Accuracy and Precision of Haptic Robotic-Guided Implant Surgery in a Large Consecutive Series

被引:5
|
作者
Neugarten, M. [1 ]
机构
[1] Weill Cornell Med Ctr, New York Ctr Orthognath & Maxillofacial Surg, New York, NY 10065 USA
关键词
robotics; dental implant; haptics; accuracy; SURGICAL GUIDES; PLACEMENT; TEMPLATES;
D O I
10.11607/jomi.10468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To determine the accuracy of dental implant placement using haptic robotic guidance in a large clinical series. Materials andMethods: In a prospective single-arm clinical study, 108 patients received 273 individual endosteal implants. A virtual preoperative restorative and surgical plan was created from a CBCT scan and matched to the surgical workspace on the day of surgery via either a tooth-based or bone-based fiducial splint. Intraoperatively, the surgeon manipulated a handpiece attached to a haptic robotic guidance arm. A variety of drills and implants were used. Both the osteotomy and the implant placement were guided by 3D haptic constraints according to the virtual plan. Postoperative CBCT scans permitted the calculation of the actual implant placement deviations compared to the plan for accuracy. Precision was calculated by comparing SDs from published literature. Results: The implants were evenly distributed by arch, with 47% placed in the maxilla and 53% in the mandible. The mean +/- SD signed depth deviation was 0.14 +/- 0.87 mm proud. The global angular deviation averaged 1.42 +/- 1.53 degrees, with 95% confidence limits of 1.24 and 1.60 degrees. The crown of the actual placed implant showed an average deviation from the plan of 1.10 +/- 0.69 mm and the apex of the placed implant showed a deviation of 1.12 +/- 0.69 mm. Haptic robotic guidance showed greater precision than freehand, static computerguided, and dynamic computer-guided implant placement. Conclusions: This large clinical series of 273 implants shows a high accuracy of implant placement compared to the published accuracy for angular deviations for any technology, as weil as demonstrating statistically greater precision. Long-term clinical studies are necessary to establish the true effect of increased accuracy on clinical outcomes. Using haptic robotic guidance provides accurate implant placement while allowing additional benefits compared to computer-guided surgery, namely full visualization of the surgical field and the ability to change the plan intraoperatively. Inti Oral Maxillofac Implants 2024;39:99-106. doi: 10.11607/jomi.10468
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [1] Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement
    Sven Rainer Kantelhardt
    Ramon Martinez
    Stefan Baerwinkel
    Ralf Burger
    Alf Giese
    Veit Rohde
    European Spine Journal, 2011, 20 : 860 - 868
  • [2] Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement
    Kantelhardt, Sven Rainer
    Martinez, Ramon
    Baerwinkel, Stefan
    Burger, Ralf
    Giese, Alf
    Rohde, Veit
    EUROPEAN SPINE JOURNAL, 2011, 20 (06) : 860 - 868
  • [3] Robotic-guided placement of cervical pedicle screws: feasibility and accuracy
    Stanley Kisinde
    Xiaobang Hu
    Shea Hesselbacher
    Alexander M. Satin
    Isador H. Lieberman
    European Spine Journal, 2022, 31 : 693 - 701
  • [4] Robotic-guided placement of cervical pedicle screws: feasibility and accuracy
    Kisinde, Stanley
    Hu, Xiaobang
    Hesselbacher, Shea
    Satin, Alexander M.
    Lieberman, Isador H.
    EUROPEAN SPINE JOURNAL, 2022, 31 (03) : 693 - 701
  • [5] Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches
    Bolding, Scotty L.
    Reebye, Uday N.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 639 - 647
  • [6] Accuracy and Deviation Analysis of Static and Robotic Guided Implant Surgery: A Case Study
    Mozer, Paul S.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) : E86 - E90
  • [7] Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series
    Yang, Shuo
    Chen, Jiahao
    Li, An
    Deng, Ke
    Li, Ping
    Xu, Shulan
    JOURNAL OF DENTISTRY, 2023, 132
  • [8] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1279 - 1288
  • [9] Accuracy of guided dental implant surgery using a fully digital workflow: A case series
    Massuda, Carlos Kiyoshi Moreira
    de Carvalho, Marcia Rosa
    de Moraes, Joao Baptista
    Pallos, Debora
    Kim, Yeon Jung
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 973 - 980
  • [10] Influence of Metal Guide Sleeves on the Accuracy and Precision of Dental Implant Placement Using Guided Implant Surgery: An In Vitro Study
    Adams, Coleman R.
    Ammoun, Rami
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 62 - 70