Fully resolved high-precision measurement of 36S for sulfur reference materials

被引:1
|
作者
Sun, Jiayang [1 ]
Farquhar, James [1 ,2 ]
机构
[1] Univ Maryland, Dept Geol, 8051 Regents Dr, College Pk, MD 20742 USA
[2] Univ Maryland, Earth Syst Sci Interdisciplinary Ctr, College Pk, MD USA
基金
美国国家航空航天局;
关键词
S-36/S-32; isobaric interference; panorama high resolution IRMS; sulfur isotope calibration; ISOTOPE REFERENCE MATERIALS; CARBON-DIOXIDE; IAEA SULFUR; FRACTIONATIONS; METEORITES; DELTA-S-34; METROLOGY; ABUNDANCE; RATIOS; PHASE;
D O I
10.1002/rcm.9768
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale : Advances in sulfur isotope measurement techniques have led to increased analytical precision. However, accurate measurement of S-36 remains a challenge. This difficulty arises primarily from unresolved isobaric interferences of (SF5+)-S-36 at m/z = 131 u, (WF42+)-W-186 and (C3F5+)-C-12, which lead to scale compression. Theoretically, unresolved interference with 2% relative intensity could cause 1 parts per thousand underestimation in a sample with real delta S-36 = +60 parts per thousand. Methods : Our study develops an interference-free four-sulfur isotope measurement method by using the high-resolution mass spectrometer Panorama. The mass resolving power of Panorama allows the distinction of (WF42+)-W-186 and (C3F5+)-C-12 from (SF5+)-S-36. Results : The (WF42+)-W-186 relative intensity was initially 9.4% that of (SF5+)-S-36 but reduced to 1.5% through tuning, while (C3F5+)-C-12 relative intensity dropped from 74% to 40% after flushing with air. Three IAEA standards were analyzed with both Panorama and MAT 253. We obtained Delta S-36(IAEA-S-2) = 1.238 +/- 0.040 parts per thousand and Delta S-36(IAEA-S-3) = -0.882 +/- 0.030 parts per thousand, relative to IAEA-S-1, from Panorama, and Delta S-36(IAEA-S-2) = 0.18 +/- 0.02 parts per thousand and Delta S-36(IAEA-S-3) = 0.11 +/- 0.14 parts per thousand from MAT 253, while delta S-34 values from the two instruments are consistent. Conclusion : The measurement discrepancies on S-36 between Panorama and MAT 253 highlight the impact of scale compression due to unresolved isobaric interferences. Resolving this problem is crucial for accurate S-36 analysis. We recommend replacing the filament material with rhenium, tuning the filament voltage, and avoiding carbon in instruments to eliminate or mitigate interferences. We propose future systematic efforts to calibrate the delta S-33, delta S-34, and delta S-36 of IAEA-S-1, IAEA-S-2, and IAEA-S-3 and advise bracketing all three reference materials in the measurement sequences, to enable calibration.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] High-precision EPMA measurement of trace elements in ilmenite and reference material development
    Jia, Li-Hui
    Mao, Qian
    Tian, Heng-Ci
    Li, Li-Xing
    Qi, Liang
    Wu, Shi-Tou
    Yuan, Jiang-Yan
    Huang, Liang-Liang
    Chen, Yi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2351 - 2361
  • [12] High-precision EPMA measurement of trace elements in ilmenite and reference material development
    Jia, Li-Hui
    Mao, Qian
    Tian, Heng-Ci
    Li, Li-Xing
    Qi, Liang
    Wu, Shi-Tou
    Yuan, Jiang-Yan
    Huang, Liang-Liang
    Chen, Yi
    Journal of Analytical Atomic Spectrometry, 2022, 37 (11): : 2351 - 2361
  • [13] Multiple Sulfur Isotope Determination by SIMS: Evaluation of Reference Sulfides for Δ33S with Observations and a Case Study on the Determination of Δ36S
    Whitehouse, Martin J.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2013, 37 (01) : 19 - 33
  • [14] An improved femtosecond laser-ablation fluorination method for measurements of sulfur isotopic anomalies ( increment 33S and increment 36S) in sulfides with high precision
    Velivetskaya, Tatiana A.
    Ignatiev, Alexander V.
    Yakovenko, Victoria V.
    Vysotskiy, Sergey V.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (22) : 1722 - 1729
  • [15] High-precision testing of brittle materials
    ASM International, United States
    不详
    Advanced Materials and Processes, 1997, 151 (04): : 39 - 40
  • [16] High-precision testing of brittle materials
    Khersonsky, A
    ADVANCED MATERIALS & PROCESSES, 1997, 151 (04): : 39 - 40
  • [17] HIGH-PRECISION SPECTROPHOTOMETRY OF MATERIALS AND COATINGS
    NIKITIN, VA
    VOROBEV, VG
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1988, 55 (12): : 746 - 753
  • [18] HIGH-PRECISION MEASUREMENT OF SMALL BALLS
    CHETWYND, DG
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (10): : 1179 - 1187
  • [19] High-precision measurement of the swelling of microspheres
    Wironen, J
    Shen, C
    Yan, J
    Batich, C
    JOURNAL OF APPLIED POLYMER SCIENCE, 1996, 59 (05) : 825 - 830
  • [20] High-precision nanoscale length measurement
    Sheglov D.V.
    Kosolobov S.S.
    Fedina L.I.
    Rodyakina E.E.
    Gutakovskii A.K.
    Sitnikov S.V.
    Kozhukhov A.S.
    Zagarskikh S.A.
    Kopytov V.V.
    Evgrafov V.I.
    Shuvalov G.V.
    Matveichuk V.F.
    Latyshev A.V.
    Nanotechnologies in Russia, 2013, 8 (7-8): : 518 - 531