Static Mode Testing of S-20 Optical Streak Camera

被引:0
|
作者
Mangalmurti, Ankita [1 ]
Upadhyay, Jankee [2 ]
Kumar, Sudhir [2 ]
Arya, Rajesh [2 ]
Jain, Anjana [1 ]
Trivedi, Preeti [1 ]
机构
[1] Shri GS Inst Technol & Sci, Dept Elect & Telecommun, Indore, Madhya Pradesh, India
[2] Raja Ramanna Ctr Adv Technol, Laser Elect Support Div, Indore, Madhya Pradesh, India
关键词
CCD; Image intensifier tube; Micro channel plate; Ramp generator; Streak tube; VARIABLE AMPLITUDE;
D O I
10.1080/03772063.2024.2353348
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The spectral response of the S-20 streak camera ranges from 350 to 850 nanometers. The streak camera consists of a streak tube and an image intensifier tube followed by a CCD camera. The optical streak camera can be operated in three modes viz. static mode, gated mode, and dynamic mode. In static mode, various electrodes are checked by applying suitable DC voltages For this purpose, a high-voltage biasing network is developed. Gated mode operation is introduced to improve signal-to-noise ratio. So, the Micro Channel Plate (MCP) of the image intensifier tube will be activated with the gated signal.
引用
收藏
页码:7537 / 7545
页数:9
相关论文
共 50 条
  • [21] Optical and x-ray streak camera gain measurements
    Ghosh, S
    Boni, R
    Jaanimagi, PA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3956 - 3958
  • [22] Development of streak camera with anisotropic focusing electron optical system
    Tian, J.
    Ding, Y.
    Cao, X.
    Liu, S.
    Xu, X.
    Hu, X.
    Wen, W.
    Wang, J.
    Wang, C.
    Liu, H.
    Dong, G.
    Zhang, T.
    Lu, Y.
    Wang, X.
    Liu, J.
    2ND INTERNATIONAL SYMPOSIUM ON LASER INTERACTION WITH MATTER (LIMIS 2012), 2013, 8796
  • [23] Fluorescence measurement by a streak camera in a single-photon-counting mode
    Komura, Masayuki
    Itoh, Shigeru
    PHOTOSYNTHESIS RESEARCH, 2009, 101 (2-3) : 119 - 133
  • [24] Absolute calibration of the soft X-ray streak camera static characteristic
    Yi, RQ
    Zheng, ZJ
    Hu, X
    Cui, MQ
    Zhao, YD
    Zhu, PP
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2003, 27 (05): : 452 - 454
  • [25] OPTICAL FIBER DISPERSION MEASUREMENT TECHNIQUE USING A STREAK CAMERA
    MOCHIZUKI, K
    FUJISE, M
    KUWAZURU, M
    NUNOKAWA, M
    IWAMOTO, Y
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1987, 5 (01) : 119 - 124
  • [26] Fluorescence measurement by a streak camera in a single-photon-counting mode
    Masayuki Komura
    Shigeru Itoh
    Photosynthesis Research, 2009, 101 : 119 - 133
  • [27] DETECTION OF A NEW KIND OF CONDENSATIONS IN THE CENTER OF THE ORION NEBULA, BY MEANS OF S-20 PHOTO-CATHODES ASSOCIATED WITH A LALLEMAND ELECTRONIC CAMERA
    LAQUES, P
    VIDAL, JL
    ASTRONOMY & ASTROPHYSICS, 1979, 73 (1-2) : 97 - 106
  • [28] Solid state streak camera prototype performance testing and future upgrades
    Opachich, Y. P.
    MacNeil, L.
    Heinmiller, J. M.
    Alarie, A.
    Brienza-Larsen, G.
    Kimmel, M.
    Long, J.
    Looker, Q.
    Max, D.
    Patterson, R.
    Stahoviak, J. W.
    Waltman, T.
    Porter, J. L.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (05)
  • [29] Solid State Streak Camera Prototype Electronic Performance Testing and Characterization
    Opachich, Y. P.
    Looker, Q.
    MacNeil, L.
    Alarie, A.
    Kimmel, M. W.
    Long, J.
    Max, D.
    Stahoviak, J. W.
    Tran, V.
    Wolf, C.
    Waltman, T.
    Porter, J. L.
    TARGET DIAGNOSTICS PHYSICS AND ENGINEERING FOR INERTIAL CONFINEMENT FUSION VI, 2017, 10390
  • [30] High quantum efficiency S-20 photocathodes in photon counting detectors
    Orlov, D. A.
    DeFazio, J.
    Pinto, S. Duarte
    Glazenborg, R.
    Kernen, E.
    JOURNAL OF INSTRUMENTATION, 2016, 11