Static Mode Testing of S-20 Optical Streak Camera

被引:0
|
作者
Mangalmurti, Ankita [1 ]
Upadhyay, Jankee [2 ]
Kumar, Sudhir [2 ]
Arya, Rajesh [2 ]
Jain, Anjana [1 ]
Trivedi, Preeti [1 ]
机构
[1] Shri GS Inst Technol & Sci, Dept Elect & Telecommun, Indore, Madhya Pradesh, India
[2] Raja Ramanna Ctr Adv Technol, Laser Elect Support Div, Indore, Madhya Pradesh, India
关键词
CCD; Image intensifier tube; Micro channel plate; Ramp generator; Streak tube; VARIABLE AMPLITUDE;
D O I
10.1080/03772063.2024.2353348
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The spectral response of the S-20 streak camera ranges from 350 to 850 nanometers. The streak camera consists of a streak tube and an image intensifier tube followed by a CCD camera. The optical streak camera can be operated in three modes viz. static mode, gated mode, and dynamic mode. In static mode, various electrodes are checked by applying suitable DC voltages For this purpose, a high-voltage biasing network is developed. Gated mode operation is introduced to improve signal-to-noise ratio. So, the Micro Channel Plate (MCP) of the image intensifier tube will be activated with the gated signal.
引用
收藏
页码:7537 / 7545
页数:9
相关论文
共 50 条
  • [1] MULTIALKALI PHOTOCATHODE (S-20) OPTIMIZATION - USE IN STREAK CAMERA TUBES AND IMAGE INTENSIFIERS ASSOCIATED
    BEGHIN, M
    ESCHARD, G
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 281 - 286
  • [2] Absorption of optical power in an S-20 photocathode
    Harmer, SW
    Townsend, PD
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (13) : 1477 - 1483
  • [3] OPTICAL AND SPECTRAL PROPERTIES OF S-20 PHOTOCATHODES ON NESA SUBSTRATES
    MORRISON, CW
    APPLIED OPTICS, 1967, 6 (03): : 573 - &
  • [4] Theoretical and static experiment research on all optical solid state streak camera
    Liang Ling-Liang
    Tian Jin-Shou
    Wang Tao
    Li Fu-Li
    Gao Gui-Long
    Wang Jun-Feng
    Wang Chao
    Lu Yu
    Xu Xiang-Yan
    Cao Xi-Bin
    Wen Wen-Long
    Xin Li-Wei
    Liu Hu-Lin
    Wang Xing
    ACTA PHYSICA SINICA, 2014, 63 (06)
  • [5] Measurement of optical streak camera sensitivity
    Peng, Bodong
    Wang, Peiwei
    Li, Kuinian
    Yuan, Yuan
    Sheng, Liang
    Guangxue Xuebao/Acta Optica Sinica, 2015, 35 (08):
  • [6] All-Optical Streak Camera
    Heebner, John E.
    Sarantos, Chris H.
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 1262 - 1263
  • [7] Optical streak camera with gated photocathode
    Li J.
    Yang Z.
    Hu X.
    Zhang X.
    Wang F.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (12):
  • [8] Streak camera: a multidetector for diffuse optical tomography
    Zint, CV
    Uhring, W
    Torregrossa, M
    Cunin, B
    Poulet, P
    APPLIED OPTICS, 2003, 42 (16) : 3313 - 3320
  • [9] Compact optical technique for streak camera calibration
    Bell, P
    Griffith, R
    Hagans, K
    Lerche, R
    Allen, C
    Davies, T
    Janson, F
    Justin, R
    Marshall, B
    Sweningsen, O
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3930 - 3933
  • [10] ULTRAFAST STREAK CAMERA FOR OPTICAL PULSE MEASUREMENTS
    HOUGHTON, JW
    THOMAS, SW
    COLEMAN, LW
    ISA TRANSACTIONS, 1975, 14 (03) : 196 - 203