Investigation of the Optimal Operation Method of the Heat Recovery Ground Source Heat Pump System Installed in an Actual Building and Evaluation of Energy Saving Effect

被引:0
|
作者
Katsura, Takao [1 ]
Nakamura, Yasushi [2 ]
Ohara, Tomoya [3 ]
Kinouchi, Ken [4 ]
Nagano, Katsunori [1 ]
机构
[1] Hokkaido Univ, Fac Engn, Sapporo 0608628, Japan
[2] Nippon Steel Engn Co Ltd, 1-5-1 Osaki,Shinagawa Ku, Tokyo 1418604, Japan
[3] TEPCO Energy Partner Inc, 8-13-1 Ginza,Chuo Ku, Tokyo 1040061, Japan
[4] Japan Patent Off, 3-4-3 Kasumigaseki,Chiyoda Ku, Tokyo 1008915, Japan
关键词
ground source heat pump; heat recovery; simultaneously operation of cooling and hot water supply; simulation; long-term measurement; PERFORMANCE ANALYSIS; MANAGEMENT; SIMULATION;
D O I
10.3390/en17143558
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a heat recovery ground source heat pump (HR-GSHP) system, in which the primary pipes of the GSHP for air conditioning and the GSHP for hot water are connected to ground heat exchangers (GHEs) and each GSHP is operated simultaneously or within a short period of time, was installed in a dormitory building on a trial basis. Then, the optimal operation method to minimize the energy consumption of the system was investigated. The operating period of the GSHP for HW was changed and simulations were conducted to determine the operating period with the lowest energy consumption, which was 8 months from April to November. Furthermore, the HR-GSHP system was operated for 8 years from 2012 to 2019, and actual measurements were carried out to verify the system performance and the energy saving effect in optimal operation. In actual operation, it was confirmed that the minimum temperature was about 10 degrees C or higher even when the GSHP for HW was operated year-round. Therefore, the GSHP for HW was operated year-round after the third year of operation. It was confirmed that the operation of the GSHP for HW in summer, especially in August and September when the cooling load is large, can improve the system's efficiency by the effect of recovering cooling exhaust heat. In the eighth year of operation, when the GSHP for HW was operated most during the summer season, the system was able to reduce power consumption for air conditioning and hot water supply by approximately 17%.
引用
收藏
页数:27
相关论文
共 50 条
  • [41] Energy saving analysis on the recovery fresh air heat pump units of a public building
    Chen, Aoxue
    Liu, Hailong
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2955 - +
  • [42] The Use of Ground Source Heat Pump to Achieve a Net Zero Energy Building
    D'Agostino, Diana
    Mele, Luigi
    Minichiello, Francesco
    Renno, Carlo
    ENERGIES, 2020, 13 (13)
  • [43] Cooling performance of a vertical ground-coupled heat pump system installed in a school building
    Hwang, Yujin
    Lee, Jae-Keun
    Jeong, Young-Man
    Koo, Kyung-Min
    Lee, Dong-Hyuk
    Kim, In-Kyu
    Jin, Sim-Won
    Kim, Soo H.
    RENEWABLE ENERGY, 2009, 34 (03) : 578 - 582
  • [44] Operation optimization of the coaxial deep borehole heat exchanger coupled with ground source heat pump for building heating
    Wang, Yaran
    Wang, Yeming
    You, Shijun
    Zheng, Xuejing
    Wei, Shen
    APPLIED THERMAL ENGINEERING, 2022, 213
  • [45] Experimental investigation on the operation performance of a direct expansion ground source heat pump system for space heating
    Wang, Huajun
    Zhao, Qian
    Wu, Juntao
    Yang, Bin
    Chen, Zhihao
    ENERGY AND BUILDINGS, 2013, 61 : 349 - 355
  • [46] Efficiency Analysis Of Ground Source Heat Pump In Energy-Saving Building Based on Multi Target & Multi Constraint
    Bai Bing
    Wang Chongen
    PROCEEDINGS OF THE 2015 INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE, 2015, 7 : 169 - 173
  • [47] Experimental investigation and control optimization of a ground source heat pump system
    Xia, Lei
    Ma, Zhenjun
    McLauchlan, Craig
    Wang, Shugang
    APPLIED THERMAL ENGINEERING, 2017, 127 : 70 - 80
  • [48] The Alternate Operation Characteristics of a Solar-ground Source Heat Pump System
    Yang, Weibo
    Shi, Mingheng
    Chen, Zhenqian
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1816 - 1824
  • [49] Study on Operation Optimization Strategy of Ground Source Heat Pump Heating System
    Chen, Cheng
    Chen, Xingying
    Yu, Kun
    Gan, Lei
    2018 2ND IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2018,
  • [50] Optimizing the Operation of a Hybrid Solar Assisted Ground Source Heat Pump System
    Weeratunge, Hansani
    Dunstall, Simon
    de Hoog, Julian
    Narsilio, Guillermo
    Halgamuge, Saman
    2018 IEEE 9TH INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION FOR SUSTAINABILITY (ICIAFS' 2018), 2018,