Dynamic X-ray Flux Modulation of Inverse-Geometry CT

被引:0
|
作者
Shen, Liuxing [1 ]
Windsor, Haydon [1 ]
Zhou, Shuang [2 ]
Jiang, Hao [1 ]
Zhang, Tiezhi [1 ,2 ]
机构
[1] Tetraimaging LLC, Maryland Hts, MO 63043 USA
[2] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
Distributed x-ray source; Inverse-geometry CT; CT dose reduction;
D O I
10.1117/12.3006916
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A novel inverse-geometry CT based on multi-pixel thermionic emission x-ray (MPTEX) sources is under development. Inverse-geometry CT is capable of modulating x-ray flux based on region of interest (ROI) location and thus minimizing x-ray exposure to the patients. The variations of emission currents of the MPTEX source at each projection angle are predetermined based on ROI position and realized by varying filament heating powers. To power and control filament electron emissions, a 50-channel prototype MPTEX control unit was developed based on GaN switching power technology. The filament heating powers of electron sources are controlled individually by a microprocessor while electron emission is turned on and off by switching the bias voltages during inverse-geometry CT scans. The emission current was measured as a function of filament heating voltage. The result shows that magnitude of emission current can be controlled dynamically by varying filament heating voltages. Compared with pulse width modulation, this approach can effectively prolong the lifetime of the filaments by minimizing their working temperature. A simulation of electron emission current sinogram was conducted as well. This work is supoorted by NIH grant R42EB026401.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] What is inverse-geometry CT?
    Schmidt, Taly Gilat
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (03) : 145 - 148
  • [2] Multisource inverse-geometry CT. Part II. X-ray source design and prototype
    Neculaes, V. Bogdan
    Caiafa, Antonio
    Cao, Yang
    De Man, Bruno
    Edic, Peter M.
    Frutschy, Kristopher
    Gunturi, Satish
    Inzinna, Lou
    Reynolds, Joseph
    Vermilyea, Mark
    Wagner, David
    Zhang, Xi
    Zou, Yun
    Pelc, Norbert J.
    Lounsberry, Brian
    MEDICAL PHYSICS, 2016, 43 (08) : 4617 - 4627
  • [3] Inverse-Geometry CT with a Rotating C-Arm: Implementation On the Scanning Beam Digital X-Ray System
    Slagowski, J.
    Speidel, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3033 - 3033
  • [4] A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array
    Baek, Jongduk
    De Man, Bruno
    Uribe, Jorge
    Longtin, Randy
    Harrison, Daniel
    Reynolds, Joseph
    Neculaes, Bogdan
    Frutschy, Kristopher
    Inzinna, Louis
    Caiafa, Antonio
    Senzig, Robert
    Pelc, Norbert J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05): : 1189 - 1202
  • [5] Preliminary study on optimization of the stationary inverse-geometry digital tomosynthesis: X-ray source array
    Kim, Burnyoung
    Eom, Jisoo
    Kim, Wonhyung
    Lee, Seungwan
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [6] Noise simulations for an inverse-geometry volumetric CT system
    Schmidt, TG
    Fahrig, R
    Pelc, NJ
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 420 - 427
  • [7] Sparse-view Image Reconstruction in Inverse-geometry CT (IGCT) for Fast, Low-dose, Volumetric Dental X-ray Imaging
    Hong, D. K.
    Cho, H. S.
    Oh, J. E.
    Je, U. K.
    Lee, M. S.
    Kim, H. J.
    Lee, S. H.
    Park, Y. O.
    Choi, S. I.
    Koo, Y. S.
    Cho, H. M.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (12) : 2084 - 2090
  • [8] Sparse-view image reconstruction in inverse-geometry CT (IGCT) for fast, low-dose, volumetric dental X-ray imaging
    D. K. Hong
    H. S. Cho
    J. E. Oh
    U. K. Je
    M. S. Lee
    H. J. Kim
    S. H. Lee
    Y. O. Park
    S. I. Choi
    Y. S. Koo
    H. M. Cho
    Journal of the Korean Physical Society, 2012, 61 : 2084 - 2090
  • [9] Multisource Inverse-Geometry CT Prototype System Integration
    Uribe, Jorge
    Reynolds, Joseph L.
    Inzinna, Louis P.
    Longtin, Randy
    Harrison, Daniel D.
    De Man, Bruno
    Neculaes, Bogdan
    Caiafa, Antonio
    Waters, William
    Frutschy, Kristopher J.
    Senzig, Robert
    Baek, Jongduk
    Pelc, Norbert
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2578 - 2581
  • [10] Simulation study of a novel small animal FLASH irradiator (SAFI) with integrated inverse-geometry CT based on circularly distributed kV X-ray sources
    Yuewen Tan
    Shuang Zhou
    Jonathan Haefner
    Qinghao Chen
    Thomas R. Mazur
    Arash Darafsheh
    Tiezhi Zhang
    Scientific Reports, 13