10.1002/cyto.a.24883
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Autofluorescence lifetime imaging microscopy (FLIM) is sensitive to metabolic changes in single cells based on changes in the protein-binding activities of the metabolic co-enzymes NAD(P)H. However, FLIM typically relies on time-correlated single-photon counting (TCSPC) detection electronics on laser-scanning microscopes, which are expensive, low-throughput, and require substantial post-processing time for cell segmentation and analysis. Here, we present a fluorescence lifetime-sensitive flow cytometer that offers the same TCSPC temporal resolution in a flow geometry, with low-cost single-photon excitation sources, a throughput of tens of cells per second, and real-time single-cell analysis. The system uses a 375 nm picosecond-pulsed diode laser operating at 50 MHz, alkali photomultiplier tubes, an FPGA-based time tagger, and can provide real-time phasor-based classification (i.e., gating) of flowing cells. A CMOS camera produces simultaneous brightfield images using far-red illumination. A second PMT provides two-color analysis. Cells are injected into the microfluidic channel using a syringe pump at 2-5 mm/s with nearly 5 ms integration time per cell, resulting in a light dose of 2.65 J/cm2 that is well below damage thresholds (25 J/cm2 at 375 nm). Our results show that cells remain viable after measurement, and the system is sensitive to autofluorescence lifetime changes in Jurkat T cells with metabolic perturbation (sodium cyanide), quiescent versus activated (CD3/CD28/CD2) primary human T cells, and quiescent versus activated primary adult mouse neural stem cells, consistent with prior studies using multiphoton FLIM. This TCSPC-based autofluorescence lifetime flow cytometer provides a valuable label-free method for real-time analysis of single-cell function and metabolism with higher throughput than laser-scanning microscopy systems.
引用
收藏
页码:607 / 620
页数:14
相关论文
共 50 条
  • [31] Underwater Depth Imaging using Time-correlated Single Photon Counting
    Maccarone, Aurora
    McCarthy, Aongus
    Ren, Ximing
    Warburton, Ryan E.
    Wallace, Andy M.
    Moffat, James
    Petillot, Yvan
    Buller, Gerald S.
    ADVANCED PHOTON COUNTING TECHNIQUES IX, 2015, 9492
  • [32] Monitoring cellular mechanosensing using time-correlated single photon counting
    Tabouillot, Tristan
    Gullapalli, Ramachandra
    Butler, Peter J.
    ADVANCED PHOTON COUNTING TECHNIQUES, 2006, 6372
  • [33] TIME-CORRELATED SINGLE PHOTON-COUNTING WITH MICROCHANNEL PLATE DETECTORS
    CHANG, MC
    COURTNEY, SH
    CROSS, AJ
    GULOTTY, RJ
    PETRICH, JW
    FLEMING, GR
    ANALYTICAL INSTRUMENTATION, 1985, 14 (3-4): : 433 - 464
  • [34] Research on velocity measurement based on time-correlated single photon counting
    Yang J.
    Wang C.
    Qiao K.
    Tang M.
    Jin C.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (10):
  • [35] Dynamic time-correlated single-photon counting laser ranging
    Peng H.
    Wang Y.-R.
    Meng W.-D.
    Yan P.-Q.
    Li Z.-H.
    Li C.
    Pan H.-F.
    Wu G.
    Wang, Yu-rong (yrwang152@163.com), 2018, Springer Verlag (14): : 129 - 132
  • [36] PICOSECOND FLUORESCENCE SPECTROSCOPY BY TIME-CORRELATED SINGLE-PHOTON COUNTING
    KINOSHITA, S
    KUSHIDA, T
    ANALYTICAL INSTRUMENTATION, 1985, 14 (3-4): : 503 - 524
  • [37] Dynamic time-correlated single-photon counting laser ranging
    彭欢
    王煜蓉
    孟文东
    颜佩琴
    李召辉
    李辰
    潘海峰
    吴光
    OptoelectronicsLetters, 2018, 14 (02) : 129 - 132
  • [38] Time-correlated single photon counting FLIM: Some considerations for physiologists
    Medine, Claire N.
    McDonald, Angela
    Bergmann, Axel
    Duncan, Rory R.
    MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (05) : 420 - 425
  • [39] Time-correlated single-photon counting laser radar in turbulence
    Henriksson, Markus
    Sjoqvist, Lars
    TECHNOLOGIES FOR OPTICAL COUNTERMEASURES VIII, 2011, 8187
  • [40] Resolving sonoluminescence pulse width with time-correlated single photon counting
    Gompf, B
    Gunther, R
    Nick, G
    Pecha, R
    Eisenmenger, W
    PHYSICAL REVIEW LETTERS, 1997, 79 (07) : 1405 - 1408