Effectiveness of the Attachment Design and Thickness of Clear Aligners during Orthodontic Anterior Retraction: Finite Element Analysis

被引:7
|
作者
Alhasyimi, Ananto Ali [1 ]
Ayub, Aulia
Farmasyanti, Cendrawasih Andusyana [1 ]
机构
[1] Univ Gadjah Mada, Fac Dent, Dept Orthodont, Yogyakarta 55281, Indonesia
关键词
attachment; clear aligner; force; orthodontic; retraction; thickness;
D O I
10.1055/s-0043-1761452
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective Clear aligner treatment (CAT) provides orthodontic patients with a comfortable treatment alternative; however, this device has limited capacity to facilitate tooth movements. Although composite attachment has been proposed to facilitate tooth displacement, some of its aspects, such as aligner thickness, can influence CAT's precision. This work aimed to compare the stress distribution patterns produced by clear aligners with different thicknesses and composite attachment shapes during anterior retraction. Materials and Methods Maxillary models consisting of clear aligners, maxillary teeth, and various attachments to the upper central incisor's labial surface were generated. Three models were built to mimic the retraction of the upper central incisors. Each had a distinct attachment design (rectangular attachment, ellipsoid attachment, and pyramidal attachment) and various aligner thicknesses (0.75, 0.85, 0.95, 1.05, and 1.15 mm). Upper central incisor retraction was accomplished using clear aligners. Finite element analysis was used to examine the built models. Stress distribution pattern was examined. Results The greater the thickness of the aligner, the higher the stress experienced by the teeth. The 0.75 mm-thick aligner induces the lightest stress with a minimum of 0.0037623 MPa and a maximum of 0.32859 MPa. Meanwhile, the 1.5 mm-thick aligner has the highest stress with a minimum of 0.004679 MPa and a maximum of 0.43858 MPa. The force distribution on rectangular attachments appears evenly distributed. The maximum pressure force on rectangular attachments has a minimum of 0.38828 MPa, which is smaller than the maximum on ellipsoid and pyramidal attachments at 0.40933 and 0.45099 MPa, respectively. Conclusion The best aligner thickness is 0.75 to 0.85 mm for anterior retraction. An aligner with 0.95 mm thickness can still be used when a remarkable amount of tooth movement force is needed; however, this exception is only applicable to a limited number of clear aligner trays. The ellipsoid attachment is the best type of attachment because the resulting force is substantial and evenly distributed.
引用
收藏
页码:174 / 181
页数:8
相关论文
共 50 条
  • [21] The effect of space arrangement between anterior teeth on their retraction with clear aligners in first premolar extraction treatment: a finite element study
    Cao, Yuan
    Wang, Zhi-Wei
    Chen, Da
    Liu, Lu
    Li, Deng-Xin
    Li, Ni
    Ying, Si-Qi
    Liu, Xin
    Jin, Fang
    PROGRESS IN ORTHODONTICS, 2023, 24 (01)
  • [22] Effects of overtreatment with different attachment positions on maxillary anchorage enhancement with clear aligners: a finite element analysis study
    Shiyu Wang
    Yangyang Huang
    Dian Fan
    Hao Liu
    Changyong Yuan
    Li Yang
    Penglai Wang
    BMC Oral Health, 23
  • [23] Effects of overtreatment with different attachment positions on maxillary anchorage enhancement with clear aligners: a finite element analysis study
    Wang, Shiyu
    Huang, Yangyang
    Fan, Dian
    Liu, Hao
    Yuan, Changyong
    Yang, Li
    Wang, Penglai
    BMC ORAL HEALTH, 2023, 23 (01)
  • [24] Evaluation of the effect of different attachment configurations on molar teeth in maxillary expansion with clear aligners - a finite element analysis
    Karsli, Nurver
    Ocak, Irmak
    Akyildiz, Muge
    Gogen, Hakan
    Dalci, Oyku
    BMC ORAL HEALTH, 2024, 24 (01):
  • [25] A finite element analysis of the effects of semipontic design on tooth movement during mesialization of the mandibular second molar with clear aligners
    Akan, Burcu Ece Koru
    Kircelli, Beyza Hanciog
    Bozkurt, Aylin Pasagolu
    Gogen, Hakan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2024, 166 (05) : 490 - 502
  • [26] Dynamic biomechanical changes of clear aligners during extraction space closure: Finite element analysis
    Wang, Yi-gan
    Zhu, Guan-yin
    Liu, Jun-qi
    Wang, Yi-fan
    Zhao, Zhi-he
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2024, 165 (03) : 272 - 284.e3
  • [27] Incisors Extrusion with Clear Aligners Technique: A Finite Element Analysis Study
    Rossini, Gabriele
    Modica, Stefano
    Parrini, Simone
    Deregibus, Andrea
    Castroflorio, Tommaso
    APPLIED SCIENCES-BASEL, 2021, 11 (03): : 1 - 7
  • [28] Biomechanical Efficacy and Effectiveness of Orthodontic Treatment with Transparent Aligners in Mild Crowding Dentition-A Finite Element Analysis
    Seo, Jeong-Hee
    Kim, Min-Seok
    Lee, Jeong-Hyeon
    Eghan-Acquah, Emmanuel
    Jeong, Yong-Hoon
    Hong, Mi-Hee
    Kim, Bongju
    Lee, Sung-Jae
    MATERIALS, 2022, 15 (09)
  • [29] EFFECTIVENESS OF CLEAR ORTHODONTIC ALIGNERS IN CORRECTING MALOCCLUSIONS: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Baneshi, Maryam
    O'malley, Lucy
    El-angbawi, Ahmed
    Thiruvenkatachari, Badri
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2025, 25 (01)
  • [30] Effect of attachment configuration and trim line design on the force system of orthodontic aligners: A finite element study on the upper central incisor
    Elshazly, Tarek M.
    Bourauel, Christoph
    Aldesoki, Mostafa
    Salvatori, Damiano
    Alhotan, Abdulaziz
    Keilig, Ludger
    Ghoneima, Ahmed
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2024, 27 : 131 - 140