A polarization-improved dual-beam spin-exchange relaxation-free magnetometer with reflection-assisted pumping

被引:2
|
作者
Huang, Binyue [1 ,7 ]
Liu, Ying [1 ,2 ,3 ,4 ,5 ]
Li, Renjie [1 ,4 ]
Li, Jiajie [1 ,4 ]
Tang, Junjian [1 ,4 ,8 ]
Zhai, Yueyang [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
[2] Beihang Univ, Inst Large scale Sci Facil, Beijing 100191, Peoples R China
[3] Beihang Univ, Ctr Zero Magnet Field Sci, Beijing 100191, Peoples R China
[4] Beihang Univ, Hangzhou Innovat Inst, Zhejiang Prov Key Lab Ultraweak Magnet Field Space, Hangzhou 310051, Peoples R China
[5] Natl Inst Extremely Weak Magnet Field Infrastruct, Hangzhou 310051, Peoples R China
[6] Hefei Natl Lab, Hefei 230088, Peoples R China
[7] Beihang Univ, Shen Yuan Honors Coll, Beijing 100191, Peoples R China
[8] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Reflective atomic magnetometer; Double-pass pumping; Optical polarization; Spin-exchange relaxation-free; High sensitivity; ATOMIC MAGNETOMETER;
D O I
10.1016/j.sna.2024.115523
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The highly sensitive SERF magnetometers hold exciting prospects for magnetocardiography and magnetoencephalography, and the accuracy of medical measurements depends largely on the performance of the magnetometers. A double -pass configuration is used to obtain uniform polarization and constructed by adding a mirror to retro -reflect the pump light. The transmission model of the reflected light which takes the effect of forward light into account is proposed, and the improved polarization is experimentally verified. The essential operation parameters of the magnetometer are optimized. The theoretical framework is established outlining the relationship between pump power, probe frequency, and signal response, and the optimal values for these parameters are experimentally determined. With the appropriate selection of probe power and operating temperature, the double -pass configuration achieves a sensitivity of 5.81 fT/Hz 1/2 , a bandwidth of 110 Hz, and represents a 17% improvement in stability compared to the single -pass configuration. The optimized magnetometer exhibits reduced susceptibility to laser conditions and enhanced stability, attributed to the reflection -assisted polarization improvement and better uniformity. This configuration efficiently utilizes the pumping laser, and its miniaturization offers significant benefits for magnetoencephalography and other biomagnetic measurements.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Experimental Investigation on Nonlinearity of Spin-Exchange Relaxation-Free Atomic Spin Gyroscope
    Chen Dongying
    Yang Yuanhong
    Wang Zhongliang
    Liu Feng
    Jiang Liwei
    Quan Wei
    Fang Jiancheng
    ACTA OPTICA SINICA, 2019, 39 (08)
  • [42] Investigation on Rotation Response of Spin-Exchange Relaxation-Free Atomic Spin Gyroscope
    Yang, Yuanhong
    Chen, Dongying
    Jin, Wei
    Quan, Wei
    Liu, Feng
    Fang, Jiancheng
    IEEE ACCESS, 2019, 7 : 148176 - 148182
  • [43] Spin dynamics of the potassium magnetometer in spin-exchange relaxation free regime
    伏吉庆
    杜鹏程
    周庆
    王如泉
    Chinese Physics B, 2016, (01) : 440 - 443
  • [44] Transverse light-shift in a spin-exchange relaxation-free co-magnetometer: measurement, decoupling, and suppression
    Liu, Sixun
    Wang, Ruigang
    Yuan, Linlin
    Wu, Jiaqi
    Yuan, Qi
    Zhu, Jun
    Fan, Wenfeng
    Wang, Zhuo
    Du, Pengcheng
    OPTICS EXPRESS, 2022, 30 (09) : 15310 - 15326
  • [45] Transverse relaxation determination based on light polarization modulation for spin-exchange relaxation free atomic magnetometer
    Liu, Xue-Jing
    Ding, Ming
    Li, Yang
    Hu, Yan-Hui
    Jin, Wei
    Fang, Jian-Cheng
    CHINESE PHYSICS B, 2018, 27 (07)
  • [46] Accuracy enhancement of magnetic field distribution measurements within a large cell spin-exchange relaxation-free magnetometer
    Gusarov, Alexander
    Baranga, Andrei Ben-Amar
    Levron, David
    Shuker, Reuben
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (04)
  • [47] Spin dynamics of the potassium magnetometer in spin-exchange relaxation free regime
    Fu, Ji-Qing
    Du, Peng-Cheng
    Zhou, Qing
    Wang, Ru-Quan
    CHINESE PHYSICS B, 2016, 25 (01)
  • [48] Transverse relaxation determination based on light polarization modulation for spin-exchange relaxation free atomic magnetometer
    刘学静
    丁铭
    李阳
    胡焱晖
    靳伟
    房建成
    Chinese Physics B, 2018, 27 (07) : 281 - 285
  • [49] Nonzero-Order Resonances in Single-Beam Spin-Exchange Relaxation-Free Magnetometers
    Wang, Kun
    Zhang, Kaixuan
    Xu, Nuozhou
    Yan, Yifan
    Li, Xiaoyu
    Zhou, Binquan
    PHOTONICS, 2023, 10 (04)
  • [50] Spin-exchange relaxation-free magnetometry using elliptically polarized light
    Shah, V.
    Romalis, M. V.
    PHYSICAL REVIEW A, 2009, 80 (01):