A polarization-improved dual-beam spin-exchange relaxation-free magnetometer with reflection-assisted pumping

被引:2
|
作者
Huang, Binyue [1 ,7 ]
Liu, Ying [1 ,2 ,3 ,4 ,5 ]
Li, Renjie [1 ,4 ]
Li, Jiajie [1 ,4 ]
Tang, Junjian [1 ,4 ,8 ]
Zhai, Yueyang [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
[2] Beihang Univ, Inst Large scale Sci Facil, Beijing 100191, Peoples R China
[3] Beihang Univ, Ctr Zero Magnet Field Sci, Beijing 100191, Peoples R China
[4] Beihang Univ, Hangzhou Innovat Inst, Zhejiang Prov Key Lab Ultraweak Magnet Field Space, Hangzhou 310051, Peoples R China
[5] Natl Inst Extremely Weak Magnet Field Infrastruct, Hangzhou 310051, Peoples R China
[6] Hefei Natl Lab, Hefei 230088, Peoples R China
[7] Beihang Univ, Shen Yuan Honors Coll, Beijing 100191, Peoples R China
[8] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Reflective atomic magnetometer; Double-pass pumping; Optical polarization; Spin-exchange relaxation-free; High sensitivity; ATOMIC MAGNETOMETER;
D O I
10.1016/j.sna.2024.115523
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The highly sensitive SERF magnetometers hold exciting prospects for magnetocardiography and magnetoencephalography, and the accuracy of medical measurements depends largely on the performance of the magnetometers. A double -pass configuration is used to obtain uniform polarization and constructed by adding a mirror to retro -reflect the pump light. The transmission model of the reflected light which takes the effect of forward light into account is proposed, and the improved polarization is experimentally verified. The essential operation parameters of the magnetometer are optimized. The theoretical framework is established outlining the relationship between pump power, probe frequency, and signal response, and the optimal values for these parameters are experimentally determined. With the appropriate selection of probe power and operating temperature, the double -pass configuration achieves a sensitivity of 5.81 fT/Hz 1/2 , a bandwidth of 110 Hz, and represents a 17% improvement in stability compared to the single -pass configuration. The optimized magnetometer exhibits reduced susceptibility to laser conditions and enhanced stability, attributed to the reflection -assisted polarization improvement and better uniformity. This configuration efficiently utilizes the pumping laser, and its miniaturization offers significant benefits for magnetoencephalography and other biomagnetic measurements.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Temperature compensation methods of spin-exchange relaxation-free co-magnetometer
    Wu, Jiaqi
    Liu, Feng
    Fan, Wenfeng
    Du, Pengcheng
    Quan, Wei
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (01)
  • [22] Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography
    李建军
    杜鹏程
    伏吉庆
    王旭桐
    周庆
    王如泉
    Chinese Physics B, 2019, (04) : 149 - 153
  • [23] A miniaturized spin-exchange relaxation-free atomic magnetometer based on uniform light field
    Li, Jiajie
    Fang, Xiujie
    Li, Renjie
    Chen, Baodong
    Zhai, Yueyang
    Liu, Ying
    CHINESE PHYSICS B, 2023, 32 (05)
  • [24] Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields
    Li, Lin
    Tang, Junjian
    Zhao, Binbin
    Cao, Li
    Zhou, Binquan
    Zhai, Yueyang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (50)
  • [25] A miniaturized spin-exchange relaxation-free atomic magnetometer based on uniform light field
    李佳洁
    房秀杰
    李任杰
    陈宝栋
    翟跃阳
    刘颖
    Chinese Physics B, 2023, 32 (05) : 435 - 440
  • [26] Reachability Analysis of The Atomic Spin Polarization for Spin-Exchange Relaxation-Free Atomic Magnetometers
    Wang, Ruigang
    Wang, Zhuo
    Ma, Chong
    Li, Shun
    Xu, Tiexiao
    Fang, Mengliang
    Liu, Zehua
    2022 4TH INTERNATIONAL CONFERENCE ON CONTROL AND ROBOTICS, ICCR, 2022, : 199 - 203
  • [27] In Situ Calibration of Coils Constant in a Spin-Exchange Relaxation-Free (SERF) Co-magnetometer
    Cao, Qian
    Liu, Ying
    Tang, Junjian
    Zhao, Tian
    Heng, Xing
    Zhai, Yueyang
    MEASUREMENT, 2023, 214
  • [28] Precise Determination of Magnetic Gradient Relaxation of Coupled Atomic Spin Ensemble in Spin-Exchange Relaxation-Free Co-Magnetometer
    Fang, Xiujie
    Wei, Kai
    Fan, Wenfeng
    Li, Siran
    Cao, Qian
    Quan, Wei
    Zhai, Yueyang
    Xiao, Zhisong
    PHOTONICS, 2023, 10 (04)
  • [29] A compact and closed-loop spin-exchange relaxation-free atomic magnetometer for wearable magnetoencephalography
    Guo, Qing-Qian
    Hu, Tao
    Feng, Xiao-Yu
    Zhang, Ming-Kang
    Chen, Chun-Qiao
    Zhang, Xin
    Yao, Ze-Kun
    Xu, Jia-Yu
    Wang, Qing
    Fu, Fang-Yue
    Zhang, Yin
    Chang, Yan
    Yang, Xiao-Dong
    CHINESE PHYSICS B, 2023, 32 (04)
  • [30] A compact and closed-loop spin-exchange relaxation-free atomic magnetometer for wearable magnetoencephalography
    郭清乾
    胡涛
    冯晓宇
    张明康
    陈春巧
    张欣
    姚泽坤
    徐佳玉
    王青
    付方跃
    张寅
    常严
    杨晓冬
    Chinese Physics B, 2023, 32 (04) : 327 - 332