Comparison of admittance and cardiac magnetic resonance generated pressure-volume loops in a porcine model

被引:0
|
作者
Andersen, Stine [1 ,2 ]
Laursen, Pernille Holmberg [1 ,2 ]
Wood, Gregory John [1 ,2 ]
Lyhne, Mads Dam [2 ,4 ]
Madsen, Tobias Lynge [1 ,3 ]
Hansen, Esben Sovso Szocska [3 ]
Johansen, Peter [5 ]
Kim, Won Yong [1 ,2 ]
Andersen, Mads Jonsson [1 ,2 ]
机构
[1] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark
[2] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[3] Aarhus Univ, MR Res Ctr, Dept Clin Med, Aarhus, Denmark
[4] Aarhus Univ Hosp, Dept Anesthesiol & Intens Care, Aarhus, Denmark
[5] Aarhus Univ, Dept Elect & Comp Engn, Aarhus, Denmark
关键词
pressure-volume loops; cardiac magnetic resonance imaging; admittance; cardiac function; end-systolic elastance; RIGHT-VENTRICULAR DYSFUNCTION; SINGLE-BEAT ESTIMATION; IMAGING ANALYSIS; VALIDATION;
D O I
10.1088/1361-6579/ad4a03
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. Pressure-volume loop analysis, traditionally performed by invasive pressure and volume measurements, is the optimal method for assessing ventricular function, while cardiac magnetic resonance (CMR) imaging is the gold standard for ventricular volume estimation. The aim of this study was to investigate the agreement between the assessment of end-systolic elastance (Ees) assessed with combined CMR and simultaneous pressure catheter measurements compared with admittance catheters in a porcine model. Approach. Seven healthy pigs underwent admittance-based pressure-volume loop evaluation followed by a second assessment with CMR during simultaneous pressure measurements. Main results. Admittance overestimated end-diastolic volume for both the left ventricle (LV) and the right ventricle (RV) compared with CMR. Further, there was an underestimation of RV end-systolic volume with admittance. For the RV, however, Ees was systematically higher when assessed with CMR plus simultaneous pressure measurements compared with admittance whereas there was no systematic difference in Ees but large differences between admittance and CMR-based methods for the LV. Significance. LV and RV Ees can be obtained from both admittance and CMR based techniques. There were discrepancies in volume estimates between admittance and CMR based methods, especially for the RV. RV Ees was higher when estimated by CMR with simultaneous pressure measurements compared with admittance.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Admittance-based pressure-volume loops versus gold standard cardiac magnetic resonance imaging in a porcine model of myocardial infarction
    van Hout, Gerardus P. J.
    Jansen, Sanne J.
    Gho, Johannes M. I. H.
    Doevendans, Pieter A.
    van Solinge, Wouter W.
    Pasterkamp, Gerard
    Chamuleau, Steven A. J.
    Hoefer, Imo E.
    PHYSIOLOGICAL REPORTS, 2014, 2 (04):
  • [2] From pressure-volume loops and magnetic resonance imaging to mathematical models for cardiac surgery simulation
    Ripoli, A
    Glauber, M
    Positano, V
    Berti, S
    Lombardi, M
    Bevilacqua, S
    Solinas, M
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1163 - 1163
  • [3] Noninvasive Quantification of Pressure-Volume Loops From Brachial Pressure and Cardiovascular Magnetic Resonance
    Seemann, Felicia
    Arvidsson, Per
    Nordlund, David
    Kopic, Sascha
    Carlsson, Marcus
    Arheden, Hakan
    Heiberg, Einar
    CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (01) : e008493
  • [4] Closed Chest Biventricular Pressure-Volume Loop Recordings with Admittance Catheters in a Porcine Model
    Lyhne, Mads Dam
    Schultz, Jacob Gammelgaard
    Dragsbaek, Simone Juel
    Hansen, Jacob Valentin
    Mortensen, Christian Schmidt
    Kramer, Anders
    Nielsen-Kudsk, Jens Erik
    Andersen, Asger
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (171):
  • [5] Admittance-based pressure-volume loop measurements in a porcine model of chronic myocardial infarction
    van Hout, G. P. J.
    de Jong, R.
    Vrijenhoek, J. E. P.
    Timmers, L.
    Duckers, H. J.
    Hoefer, I. E.
    EXPERIMENTAL PHYSIOLOGY, 2013, 98 (11) : 1565 - 1575
  • [6] Cardiovascular pressure-volume loops
    Motshabi, P.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2023, 29 (05) : S1 - S5
  • [7] Real time pressure-volume loops in mice using complex admittance: measurement and implications
    Kottam, Anil T. G.
    Porterfield, John
    Raghavan, Karthik
    Fernandez, Daniel
    Feldman, Marc D.
    Valvano, Jonathan W.
    Pearce, John A.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 1942 - +
  • [8] INTRAOPERATIVE ASSESSMENT OF CARDIAC-FUNCTION UTILIZING PRESSURE-VOLUME LOOPS
    SELL, TL
    PURUT, CM
    SILVA, R
    JONES, RH
    CIRCULATION, 1986, 74 (04) : 4 - 4
  • [9] Real-Time Magnetic Resonance Imaging Technique for Determining Left Ventricle Pressure-Volume Loops
    Witschey, Walter R. T.
    Contijoch, Francisco
    McGarvey, Jeremy R.
    Ferrari, Victor A.
    Hansen, Michael S.
    Lee, Madonna E.
    Takebayashi, Satoshi
    Aoki, Chikashi
    Chirinos, Julio A.
    Yushkevich, Paul A.
    Gorman, Joseph H., III
    Pilla, James J.
    Gorman, Robert C.
    ANNALS OF THORACIC SURGERY, 2014, 97 (05): : 1597 - 1603
  • [10] Multiple pressure-volume loops recorded with sinusoidal low flow in a porcine acute respiratory distress syndrome model
    Bitzén, U
    Enoksson, J
    Uttman, L
    Niklason, L
    Johansson, L
    Jonson, B
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2006, 26 (02) : 113 - 119