Determination of muscle shape deformations of the tibialis anterior during dynamic contractions using 3D ultrasound

被引:2
|
作者
Sahrmann, Annika S. [1 ,2 ]
Vosse, Lukas [2 ,3 ]
Siebert, Tobias [2 ,3 ]
Handsfield, Geoffrey G. [4 ]
Roehrle, Oliver [1 ,2 ]
机构
[1] Univ Stuttgart, Inst Modelling & Simulat Biomech Syst, Stuttgart, Germany
[2] Univ Stuttgart, Stuttgart Ctr Simulat Sci, Stuttgart, Germany
[3] Univ Stuttgart, Inst Sport & Movement Sci, Stuttgart, Germany
[4] Univ Auckland, Auckland Bioengn Inst, Auckland, New Zealand
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
关键词
3D ultrasound; image processing; dynamic movement; muscle deformation; contraction; CROSS-SECTIONAL AREA; GASTROCNEMIUS; ANGLE; ARCHITECTURE; PRESSURE; STRENGTH; GEARING; LENGTH; VOLUME;
D O I
10.3389/fbioe.2024.1388907
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose In this paper, we introduce a novel method for determining 3D deformations of the human tibialis anterior (TA) muscle during dynamic movements using 3D ultrasound.Materials and Methods An existing automated 3D ultrasound system is used for data acquisition, which consists of three moveable axes, along which the probe can move. While the subjects perform continuous plantar- and dorsiflexion movements in two different controlled velocities, the ultrasound probe sweeps cyclically from the ankle to the knee along the anterior shin. The ankle joint angle can be determined using reflective motion capture markers. Since we considered the movement direction of the foot, i.e., active or passive TA, four conditions occur: slow active, slow passive, fast active, fast passive. By employing an algorithm which defines ankle joint angle intervals, i.e., intervals of range of motion (ROM), 3D images of the volumes during movement can be reconstructed.Results We found constant muscle volumes between different muscle lengths, i.e., ROM intervals. The results show an increase in mean cross-sectional area (CSA) for TA muscle shortening. Furthermore, a shift in maximum CSA towards the proximal side of the muscle could be observed for muscle shortening. We found significantly different maximum CSA values between the fast active and all other conditions, which might be caused by higher muscle activation due to the faster velocity.Conclusion In summary, we present a method for determining muscle volume deformation during dynamic contraction using ultrasound, which will enable future empirical studies and 3D computational models of skeletal muscles.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] 3D Muscle Deformation Mapping at Submaximal Isometric Contractions: Applications to Aging Muscle
    Malis, Vadim
    Sinha, Usha
    Sinha, Shantanu
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [32] Nonlinear projection: Using deformations in 3D viewing
    Yang, YG
    Chen, JX
    Kim, W
    Kee, C
    COMPUTING IN SCIENCE & ENGINEERING, 2003, 5 (02) : 54 - 59
  • [33] A Channel for 3D Environmental Shape in Anterior Inferotemporal Cortex
    Vaziri, Siavash
    Carlson, Eric T.
    Wang, Zhihong
    Connor, Charles E.
    NEURON, 2014, 84 (01) : 55 - 62
  • [34] 3D registration by using an alternative 3D shape representation
    Torre-Ferrero, C.
    Robla, S.
    Sarabia, E. G.
    Llata, J. R.
    PROCEEDINGS OF THE 7TH WSEAS INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, COMPUTATIONAL GEOMETRY AND ARTIFICIAL VISION (ISCGAV'-07), 2007, : 97 - +
  • [35] Dynamic 3D Facial Expression Recognition Using Robust Shape Features
    Maalej, Ahmed
    Tabia, Hedi
    Benhabiles, Halim
    IMAGE ANALYSIS, SCIA 2013: 18TH SCANDINAVIAN CONFERENCE, 2013, 7944 : 309 - 318
  • [36] 3D ultrasound strain imaging of the puborectal muscle
    Das, S.
    Hansen, H.
    Hendriks, C.
    van den Noort, F.
    Manzini, C.
    van der Vaart, C.
    de Korte, C.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2020, 31 (SUPPL 1) : S198 - S199
  • [37] Clinical 3D Imaging of the Anterior Segment With Ultrasound Biomicroscopy
    Helms, Richard W.
    Minhaz, Ahmed Tahseen
    Wilson, David L.
    Orge, Faruk H.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (03):
  • [38] 3D ULTRASOUND STRAIN IMAGING OF PUBORECTALIS MUSCLE
    Das, Shreya
    Hansen, Hendrik H. G.
    Hendriks, Gijs A. G. M.
    van den Noort, Frieda
    Manzini, Claudia
    van der Vaart, C. Huub
    de Korte, Chris L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (03): : 569 - 581
  • [39] Quantitative pulsatility measurements using 3D dynamic ultrasound localization microscopy
    Bourquin, Chloe
    Poree, Jonathan
    Rauby, Brice
    Perrot, Vincent
    Ghigo, Nin
    Belgharbi, Hatim
    Belanger, Samuel
    Ramos-Palacios, Gerardo
    Cortes, Nelson
    Ladret, Hugo
    Ikan, Lamyae
    Casanova, Christian
    Lesage, Frederic
    Provost, Jean
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04):
  • [40] Minimizing Deformations during HP MJF 3D Printing
    Raz, Karel
    Chval, Zdenek
    Thomann, Sacha
    MATERIALS, 2023, 16 (23)