Motion artifacts in capacitive ECG monitoring systems: a review of existing models and reduction techniques

被引:0
|
作者
Khalili, Matin [1 ,2 ]
GholamHosseini, Hamid [1 ,2 ]
Lowe, Andrew [1 ]
Kuo, Matthew M. Y. [3 ]
机构
[1] Auckland Univ Technol, Inst Biomed Technol, 6 St Paul St, Auckland 1010, New Zealand
[2] Auckland Univ Technol, Dept Elect & Elect Engn, 6 St Paul St, Auckland 1010, New Zealand
[3] AUT, Dept Comp Sci & Software Engn, 6 St Paul St, Auckland 1010, New Zealand
关键词
Adaptive filtering; Digital signal processing; ECG capacitive electrodes; Electrode-tissue impedance; Motion artifact; ELECTRODE; REMOVAL; NOISE; QUALITY; SURFACE; POWER; BODY;
D O I
10.1007/s11517-024-03165-1
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Current research focuses on improving electrocardiogram (ECG) monitoring systems to enable real-time and long-term usage, with a specific focus on facilitating remote monitoring of ECG data. This advancement is crucial for improving cardiovascular health by facilitating early detection and management of cardiovascular disease (CVD). To efficiently meet these demands, user-friendly and comfortable ECG sensors that surpass wet electrodes are essential. This has led to increased interest in ECG capacitive electrodes, which facilitate signal detection without requiring gel preparation or direct conductive contact with the body. This feature makes them suitable for wearables or integrated measurement devices. However, ongoing research is essential as the signals they measure often lack sufficient clinical accuracy due to susceptibility to interferences, particularly Motion Artifacts (MAs). While our primary focus is on studying MAs, we also address other limitations crucial for designing a high Signal-to-Noise Ratio (SNR) circuit and effectively mitigating MAs. The literature on the origins and models of MAs in capacitive electrodes is insufficient, which we aim to address alongside discussing mitigation methods. We bring attention to digital signal processing approaches, especially those using reference signals like Electrode-Tissue Impedance (ETI), as highly promising. Finally, we discuss its challenges, proposed solutions, and offer insights into future research directions.
引用
收藏
页码:3599 / 3622
页数:24
相关论文
共 50 条
  • [21] Sensitivity analysis of Heuer's method for motion-artifacts reduction in capacitive biopotential measurements
    Yang, K. T.
    Serteyn, A.
    Vullings, R.
    Bergmans, J. W. M.
    2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 192 - 195
  • [22] Motion Artifacts in Capacitive ECG Measurements: Reducing the Combined Effect of DC Voltages and Capacitance Changes Using an Injection Signal
    Serteyn, A.
    Vullings, R.
    Meftah, M.
    Bergmans, J. W. M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (01) : 264 - 273
  • [23] Cancellation of motion artifacts in ambulatory ECG signals using TD-LMS adaptive filtering techniques
    Xiong, Fan
    Chen, Dongyi
    Chen, Zhenghao
    Dai, Shumei
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2019, 58 : 606 - 618
  • [24] Reliable Motion Artifact Detection for ECG Monitoring Systems with Dry Electrodes
    Ottenbacher, Joerg
    Kirst, Malte
    Jatoba, Luciana
    Huflejt, Michal
    Grossmann, Ulrich
    Stork, Wilhelm
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1695 - +
  • [25] Adaptive motion-artifact reduction in capacitive ECG measurements by using the power-line interference
    Xu, Lin
    Rabotti, Chiara
    Zhang, Yijing
    Harpe, Pieter J. A.
    Mischi, Massimo
    Meftah, Mohammed
    Ouzounov, Sotir
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 195 - 199
  • [26] Reduction of skin stretch induced motion artifacts in electrocardiogram monitoring using adaptive filtering
    Liu, Yan
    Pecht, Michael G.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 153 - 156
  • [27] LOCALIZING OPERATORS IN THE SMART FACTORY: A REVIEW OF EXISTING TECHNIQUES AND SYSTEMS
    Syberfeldt, Anna
    Ayani, Mikael
    Holm, Magnus
    Wang, Lihui
    Lindgren-Brewster, Rodney
    2016 INTERNATIONAL SYMPOSIUM ON FLEXIBLE AUTOMATION (ISFA), 2016, : 179 - 185
  • [28] SIGNAL QUALITY ASSESSMENT FOR CAPACITIVE ECG MONITORING SYSTEMS USING BODY-SENSOR-IMPEDANCE
    Heuer, Stephan
    Chiriac, Sebastian
    Kirst, Malte
    Gharbi, Adnene
    Stork, Wilhelm
    BIOSIGNALS 2011, 2011, : 454 - 458
  • [29] Retrospective ECG gating technique for reduction of cardiac motion artifacts in multi-slice CT coronary angiography
    Hong, C
    Becker, CR
    Bruening, RD
    Schoepf, UO
    Knez, A
    Reiser, MF
    RADIOLOGY, 2000, 217 : 374 - 374
  • [30] ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges
    Serhani, Mohamed Adel
    El Kassabi, Hadeel T.
    Ismail, Heba
    Navaz, Alramzana Nujum