STUDIES ON PERFORMANCE OF THERMOACOUSTIC PRIME MOVER

被引:11
|
作者
Hariharan, N. M. [1 ]
Sivashanmugam, P. [2 ,3 ]
Kasthurirengan, S. [3 ]
机构
[1] Natl Inst Technol, Dept Chem Engn, Tiruchirappalli 620015, Tamil Nadu, India
[2] Natl Inst Technol, Dept Chem Engn, Heat Transfer Res Lab, Tiruchirappalli 620015, Tamil Nadu, India
[3] Indian Inst Sci, Ctr Cryogen Technol, Bangalore 560012, Karnataka, India
关键词
thermoacoustic prime mover; resonator length; stack length; plate thickness; Design Environment for Low Amplitude Thermoacoustic Energy Conversion software; DESIGN; TUBE; OPTIMIZATION; LENGTH; ENGINE; ONSET;
D O I
10.1080/08916152.2013.871605
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermoacoustic engines are the devices that convert thermal energy into acoustic energy without moving parts. The main objective of this study is to analyze the performance of a thermoacoustic prime mover measured in terms of onset temperature difference, frequency, and pressure amplitude by varying resonator, stack length, and plate thickness. From the experiments, it is observed that onset temperature difference and pressure amplitude increases with increase in resonator and stack length with minimum plate thickness, whereas the frequency increases with decrease in resonator and stack length with higher plate thickness. The experimental results are compared with simulated results via Design Environment for Low Amplitude Thermoacoustic Energy Conversion software (Los Alamos National Laboratory, Los Alamos, New Mexico, USA).
引用
收藏
页码:267 / 281
页数:15
相关论文
共 50 条
  • [1] Experimental Studies of the Influence of Prandtl Number on the Performance of a Thermoacoustic Prime Mover
    Kamble, B. V.
    Kuzhiveli, B. T.
    Jain, Rishabh
    Prasad, S.
    Kasthurirengan, S.
    Behera, U.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 768 - 775
  • [2] Influence of operational parameters on performance of twin thermoacoustic prime mover CFD studies
    Jabbar, P.
    Hariharan, N. M.
    Sivashanmugam, P.
    Kasthurirengan, S.
    [J]. ENGINEERING COMPUTATIONS, 2016, 33 (03) : 759 - 766
  • [3] Studies of Performance Characteristics of Twin Thermoacoustic Prime Mover with Gas Mixtures as Working Fluids
    Behera, U.
    Kasthurirengan, S.
    Kamble, B.
    Kuzhiveli, B.
    Krishnamoorthy, V.
    [J]. 12TH CRYOGENICS 2012 IIR INTERNATIONAL CONFERENCE, 2012, : 372 - 377
  • [4] Thermoacoustic prime mover sizing software
    Konaina, Tareq
    Alkhwildy, Ekhlas
    Yassen, Nasser
    Morad, Issa
    [J]. TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 : 1017 - 1026
  • [5] Frequency characteristic of thermoacoustic prime mover
    Tang, K
    Chen, GB
    Huang, YH
    [J]. CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 140 - 143
  • [6] STABILITY CURVES FOR A THERMOACOUSTIC PRIME MOVER
    ATCHLEY, AA
    KUO, FM
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (03): : 1401 - 1404
  • [7] Experimental research of thermoacoustic prime mover
    Zhou, SL
    Matsubara, Y
    [J]. CRYOGENICS, 1998, 38 (08) : 813 - 822
  • [8] Experimental study on a thermoacoustic prime mover
    Bai, X
    Jin, T
    Chen, GB
    [J]. CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 522 - 525
  • [9] Numerical analysis on thermoacoustic prime mover
    Zhang, Dongwei
    Jiang, Erhui
    Shen, Chao
    Zhou, Junjie
    Yang, Weiwei
    He, Yaling
    [J]. JOURNAL OF SOUND AND VIBRATION, 2019, 463
  • [10] EFFECT OF PRIME MOVER REGENERATOR RADIUS ON THE PERFORMANCE AND CHARACTERISTIC OF ACOUSTIC FIELD OF THERMOACOUSTIC REFRIGERATOR DRIVEN BY PRIME MOVER
    Farikhah, Irna
    Isnandi, Rifqi Nurfadhilah
    Setiawan, Ikhsan
    Hermana, Rifki
    Rokhmawati, Endang Dian
    Nuroso, Harto
    Novita, Mega
    Margono, Margono
    [J]. THERMAL SCIENCE, 2024, 28 (2C): : 1837 - 1848