Fully resolved high-precision measurement of 36S for sulfur reference materials

被引:1
|
作者
Sun, Jiayang [1 ]
Farquhar, James [1 ,2 ]
机构
[1] Univ Maryland, Dept Geol, 8051 Regents Dr, College Pk, MD 20742 USA
[2] Univ Maryland, Earth Syst Sci Interdisciplinary Ctr, College Pk, MD USA
基金
美国国家航空航天局;
关键词
S-36/S-32; isobaric interference; panorama high resolution IRMS; sulfur isotope calibration; ISOTOPE REFERENCE MATERIALS; CARBON-DIOXIDE; IAEA SULFUR; FRACTIONATIONS; METEORITES; DELTA-S-34; METROLOGY; ABUNDANCE; RATIOS; PHASE;
D O I
10.1002/rcm.9768
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale : Advances in sulfur isotope measurement techniques have led to increased analytical precision. However, accurate measurement of S-36 remains a challenge. This difficulty arises primarily from unresolved isobaric interferences of (SF5+)-S-36 at m/z = 131 u, (WF42+)-W-186 and (C3F5+)-C-12, which lead to scale compression. Theoretically, unresolved interference with 2% relative intensity could cause 1 parts per thousand underestimation in a sample with real delta S-36 = +60 parts per thousand. Methods : Our study develops an interference-free four-sulfur isotope measurement method by using the high-resolution mass spectrometer Panorama. The mass resolving power of Panorama allows the distinction of (WF42+)-W-186 and (C3F5+)-C-12 from (SF5+)-S-36. Results : The (WF42+)-W-186 relative intensity was initially 9.4% that of (SF5+)-S-36 but reduced to 1.5% through tuning, while (C3F5+)-C-12 relative intensity dropped from 74% to 40% after flushing with air. Three IAEA standards were analyzed with both Panorama and MAT 253. We obtained Delta S-36(IAEA-S-2) = 1.238 +/- 0.040 parts per thousand and Delta S-36(IAEA-S-3) = -0.882 +/- 0.030 parts per thousand, relative to IAEA-S-1, from Panorama, and Delta S-36(IAEA-S-2) = 0.18 +/- 0.02 parts per thousand and Delta S-36(IAEA-S-3) = 0.11 +/- 0.14 parts per thousand from MAT 253, while delta S-34 values from the two instruments are consistent. Conclusion : The measurement discrepancies on S-36 between Panorama and MAT 253 highlight the impact of scale compression due to unresolved isobaric interferences. Resolving this problem is crucial for accurate S-36 analysis. We recommend replacing the filament material with rhenium, tuning the filament voltage, and avoiding carbon in instruments to eliminate or mitigate interferences. We propose future systematic efforts to calibrate the delta S-33, delta S-34, and delta S-36 of IAEA-S-1, IAEA-S-2, and IAEA-S-3 and advise bracketing all three reference materials in the measurement sequences, to enable calibration.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] High-precision, High-temperature-Reference Pyrometer
    不详
    CHEMIE INGENIEUR TECHNIK, 2020, 92 (11) : 1647 - 1650
  • [22] High-precision grating period measurement
    Photia, Thanarwut
    Temnuch, Wipawee
    Srisuphaphon, Sorakrai
    Tanasanchai, Nuttanan
    Anukool, Waranont
    Wongrach, Kunaree
    Manit, Pachara
    Chiangga, Surasak
    Deachapunya, Sarayut
    APPLIED OPTICS, 2019, 58 (02) : 270 - 273
  • [23] MEASUREMENT OF SMALL HIGH-PRECISION ANGLES
    CHEKANOV, VE
    MEASUREMENT TECHNIQUES USSR, 1992, 35 (09): : 1113 - 1114
  • [24] A High-precision Binocular Measurement System
    Fu Yue-gang
    Jin Fan-hao
    COMPUTING, CONTROL AND INDUSTRIAL ENGINEERING IV, 2013, 823 : 402 - 405
  • [25] Compact trimming design of a high-precision reference
    任国栋
    赵世芳
    蒲忠胜
    魏智强
    Journal of Semiconductors, 2014, 35 (04) : 138 - 141
  • [26] Compact trimming design of a high-precision reference
    任国栋
    赵世芳
    蒲忠胜
    魏智强
    Journal of Semiconductors, 2014, (04) : 138 - 141
  • [27] Compact trimming design of a high-precision reference
    Ren Guodong
    Zhao Shifang
    Pu Zhongshen
    Wei Zhiqiang
    JOURNAL OF SEMICONDUCTORS, 2014, 35 (04)
  • [28] DEVICE FOR HIGH-PRECISION TIME-RESOLVED SPECTROSCOPY
    BARDOCZ, A
    SPECTROCHIMICA ACTA, 1960, 16 (10): : 1173 - +
  • [29] High-precision Determination of Gold Mass Fractions in Geological Reference Materials by Internal Standardisation
    Cheng, Huai
    Wang, Zaicong
    Chen, Kang
    Zong, Keqing
    Zou, Zongqi
    He, Tao
    Hu, Zhaochu
    Fischer-Goedde, Mario
    Liu, Yanhong
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2019, 43 (04) : 663 - 680
  • [30] HIGH-PRECISION TIME-RESOLVED CCD PHOTOMETRY
    KJELDSEN, H
    FRANDSEN, S
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1992, 104 (676) : 413 - 434