Dynamic X-ray Flux Modulation of Inverse-Geometry CT

被引:0
|
作者
Shen, Liuxing [1 ]
Windsor, Haydon [1 ]
Zhou, Shuang [2 ]
Jiang, Hao [1 ]
Zhang, Tiezhi [1 ,2 ]
机构
[1] Tetraimaging LLC, Maryland Hts, MO 63043 USA
[2] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
Distributed x-ray source; Inverse-geometry CT; CT dose reduction;
D O I
10.1117/12.3006916
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A novel inverse-geometry CT based on multi-pixel thermionic emission x-ray (MPTEX) sources is under development. Inverse-geometry CT is capable of modulating x-ray flux based on region of interest (ROI) location and thus minimizing x-ray exposure to the patients. The variations of emission currents of the MPTEX source at each projection angle are predetermined based on ROI position and realized by varying filament heating powers. To power and control filament electron emissions, a 50-channel prototype MPTEX control unit was developed based on GaN switching power technology. The filament heating powers of electron sources are controlled individually by a microprocessor while electron emission is turned on and off by switching the bias voltages during inverse-geometry CT scans. The emission current was measured as a function of filament heating voltage. The result shows that magnitude of emission current can be controlled dynamically by varying filament heating voltages. Compared with pulse width modulation, this approach can effectively prolong the lifetime of the filaments by minimizing their working temperature. A simulation of electron emission current sinogram was conducted as well. This work is supoorted by NIH grant R42EB026401.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Inverse-geometry volumetric CT system with multiple detector arrays for wide field-of-view imaging
    Mazin, Samuel R.
    Star-Lack, Josh
    Bennett, N. Robert
    Pelc, Norbert J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2133 - 2142
  • [42] Scatter Correction Method by Temporal Primary Modulation in X-Ray CT
    Schoerner, Karsten
    Goldammer, Matthias
    Stierstorfer, Karl
    Stephan, Juergen
    Boeni, Peter
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (06) : 3278 - 3285
  • [43] X-RAY TUBE CURRENT MODULATION AND PATIENT DOSES IN CHEST CT
    He, Wenjun
    Huda, Walter
    Magill, Dennise
    Tavrides, Emily
    Yao, Hai
    RADIATION PROTECTION DOSIMETRY, 2011, 143 (01) : 81 - 87
  • [44] An X-Ray Fluence Modulation Apparatus for Cone-Beam CT
    Ghazi, P.
    Youssefian, S.
    Ghazi, T.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [45] Calibration-free device sizing using an inverse geometry x-ray system
    Tomkowiak, Michael T.
    Speidel, Michael A.
    Raval, Amish N.
    Van Lysel, Michael S.
    MEDICAL PHYSICS, 2011, 38 (01) : 283 - 293
  • [46] Inverse geometry for grating-based x-ray phase-contrast imaging
    Donath, Tilman
    Chabior, Michael
    Pfeiffer, Franz
    Bunk, Oliver
    Reznikova, Elena
    Mohr, Juergen
    Hempel, Eckhard
    Popescu, Stefan
    Hoheisel, Martin
    Schuster, Manfred
    Baumann, Joachim
    David, Christian
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (05)
  • [47] High precision calculation of the excitation flux for x-ray fluorescence spectroscopy with cylindrical geometry
    Gunen, A.
    Akkutay, C.
    Arikan, P.
    Applied Spectroscopy Reviews, 1998, 33 (1-2):
  • [48] A high precision calculation of the excitation flux for x-ray fluorescence spectroscopy with cylindrical geometry
    Gunen, A
    Akkutay, C
    Arikan, P
    APPLIED SPECTROSCOPY REVIEWS, 1998, 33 (1-2) : 151 - 165
  • [49] X-ray diffraction with novel geometry
    Prokopiou, Danae
    Rogers, Keith
    Evans, Paul
    Godber, Simon
    Shackel, James
    Dicken, Anthony
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 735 : 341 - 348
  • [50] Reverse geometry X-ray imaging
    Malglaive, F.
    Albert, R. D.
    INSIGHT, 2009, 51 (02) : 66 - 68