Compact optical technique for streak camera calibration

被引:3
|
作者
Bell, P
Griffith, R
Hagans, K
Lerche, R
Allen, C
Davies, T
Janson, F
Justin, R
Marshall, B
Sweningsen, O
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[2] Bechtel Nevada, Special Technol Lab, Santa Barbara, CA 93111 USA
[3] Bechtel Nevada, Livermore Operat, Livermore, CA 94551 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2004年 / 75卷 / 10期
关键词
D O I
10.1063/1.1789250
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To produce accurate data from optical streak cameras requires accurate temporal calibration sources. We have reproduced an older technology for generating optical timing marks that had been lost due to component availability. Many improvements have been made which allow the modern units to service a much larger need. Optical calibrators are now available that produce optical pulse trains of 780 nm wavelength light at frequencies ranging from 0.1 to 10 GHz, with individual pulse widths of approximately 25 ps full width half maximum. Future plans include the development of single units that produce multiple frequencies to cover a wide temporal range, and that are fully controllable via an RS232 interface. (C) 2004 American Institute of Physics.
引用
收藏
页码:3930 / 3933
页数:4
相关论文
共 50 条
  • [1] TECHNIQUE FOR STREAK CAMERA WRITING RATE CALIBRATION USING PULSED LASER
    CHRISTENSEN, AB
    ISBELL, WM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (05): : 559 - +
  • [2] OPTICAL FIBER DISPERSION MEASUREMENT TECHNIQUE USING A STREAK CAMERA
    MOCHIZUKI, K
    FUJISE, M
    KUWAZURU, M
    NUNOKAWA, M
    IWAMOTO, Y
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1987, 5 (01) : 119 - 124
  • [3] OPTICAL FIBER DISPERSION MEASUREMENT TECHNIQUE USING A STREAK CAMERA.
    Mochizuki, Kiyofumi
    Fujise, Masayuki
    Kuwazuru, Masakuni
    Nunokawa, Masakuni
    Iwamoto, Yoshinao
    Journal of Lightwave Technology, 1987, LT-5 (01) : 119 - 124
  • [4] CALIBRATION OF AN IMAGE-CONVERTER STREAK CAMERA
    AHRENS, TJ
    SPETZLER, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (02): : 354 - &
  • [5] Measurement of optical streak camera sensitivity
    Peng, Bodong
    Wang, Peiwei
    Li, Kuinian
    Yuan, Yuan
    Sheng, Liang
    Guangxue Xuebao/Acta Optica Sinica, 2015, 35 (08):
  • [6] All-Optical Streak Camera
    Heebner, John E.
    Sarantos, Chris H.
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 1262 - 1263
  • [7] Optical streak camera with gated photocathode
    Li J.
    Yang Z.
    Hu X.
    Zhang X.
    Wang F.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (12):
  • [8] TECHNIQUE FOR CAMERA CALIBRATION
    Noskovicova, Lucia
    Ravas, Rudolf
    ANNALS OF DAAAM FOR 2008 & PROCEEDINGS OF THE 19TH INTERNATIONAL DAAAM SYMPOSIUM, 2008, : 975 - 976
  • [9] Calibration of electron spectrometer resolution in attosecond streak camera
    Feng, Ximao
    Gilbertson, Steve
    Khan, Sabih D.
    Chini, Michael
    Wu, Yi
    Carnes, Kevin
    Chang, Zenghu
    OPTICS EXPRESS, 2010, 18 (02): : 1316 - 1322
  • [10] Streak camera: a multidetector for diffuse optical tomography
    Zint, CV
    Uhring, W
    Torregrossa, M
    Cunin, B
    Poulet, P
    APPLIED OPTICS, 2003, 42 (16) : 3313 - 3320