Assessment of ocular injuries using high-resolution 3D ultrasound

被引:0
|
作者
Minhaz, Ahmed Tahseen [1 ]
Orge, Faruk H. [2 ,3 ]
Wilson, David L. [1 ,4 ]
Bayat, Mahdi [5 ]
机构
[1] Case Western Reserve Univ, Biomed Engn, Cleveland, OH USA
[2] Case Western Reserve Univ, Sch Med, Ophthalmol, Cleveland, OH 44106 USA
[3] Univ Hosp Cleveland, Pediat Ophthalmol & Adult Strabismus, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Sch Med, Radiol, Cleveland, OH USA
[5] Case Western Reserve Univ, Elect Comp & Syst Engn, Cleveland, OH USA
关键词
ultrasound; 3D; ophthalmology; injury; foreign body;
D O I
10.1117/12.3006195
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We developed a novel high resolution 3D ultrasound B-scan (3D-UBS) imaging system that provides automated 3D acquisition and easily interpretable, interactive 3D visualization, including en-face and oblique views of the whole eye. Early and accurate diagnosis of ocular trauma and other associated injuries is essential for future prevention of complications. Conventional 2D ultrasound is limited in its use due to lack of trained ultrasonographer at point-of-care, difficulty in finding the optimal imaging plane and lack of anatomical context for easy interpretation. 2D hand-held ultrasound is also limited in case of perforated globes. Computed tomography (CT) is expensive and cannot be utilized if perforating intraocular foreign bodies (IOFBs) are small, non-metallic, or organic in nature. This study aimed to address the unmet clinical need for advanced 3D visualization of IOFBs and ocular injuries with 3D-UBS. We imaged porcine eye models for IOFBs. 3D-UBS enabled easily-obtained, informative images of ocular injuries, without an expert as required in conventional 2D ultrasound. En face and oblique views provided by multiplanar reformatting allows selection of optimal planes after acquisition. Size and shape of the IOFBs can be detected more accurately with 3D-UBS. 3D-UBS also provides information on location of IOFBs with respect to other important ocular structures. 3D-UBS shows 2.4 times contrast improvement compared to CT in wooden IOFB visualization. Our study demonstrated that novel 3D-UBS can be used for assessing ocular injuries (i.e., identifying the location, size, and shape of IOFBs) which can guide the treatment process.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Towards Video Guidance for Ultrasound, Using a Prior High-Resolution 3D Surface Map of the External Anatomy
    Wang, Jihang
    Shivaprabhu, Vikas
    Galeotti, John
    Horvath, Samantha
    Gorantla, Vijay
    Stetten, George
    [J]. AUGMENTED ENVIRONMENTS FOR COMPUTER-ASSISTED INTERVENTIONS (AE-CAI 2014), 2014, 8678 : 51 - +
  • [22] A method for 3D measurement with high resolution using ultrasound spherical waves
    Matani, A
    Nambu, M
    Kondo, A
    Oshiro, O
    Chihara, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (5B): : 3255 - 3259
  • [23] Method for 3D measurement with high resolution using ultrasound spherical waves
    Matani, Ayumu
    Nambu, Masayuki
    Kondo, Atushi
    Oshiro, Osamu
    Chihara, Kunihiro
    [J]. Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1997, 36 (5 B): : 3255 - 3259
  • [24] STUDY OF A HIGH-RESOLUTION 3D PET SCANNER
    ZHANG, SP
    BRUYNDONCKX, P
    GOLDBERG, MB
    TAVERNIER, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 607 - 612
  • [25] High-Resolution 3D Radial bSSFP with IDEAL
    Moran, Catherine J.
    Brodsky, Ethan K.
    Bancroft, Leah Henze
    Reeder, Scott B.
    Yu, Huanzhou
    Kijowski, Richard
    Engel, Dorothee
    Block, Walter F.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 95 - 104
  • [26] CSpace® High-Resolution Volumetric 3D Display
    Refai, Hakki H.
    Melnik, George
    Willner, Mark
    [J]. THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2013, 2013, 8738
  • [27] On the road to high-resolution 3D molecular imaging
    Delcorte, Arnaud
    [J]. APPLIED SURFACE SCIENCE, 2008, 255 (04) : 954 - 958
  • [28] High-resolution 3D digital models of artworks
    Fontana, R
    Gambino, MC
    Greco, M
    Pampaloni, E
    Pezzati, L
    Scopigno, R
    [J]. OPTICAL METROLOGY FOR ARTS AND MULTIMEDIA, 2003, 5146 : 34 - 43
  • [29] Local Readjustment for High-Resolution 3D Reconstruction
    Zhu, Siyu
    Fang, Tian
    Xiao, Jianxiong
    Quan, Long
    [J]. 2014 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2014, : 3938 - 3945
  • [30] 3D high-resolution anorectal manometry in patients with perianal fistulas: comparison with 3D-anal ultrasound
    Richelle J. F. Felt-Bersma
    Maarten S. Vlietstra
    Paul F. Vollebregt
    Ingrid J. M. Han-Geurts
    Vera Rempe-Sorm
    Grietje J. H. Vander Mijnsbrugge
    Charlotte B. H. Molenaar
    [J]. BMC Gastroenterology, 18