Comparison of admittance and cardiac magnetic resonance generated pressure-volume loops in a porcine model

被引:0
|
作者
Andersen, Stine [1 ,2 ]
Laursen, Pernille Holmberg [1 ,2 ]
Wood, Gregory John [1 ,2 ]
Lyhne, Mads Dam [2 ,4 ]
Madsen, Tobias Lynge [1 ,3 ]
Hansen, Esben Sovso Szocska [3 ]
Johansen, Peter [5 ]
Kim, Won Yong [1 ,2 ]
Andersen, Mads Jonsson [1 ,2 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[3] Aarhus Univ, MR Res Ctr, Dept Clin Med, Aarhus, Denmark
[4] Aarhus Univ Hosp, Dept Anesthesiol & Intens Care, Aarhus, Denmark
[5] Aarhus Univ, Dept Elect & Comp Engn, Aarhus, Denmark
关键词
pressure-volume loops; cardiac magnetic resonance imaging; admittance; cardiac function; end-systolic elastance; RIGHT-VENTRICULAR DYSFUNCTION; SINGLE-BEAT ESTIMATION; IMAGING ANALYSIS; VALIDATION;
D O I
10.1088/1361-6579/ad4a03
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Pressure-volume loop analysis, traditionally performed by invasive pressure and volume measurements, is the optimal method for assessing ventricular function, while cardiac magnetic resonance (CMR) imaging is the gold standard for ventricular volume estimation. The aim of this study was to investigate the agreement between the assessment of end-systolic elastance (Ees) assessed with combined CMR and simultaneous pressure catheter measurements compared with admittance catheters in a porcine model. Approach. Seven healthy pigs underwent admittance-based pressure-volume loop evaluation followed by a second assessment with CMR during simultaneous pressure measurements. Main results. Admittance overestimated end-diastolic volume for both the left ventricle (LV) and the right ventricle (RV) compared with CMR. Further, there was an underestimation of RV end-systolic volume with admittance. For the RV, however, Ees was systematically higher when assessed with CMR plus simultaneous pressure measurements compared with admittance whereas there was no systematic difference in Ees but large differences between admittance and CMR-based methods for the LV. Significance. LV and RV Ees can be obtained from both admittance and CMR based techniques. There were discrepancies in volume estimates between admittance and CMR based methods, especially for the RV. RV Ees was higher when estimated by CMR with simultaneous pressure measurements compared with admittance.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Impact of Loading and Myocardial Mechanical Properties on Natural Shear Waves Comparison to Pressure-Volume Loops
    Bezy, Stephanie
    Duchenne, Jurgen
    Orlowska, Marta
    Caenen, Annette
    Amoni, Matthew
    Ingelaere, Sebastian
    Wouters, Laurine
    McCutcheon, Keir
    Minten, Lennert
    Puvrez, Alexis
    D'hooge, Jan
    Voigt, Jens-Uwe
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (12) : 2023 - 2034
  • [42] Cardiac pressure-volume loops during acute ischemia in the mouse.: A micro conductance catheter study
    Westermann, D
    Steendijk, P
    Schultheiss, HP
    Tschöpe, C
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2002, 29 (08) : A81 - A81
  • [43] PRESSURE-VOLUME RELATIONSHIP OF A MODEL ALVEOLUS
    NOZAKI, M
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1970, 101 (03): : 271 - 279
  • [44] A LOGARITHMIC MODEL OF THE PRESSURE-VOLUME CURVE
    EIDELMAN, D
    KIM, WD
    GHEZZO, H
    COSIO, MG
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A390 - A390
  • [45] Non-invasive pressure-volume loops from cardiovascular magnetic resonance predict cardiovascular mortality in heart failure with reduced ejection fraction
    Arvidsson, P. M.
    Berg, J.
    Jablonowski, R.
    Carlsson, M.
    Arheden, H.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [46] LEFT VENTRICULAR PRESSURE-VOLUME LOOPS IN MAN WITH VALVULAR HEART DISEASE
    DODGE, HT
    SANDLER, H
    HAY, RE
    CIRCULATION, 1961, 24 (04) : 920 - &
  • [47] Functional comparison of anaesthetic agents during myocardial ischaemia-reperfusion using pressure-volume loops
    Andrews, D. T.
    Royse, A. G.
    Royse, C. F.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (05) : 654 - 664
  • [48] Refining the gold standard: Volume calibration methods for right ventricular pressure-volume loops
    Houston, Brian A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2025, 44 (03): : 336 - 338
  • [49] Use of Pressure-Volume Loops for Physiological Assessment of Adult Laryngotracheal Stenosis
    Nouraei, S. Mahmoud
    Patel, Anil
    Virk, Jag S.
    Butler, Colin R.
    Sandhu, Guri S.
    Nouraei, S. A. Reza
    LARYNGOSCOPE, 2013, 123 (11): : 2735 - 2741
  • [50] Validation of conductance catheter system for quantification of murine pressure-volume loops
    Yang, B
    Larson, DF
    Beischel, J
    Kelley, R
    Shi, J
    Watson, RR
    JOURNAL OF INVESTIGATIVE SURGERY, 2001, 14 (06) : 341 - 355