Effectiveness of the Attachment Design and Thickness of Clear Aligners during Orthodontic Anterior Retraction: Finite Element Analysis

被引:7
|
作者
Alhasyimi, Ananto Ali [1 ]
Ayub, Aulia
Farmasyanti, Cendrawasih Andusyana [1 ]
机构
[1] Univ Gadjah Mada, Fac Dent, Dept Orthodont, Yogyakarta 55281, Indonesia
关键词
attachment; clear aligner; force; orthodontic; retraction; thickness;
D O I
10.1055/s-0043-1761452
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective Clear aligner treatment (CAT) provides orthodontic patients with a comfortable treatment alternative; however, this device has limited capacity to facilitate tooth movements. Although composite attachment has been proposed to facilitate tooth displacement, some of its aspects, such as aligner thickness, can influence CAT's precision. This work aimed to compare the stress distribution patterns produced by clear aligners with different thicknesses and composite attachment shapes during anterior retraction. Materials and Methods Maxillary models consisting of clear aligners, maxillary teeth, and various attachments to the upper central incisor's labial surface were generated. Three models were built to mimic the retraction of the upper central incisors. Each had a distinct attachment design (rectangular attachment, ellipsoid attachment, and pyramidal attachment) and various aligner thicknesses (0.75, 0.85, 0.95, 1.05, and 1.15 mm). Upper central incisor retraction was accomplished using clear aligners. Finite element analysis was used to examine the built models. Stress distribution pattern was examined. Results The greater the thickness of the aligner, the higher the stress experienced by the teeth. The 0.75 mm-thick aligner induces the lightest stress with a minimum of 0.0037623 MPa and a maximum of 0.32859 MPa. Meanwhile, the 1.5 mm-thick aligner has the highest stress with a minimum of 0.004679 MPa and a maximum of 0.43858 MPa. The force distribution on rectangular attachments appears evenly distributed. The maximum pressure force on rectangular attachments has a minimum of 0.38828 MPa, which is smaller than the maximum on ellipsoid and pyramidal attachments at 0.40933 and 0.45099 MPa, respectively. Conclusion The best aligner thickness is 0.75 to 0.85 mm for anterior retraction. An aligner with 0.95 mm thickness can still be used when a remarkable amount of tooth movement force is needed; however, this exception is only applicable to a limited number of clear aligner trays. The ellipsoid attachment is the best type of attachment because the resulting force is substantial and evenly distributed.
引用
收藏
页码:174 / 181
页数:8
相关论文
共 50 条
  • [31] Computer-aided finite element model for biomechanical analysis of orthodontic aligners
    Elshazly, Tarek M.
    Bourauel, Christoph
    Aldesoki, Mostafa
    Ghoneima, Ahmed
    Abuzayda, Moosa
    Talaat, Wael
    Talaat, Sameh
    Keilig, Ludger
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (01) : 115 - 124
  • [32] Computer-aided finite element model for biomechanical analysis of orthodontic aligners
    Tarek M. Elshazly
    Christoph Bourauel
    Mostafa Aldesoki
    Ahmed Ghoneima
    Moosa Abuzayda
    Wael Talaat
    Sameh Talaat
    Ludger Keilig
    Clinical Oral Investigations, 2023, 27 : 115 - 124
  • [33] Biomechanical analysis of clear aligners for mandibular anterior teeth intrusion and its clinical application in the design of new aligner attachment
    Xiao, Shengzhao
    Cheng, Caiqi
    Li, Haochen
    Li, Lin
    Shen, Canao
    Feng, Qiping
    Zhao, Yan
    Duan, Yufeng
    Xia, Lunguo
    Chu, Fengting
    Fang, Bing
    PROGRESS IN ORTHODONTICS, 2025, 26 (01):
  • [34] Effects of different patterns of movement for correcting a deep curve of Spee with clear aligners on the anterior teeth: a finite element analysis
    Zhu, Lin
    Liu, Lin
    Wang, Wei
    Deng, Wen Wen
    BMC ORAL HEALTH, 2024, 24 (01)
  • [35] Effects of different patterns of movement for correcting a deep curve of Spee with clear aligners on the anterior teeth: a finite element analysis
    Lin Zhu
    Lin Liu
    Wei Wang
    Wen Wen Deng
    BMC Oral Health, 24
  • [36] Biomechanical effects of corticotomy facilitated orthodontic anterior retraction: a 3-dimensional finite element analysis
    Liu, Yang
    Wu, Yan
    Yang, Chongshi
    Song, Jinlin
    Fan, Yubo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (07) : 295 - 302
  • [37] A retrospective study of alveolar bone remodelling after anterior retraction in orthodontic tooth extraction cases with clear aligners and fixed appliances
    Guo, Ziyu
    Zhang, Ruijie
    Guo, Changgang
    Li, Xin
    Jin, Zuolin
    Liu, Qian
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2024, 27 (02) : 220 - 227
  • [38] Effects of Attachment Orientation and Designed Vertical Movement on Molar Distalisation With Clear Aligners: A Biomechanical Finite Element Study
    Li, Jialun
    Yang, Yi
    He, Xian
    Lai, Wenli
    Long, Hu
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2025, 28 (02) : 296 - 303
  • [39] Periodontal health during orthodontic treatment with clear aligners and fixed appliances A meta-analysis
    Jiang, Qian
    Li, Jialing
    Mei, Li
    Du, Jing
    Levrini, Luca
    Abbate, Gian Marco
    Li, Huang
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2018, 149 (08): : 712 - +
  • [40] Biomechanical effects of different mandibular movements and torque compensations during mandibular advancement with clear aligners: a finite element analysis
    Wang, Ya
    Daraqel, Baraa
    Wang, Ying
    Yang, Dan
    Dong, Yihan
    Hu, Yun
    Zheng, Leilei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12