Determination of muscle shape deformations of the tibialis anterior during dynamic contractions using 3D ultrasound

被引:2
|
作者
Sahrmann, Annika S. [1 ,2 ]
Vosse, Lukas [2 ,3 ]
Siebert, Tobias [2 ,3 ]
Handsfield, Geoffrey G. [4 ]
Roehrle, Oliver [1 ,2 ]
机构
[1] Univ Stuttgart, Inst Modelling & Simulat Biomech Syst, Stuttgart, Germany
[2] Univ Stuttgart, Stuttgart Ctr Simulat Sci, Stuttgart, Germany
[3] Univ Stuttgart, Inst Sport & Movement Sci, Stuttgart, Germany
[4] Univ Auckland, Auckland Bioengn Inst, Auckland, New Zealand
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
关键词
3D ultrasound; image processing; dynamic movement; muscle deformation; contraction; CROSS-SECTIONAL AREA; GASTROCNEMIUS; ANGLE; ARCHITECTURE; PRESSURE; STRENGTH; GEARING; LENGTH; VOLUME;
D O I
10.3389/fbioe.2024.1388907
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose In this paper, we introduce a novel method for determining 3D deformations of the human tibialis anterior (TA) muscle during dynamic movements using 3D ultrasound.Materials and Methods An existing automated 3D ultrasound system is used for data acquisition, which consists of three moveable axes, along which the probe can move. While the subjects perform continuous plantar- and dorsiflexion movements in two different controlled velocities, the ultrasound probe sweeps cyclically from the ankle to the knee along the anterior shin. The ankle joint angle can be determined using reflective motion capture markers. Since we considered the movement direction of the foot, i.e., active or passive TA, four conditions occur: slow active, slow passive, fast active, fast passive. By employing an algorithm which defines ankle joint angle intervals, i.e., intervals of range of motion (ROM), 3D images of the volumes during movement can be reconstructed.Results We found constant muscle volumes between different muscle lengths, i.e., ROM intervals. The results show an increase in mean cross-sectional area (CSA) for TA muscle shortening. Furthermore, a shift in maximum CSA towards the proximal side of the muscle could be observed for muscle shortening. We found significantly different maximum CSA values between the fast active and all other conditions, which might be caused by higher muscle activation due to the faster velocity.Conclusion In summary, we present a method for determining muscle volume deformation during dynamic contraction using ultrasound, which will enable future empirical studies and 3D computational models of skeletal muscles.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Stable dynamic 3D shape models
    Domheim, L
    Tönnies, KD
    Dornheim, J
    2005 International Conference on Image Processing (ICIP), Vols 1-5, 2005, : 3384 - 3387
  • [22] Puborectalis muscle function assessed by dynamic 3D ultrasound imaging and vaginal pressures
    Guaderrama, N
    Liu, JM
    Nager, CW
    Pretorius, DH
    Sheean, G
    Mittal, RK
    GASTROENTEROLOGY, 2005, 128 (04) : A266 - A266
  • [23] ShapeTalk: A Language Dataset and Framework for 3D Shape Edits and Deformations
    Achlioptas, Panos
    Huang, Ian
    Sung, Minhyuk
    Tulyakov, Sergey
    Guibas, Leonidas
    2023 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2023, : 12685 - 12694
  • [24] 3D freeform design: Interactive shape deformations by the use of CyberGlove
    Sato, M
    Savchenko, V
    Ohbuchi, R
    2004 INTERNATIONAL CONFERENCE ON CYBERWORLDS, PROCEEDINGS, 2004, : 147 - 154
  • [25] FEEDBACK STABILIZATION OF A 3D FLUID FLOW BY SHAPE DEFORMATIONS OF AN OBSTACLE
    Raymond, Jean-Pierre
    Vanninathan, Muthusamy
    ESAIM-CONTROL OPTIMISATION AND CALCULUS OF VARIATIONS, 2021, 27 (27)
  • [26] 3D Catheter Shape Determination for Endovascular Navigation Using a Two-Step Particle Filter and Ultrasound Scanning
    Chen, Fang
    Liu, Jia
    Liao, Hongen
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (03) : 685 - 695
  • [27] Investigating the functions of human tibialis anterior during walking using a novel "muscle avatar′ technique
    Huck, T. G.
    Maharaj, J.
    Nishikawa, K. C.
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2023, 62 : S149 - S149
  • [28] High dynamic range 3D shape determination based on automatic exposure selection
    Rao, Li
    Da, Feipeng
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2018, 50 : 217 - 226
  • [29] The effects of skeletal muscle size on the tissue energy distribution and work output of 3D muscle during cyclic contractions
    Ross, S. A.
    Dominguez, S.
    Nigam, N.
    Wakeling, J. M.
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2021, 61 : E761 - E762
  • [30] Measurement of Tendon Strain During Muscle Twitch Contractions Using Ultrasound Elastography
    Farron, Joe
    Varghese, Tomy
    Thelen, Darryl G.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (01) : 27 - 35