EFFECT OF PRIME MOVER REGENERATOR RADIUS ON THE PERFORMANCE AND CHARACTERISTIC OF ACOUSTIC FIELD OF THERMOACOUSTIC REFRIGERATOR DRIVEN BY PRIME MOVER

被引:0
|
作者
Farikhah, Irna [1 ]
Isnandi, Rifqi Nurfadhilah [1 ]
Setiawan, Ikhsan [2 ]
Hermana, Rifki [1 ]
Rokhmawati, Endang Dian [3 ]
Nuroso, Harto [4 ]
Novita, Mega [5 ]
Margono, Margono [6 ]
机构
[1] Univ PGRI, Dept Mech Engn, Semarang, Indonesia
[2] Univ Gadjah Mada, Dept Phys, Yogyakarta, Indonesia
[3] Univ Negeri, Dept Phys Educ, Semarang, Indonesia
[4] Univ PGRI, Dept Phys Educ, Semarang, Indonesia
[5] Univ PGRI, Grad Sch Nat Sci Educ, Semarang, Indonesia
[6] Univ PGRI, Dept Elect Engn, Semarang, Indonesia
来源
THERMAL SCIENCE | 2024年 / 28卷 / 2C期
关键词
prime mover; refrigerator; thermoacoustic; acoustic field; ENGINE;
D O I
10.2298/TSCI230423225F
中图分类号
O414.1 [热力学];
学科分类号
摘要
Refrigerated truck is indispensable transportation for food and medicine. However, the truck has been using the harmful substance such as CFC or HCFC. Therefore, an alternative cooler is essential such as thermoacoustic refrigerator. The refrigerator is driven by the thermoacoustic heat engine (prime mover), so the prime mover can convert the thermal or waste heat into the acoustic energy for driving the refrigerator. There are some parameters that can improve the efficiency of the refrigerator system. The aim is to investigate the impact of prime mover regenerator radius on the efficiency and characteristic of acoustic field. It was found that the best performance of the whole refrigeration system was achieved when the radius is 0.68. The engine and cooler efficiency are 84% and 38%, respectively. In addition, the acoustic field characteristic was also analyzed to elucidate the mechanism in the refrigerator system.
引用
收藏
页码:1837 / 1848
页数:12
相关论文
共 50 条
  • [1] Frequency characteristic of thermoacoustic prime mover
    Tang, K
    Chen, GB
    Huang, YH
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 140 - 143
  • [2] Experimental research of a thermoacoustic prime mover and a refrigerator
    DONG Kaijun
    Chinese Journal of Acoustics, 2001, (04) : 371 - 377
  • [3] Experimental investigation of a pulse tube refrigerator driven by a thermoacoustic prime mover
    Qiu, LM
    Chen, GB
    Jiang, N
    Jiang, YL
    Yu, JP
    CRYOCOOLERS 11, 2001, : 301 - 307
  • [4] Experimental investigation of a thermoacoustic refrigerator driven by a standing wave twin thermoacoustic prime mover
    Hariharan, N. M.
    Sivashanmugam, P.
    Kasthurirengan, S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08): : 2420 - 2425
  • [5] STUDIES ON PERFORMANCE OF THERMOACOUSTIC PRIME MOVER
    Hariharan, N. M.
    Sivashanmugam, P.
    Kasthurirengan, S.
    EXPERIMENTAL HEAT TRANSFER, 2015, 28 (03) : 267 - 281
  • [6] Acoustic work flux measurement of a thermoacoustic prime mover
    Millet, C
    Deng, XH
    Francois, MX
    Guo, FZ
    Jebali, F
    Vidal, F
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 518 - 521
  • [7] Thermoacoustic prime mover sizing software
    Konaina, Tareq
    Alkhwildy, Ekhlas
    Yassen, Nasser
    Morad, Issa
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 : 1017 - 1026
  • [8] STABILITY CURVES FOR A THERMOACOUSTIC PRIME MOVER
    ATCHLEY, AA
    KUO, FM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (03): : 1401 - 1404
  • [9] Experimental study on a thermoacoustic prime mover
    Bai, X
    Jin, T
    Chen, GB
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 522 - 525
  • [10] Experimental research of thermoacoustic prime mover
    Zhou, SL
    Matsubara, Y
    CRYOGENICS, 1998, 38 (08) : 813 - 822