Comparison of admittance and cardiac magnetic resonance generated pressure-volume loops in a porcine model

被引:0
|
作者
Andersen, Stine [1 ,2 ]
Laursen, Pernille Holmberg [1 ,2 ]
Wood, Gregory John [1 ,2 ]
Lyhne, Mads Dam [2 ,4 ]
Madsen, Tobias Lynge [1 ,3 ]
Hansen, Esben Sovso Szocska [3 ]
Johansen, Peter [5 ]
Kim, Won Yong [1 ,2 ]
Andersen, Mads Jonsson [1 ,2 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[3] Aarhus Univ, MR Res Ctr, Dept Clin Med, Aarhus, Denmark
[4] Aarhus Univ Hosp, Dept Anesthesiol & Intens Care, Aarhus, Denmark
[5] Aarhus Univ, Dept Elect & Comp Engn, Aarhus, Denmark
关键词
pressure-volume loops; cardiac magnetic resonance imaging; admittance; cardiac function; end-systolic elastance; RIGHT-VENTRICULAR DYSFUNCTION; SINGLE-BEAT ESTIMATION; IMAGING ANALYSIS; VALIDATION;
D O I
10.1088/1361-6579/ad4a03
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Pressure-volume loop analysis, traditionally performed by invasive pressure and volume measurements, is the optimal method for assessing ventricular function, while cardiac magnetic resonance (CMR) imaging is the gold standard for ventricular volume estimation. The aim of this study was to investigate the agreement between the assessment of end-systolic elastance (Ees) assessed with combined CMR and simultaneous pressure catheter measurements compared with admittance catheters in a porcine model. Approach. Seven healthy pigs underwent admittance-based pressure-volume loop evaluation followed by a second assessment with CMR during simultaneous pressure measurements. Main results. Admittance overestimated end-diastolic volume for both the left ventricle (LV) and the right ventricle (RV) compared with CMR. Further, there was an underestimation of RV end-systolic volume with admittance. For the RV, however, Ees was systematically higher when assessed with CMR plus simultaneous pressure measurements compared with admittance whereas there was no systematic difference in Ees but large differences between admittance and CMR-based methods for the LV. Significance. LV and RV Ees can be obtained from both admittance and CMR based techniques. There were discrepancies in volume estimates between admittance and CMR based methods, especially for the RV. RV Ees was higher when estimated by CMR with simultaneous pressure measurements compared with admittance.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Cardiovascular magnetic resonance imaging-guided right heart catheterizations for cardiac pressure-volume loop analyses
    van de Veerdonk, Marielle C.
    Hopman, Luuk H. G. A.
    Frenaij, Irene M.
    Luijk, Raschel D.
    Wessels, Jeroen N.
    Kamp, Otto
    Nelissen, Jules L.
    Allaart, Cornelis P.
    Gotte, Marco J. W.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (06) : 735 - 738
  • [32] Biventricular Assessment of Cardiac Function and Pressure-Volume Loops by Closed-Chest Catheterization in Mice
    Potus, Francois
    Martin, Ashley Y.
    Snetsinger, Brooke
    Archer, Stephen L.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (160): : 1 - 20
  • [33] A COMPARISON OF PRESSURE-VOLUME MODELS IN HYDROCEPHALUS
    SIMON, RH
    LEHMAN, RAW
    OCONNOR, SJ
    NEUROSURGERY, 1984, 15 (05) : 694 - 699
  • [34] A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats
    Raghavan, Karthik
    Feldman, Marc D.
    Porterfield, John E.
    Larson, Erik R.
    Jenkins, J. Travis
    Escobedo, Daniel
    Pearce, John A.
    Valvano, Jonathan W.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (06) : 701 - 715
  • [35] Comprehensive cardiac phenotyping in large animals: comparison of pressure-volume analysis and cardiac magnetic resonance imaging in pig post-myocardial infarction systolic heart failure
    Raake, Philip W. J.
    Barthelmes, Jens
    Krautz, Birgit
    Buss, Sebastian
    Huditz, Regina
    Schlegel, Philipp
    Weber, Christophe
    Stangassinger, Manfred
    Haberkorn, Uwe
    Katus, Hugo A.
    Most, Patrick
    Pleger, Sven T.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (09): : 1691 - 1699
  • [36] A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats
    Qualcomm, San Diego, CA 92121, United States
    不详
    不详
    不详
    Physiol. Meas., 6 (701-715):
  • [37] Muscle Contraction and Pressure-Volume Loops in the Left-Heart
    Colorado-Cervantes, J. I.
    Varano, Valerio
    Teresi, Luciano
    Sansalone, Vittorio
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 : 43 - 44
  • [38] INVIVO ESTIMATION OF THE LEFT-VENTRICULAR PRESSURE-VOLUME LOOPS
    KIM, KH
    RITMAN, EL
    CLINICAL RESEARCH, 1985, 33 (04): : A867 - A867
  • [39] A NEW METHOD FOR DETERMINING PRESSURE-VOLUME LOOPS IN THE CLINICAL SETTING
    PURUT, CM
    SELL, TL
    JONES, RH
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 992 - 992