A polarization-improved dual-beam spin-exchange relaxation-free magnetometer with reflection-assisted pumping

被引:2
|
作者
Huang, Binyue [1 ,7 ]
Liu, Ying [1 ,2 ,3 ,4 ,5 ]
Li, Renjie [1 ,4 ]
Li, Jiajie [1 ,4 ]
Tang, Junjian [1 ,4 ,8 ]
Zhai, Yueyang [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
[2] Beihang Univ, Inst Large scale Sci Facil, Beijing 100191, Peoples R China
[3] Beihang Univ, Ctr Zero Magnet Field Sci, Beijing 100191, Peoples R China
[4] Beihang Univ, Hangzhou Innovat Inst, Zhejiang Prov Key Lab Ultraweak Magnet Field Space, Hangzhou 310051, Peoples R China
[5] Natl Inst Extremely Weak Magnet Field Infrastruct, Hangzhou 310051, Peoples R China
[6] Hefei Natl Lab, Hefei 230088, Peoples R China
[7] Beihang Univ, Shen Yuan Honors Coll, Beijing 100191, Peoples R China
[8] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Reflective atomic magnetometer; Double-pass pumping; Optical polarization; Spin-exchange relaxation-free; High sensitivity; ATOMIC MAGNETOMETER;
D O I
10.1016/j.sna.2024.115523
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The highly sensitive SERF magnetometers hold exciting prospects for magnetocardiography and magnetoencephalography, and the accuracy of medical measurements depends largely on the performance of the magnetometers. A double -pass configuration is used to obtain uniform polarization and constructed by adding a mirror to retro -reflect the pump light. The transmission model of the reflected light which takes the effect of forward light into account is proposed, and the improved polarization is experimentally verified. The essential operation parameters of the magnetometer are optimized. The theoretical framework is established outlining the relationship between pump power, probe frequency, and signal response, and the optimal values for these parameters are experimentally determined. With the appropriate selection of probe power and operating temperature, the double -pass configuration achieves a sensitivity of 5.81 fT/Hz 1/2 , a bandwidth of 110 Hz, and represents a 17% improvement in stability compared to the single -pass configuration. The optimized magnetometer exhibits reduced susceptibility to laser conditions and enhanced stability, attributed to the reflection -assisted polarization improvement and better uniformity. This configuration efficiently utilizes the pumping laser, and its miniaturization offers significant benefits for magnetoencephalography and other biomagnetic measurements.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Optimal buffer gas pressure in dual-beam spin-exchange relaxation-free magnetometers
    Lu, Jixi
    Zhang, Shaowen
    Zhou, Ying
    Yan, Yeguang
    Lu, Fei
    Wang, Kun
    Zhai, Yueyang
    Ye, Mao
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 347
  • [2] Measurement of Relaxation Mechanism for the Spin-Exchange Relaxation-Free Magnetometer
    Peng, Jin
    Xu, An-Ning
    Yin, Yiran
    Liu, Bei
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 1333 - 1339
  • [3] In situ magnetic compensation for potassium spin-exchange relaxation-free magnetometer considering probe beam pumping effect
    Fang, Jiancheng
    Wang, Tao
    Quan, Wei
    Yuan, Heng
    Zhang, Hong
    Li, Yang
    Zou, Sheng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (06):
  • [4] Determination of Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometer Using Transient Response
    Zhao, Junpeng
    Ding, Ming
    Lu, Jixi
    Yang, Ke
    Ma, Danyue
    Yao, Han
    Han, Bangcheng
    Liu, Gang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (03) : 845 - 852
  • [5] Signal Space Separation for Spin-Exchange Relaxation-Free magnetometer
    Gao, Yang
    Shi, Zemin
    Ma, Xin
    He, Ning
    Tang, Xiaogang
    Wang, Defeng
    PROCEEDINGS OF THE 2021 IEEE INTERNATIONAL CONFERENCE ON FLEXIBLE AND PRINTABLE SENSORS AND SYSTEMS (FLEPS), 2021,
  • [6] Spin-exchange relaxation-free magnetic gradiometer with dual-beam and closed-loop Faraday modulation
    Fang, Jiancheng
    Wan, Shuangai
    Qin, Jie
    Zhang, Chen
    Quan, Wei
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2014, 31 (03) : 512 - 516
  • [7] Design of a photoelastic modulator in the spin-exchange relaxation-free magnetometer
    Wu, Ye
    Hu, Zhaohui
    Duan, Lihong
    OPTICAL MEASUREMENT TECHNOLOGY AND INSTRUMENTATION, 2016, 10155
  • [8] Measurement and Suppression of Transverse Optical Pumping in a Spin-Exchange Relaxation-Free Co-Magnetometer
    Wei, Yao
    Zhai, Yueyang
    Li, Renjie
    Liu, Sixun
    Fan, Wenfeng
    Quan, Wei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [9] Optimizations of spin-exchange relaxation-free magnetometer based on potassium and rubidium hybrid optical pumping
    Fang, Jiancheng
    Wang, Tao
    Zhang, Hong
    Li, Yang
    Zou, Sheng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (12):
  • [10] Measuring Spin Polarization of a Spin-Exchange Relaxation-Free Atomic Magnetometer at Extremely Large Optical Depths
    Ma, Yanning
    Lu, Jixi
    Yang, Ke
    Wang, Zixuan
    Wang, Yaoguo
    Sun, Bowen
    Zhai, Yueyang
    Han, Bangcheng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71