Accuracy and Precision of Haptic Robotic-Guided Implant Surgery in a Large Consecutive Series

被引:5
|
作者
Neugarten, M. [1 ]
机构
[1] Weill Cornell Med Ctr, New York Ctr Orthognath & Maxillofacial Surg, New York, NY 10065 USA
关键词
robotics; dental implant; haptics; accuracy; SURGICAL GUIDES; PLACEMENT; TEMPLATES;
D O I
10.11607/jomi.10468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To determine the accuracy of dental implant placement using haptic robotic guidance in a large clinical series. Materials andMethods: In a prospective single-arm clinical study, 108 patients received 273 individual endosteal implants. A virtual preoperative restorative and surgical plan was created from a CBCT scan and matched to the surgical workspace on the day of surgery via either a tooth-based or bone-based fiducial splint. Intraoperatively, the surgeon manipulated a handpiece attached to a haptic robotic guidance arm. A variety of drills and implants were used. Both the osteotomy and the implant placement were guided by 3D haptic constraints according to the virtual plan. Postoperative CBCT scans permitted the calculation of the actual implant placement deviations compared to the plan for accuracy. Precision was calculated by comparing SDs from published literature. Results: The implants were evenly distributed by arch, with 47% placed in the maxilla and 53% in the mandible. The mean +/- SD signed depth deviation was 0.14 +/- 0.87 mm proud. The global angular deviation averaged 1.42 +/- 1.53 degrees, with 95% confidence limits of 1.24 and 1.60 degrees. The crown of the actual placed implant showed an average deviation from the plan of 1.10 +/- 0.69 mm and the apex of the placed implant showed a deviation of 1.12 +/- 0.69 mm. Haptic robotic guidance showed greater precision than freehand, static computerguided, and dynamic computer-guided implant placement. Conclusions: This large clinical series of 273 implants shows a high accuracy of implant placement compared to the published accuracy for angular deviations for any technology, as weil as demonstrating statistically greater precision. Long-term clinical studies are necessary to establish the true effect of increased accuracy on clinical outcomes. Using haptic robotic guidance provides accurate implant placement while allowing additional benefits compared to computer-guided surgery, namely full visualization of the surgical field and the ability to change the plan intraoperatively. Inti Oral Maxillofac Implants 2024;39:99-106. doi: 10.11607/jomi.10468
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [21] Analysis of implant precision in guided surgery: comparison of two methods
    Viscardi, Daniele
    Carini, Fabio
    Saggese, Vito
    Carini, Fabrizio
    MINERVA DENTAL AND ORAL SCIENCE, 2024, 73 (01) : 27 - 36
  • [22] Accuracy of full guided vs. half-guided implant surgery
    Kuehl, S.
    Zuercher, S.
    Mahid, T.
    Mueller-Gerbl, M.
    Filippi, A.
    Cattin, P.
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (07) : 763 - 769
  • [23] Accuracy of autonomous robotic surgery for dental implant placement in fully edentulous patients: A retrospective case series study
    Li, Ping
    Chen, Jiahao
    Li, An
    Luo, Ke
    Xu, Shulan
    Yang, Shuo
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (12) : 1428 - 1437
  • [24] Accuracy of guided implant surgery: an experimental set-up
    Ruoppoli, Andrea
    Beltrame, Cesare
    Tonoli, Giorgio
    Amaroli, Andrea
    De Angelis, Nicola
    MINERVA STOMATOLOGICA, 2019, 68 (02): : 61 - 66
  • [25] Robotic-guided sacro-pelvic fixation using S2 alar-iliac screws: feasibility and accuracy
    Hu, Xiaobang
    Lieberman, Isador H.
    EUROPEAN SPINE JOURNAL, 2017, 26 (03) : 720 - 725
  • [26] Optimum Design of 6R Passive Haptic Robotic Arm for Implant Surgery
    Yilmaz, Serter
    Konukseven, E. Ilhan
    Gurocak, Hakan
    HAPTICS: GENERATING AND PERCEIVING TANGIBLE SENSATIONS, PT I, PROCEEDINGS, 2010, 6191 : 105 - +
  • [27] In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer-assisted implant surgery
    He, Jin
    Zhang, Qinmeng
    Wang, Xueting
    Fu, Mengdie
    Zhang, Hui
    Song, Luyao
    Pu, Rui
    Jiang, Zhiwei
    Yang, Guoli
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 385 - 401
  • [28] A Vision-Guided Robotic System for Safe Dental Implant Surgery
    Pisla, Daria
    Bulbucan, Vasile
    Hedesiu, Mihaela
    Vaida, Calin
    Zima, Ionut
    Mocan, Rares
    Tucan, Paul
    Dinu, Cristian
    Pisla, Doina
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (21)
  • [29] Robotic-guided sacro-pelvic fixation using S2 alar-iliac screws: feasibility and accuracy
    Xiaobang Hu
    Isador H. Lieberman
    European Spine Journal, 2017, 26 : 720 - 725
  • [30] Accuracy and operation procedure of robotic computer-aided implant surgery
    Liu, Yitian
    Zheng, Qingqing
    Xu, Zonghe
    Lin, Yanjun
    Zhang, Sihui
    Huang, Wenxiu
    Chen, Jiang
    Wu, Dong
    SCIENTIFIC REPORTS, 2025, 15 (01):