Comparison of intraocular pressure and anterior segment parameters in subjects with asymmetrical primary angle closure disease

被引:2
|
作者
Tan, Shayne S. [1 ]
Tun, Tin A. [1 ,2 ]
Aung, Tin [1 ,2 ]
Nongpiur, Monisha E. [1 ,2 ,3 ]
机构
[1] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[2] Duke NUS Med Sch, Singapore, Singapore
[3] Singapore Natl Eye Ctr, 11 Third Hosp Ave, Singapore 168751, Singapore
基金
英国医学研究理事会;
关键词
anterior segment; anterior segment imaging; asymmetrical primary angle closure; biometric; intraocular pressure; LASER PERIPHERAL IRIDOTOMY; VISUAL-FIELD DEFECTS; INTEROCULAR ASYMMETRY; IRIS THICKNESS; GLAUCOMA; ASSOCIATION; POPULATION; SUBTYPES; PEOPLE; NUMBER;
D O I
10.1111/ceo.14402
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To compare intraocular pressure (IOP) and anterior segment parameters between eyes with unilateral primary angle closure glaucoma (PACG) and their fellow eyes with primary angle closure (PAC) or primary angle closure suspect (PACS). Methods: Subjects underwent anterior segment imaging using 360-degree swept-source optical coherence tomography (SS-OCT, CASIA Tomey, Nagoya, Japan) and ocular investigations including gonioscopy and IOP measurement. Each SS-OCT scan (divided into 8 frames, 22.5 degrees apart) was analysed and an average was obtained for the following anterior segment parameters: iridotrabecular contact (ITC), angle opening distance (AOD750), iris thickness and curvature, anterior chamber width, depth and area (ACW, ACD and ACA) and lens vault (LV). Results: Among 132 unilateral PACG subjects (mean age: 62.91 +/- 7.2 years; 59.1% male), eyes with PACG had significantly higher presenting IOP (24.81 +/- 0.94 vs. 18.43 +/- 0.57 mmHg, p < 0.001), smaller gonioscopic Shaffer grade (2.07 +/- 0.07 vs. 2.31 +/- 0.07, p < 0.001) and a greater extent of peripheral anterior synechiae (PAS, 1.21 +/- 0.21 vs. 0.54 +/- 0.16 clock hours, p = 0.001). PACG eyes also exhibited increased ITC, ITC area, greater LV and smaller AOD750, ACD and ACA (all p < 0.05). Using the forward stepwise regression model, an increase in 1 mmHg in presenting IOP before laser peripheral iridotomy (LPI) increases the odds of having PACG by 9% (95% confidence interval 5%-14%). Conclusions: PACG eyes have higher presenting IOP, smaller anterior segment parameters, greater extent of PAS, and larger LV compared to their fellow eyes with angle closure. Narrower anterior chamber dimensions and higher presenting IOP before LPI may increase risk of chronic elevated IOP and glaucomatous optic neuropathy after LPI.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Quantitative evaluation of anterior chamber parameters using anterior segment optical coherence tomography in primary angle closure mechanisms
    Shabana, Noor
    Aquino, Maria C. D.
    See, Jovina
    Ce, Zheng
    Tan, Anna M.
    Nolan, Winifred P.
    Hitchings, Roger
    Young, Stephanie M.
    Loon, Seng Chee
    Sng, Chelvin C.
    Wong, Wanling
    Chew, Paul T. K.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (08): : 792 - 801
  • [42] Anterior Segment Optical Coherence Tomography: Is There a Clinical Role in the Management of Primary Angle Closure Disease?
    Nongpiur, Monisha E.
    Tun, Tin A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2020, 29 (01) : 60 - 66
  • [43] Evaluation of Anterior Segment Parameters in Pseudoexfoliative Glaucoma, Primary Angle-Closure Glaucoma, and Healthy Eyes
    Aksoy, Nilgun Ozkan
    Cakir, Burcin
    Dogan, Emine
    Alagoz, Gursoy
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (05): : 227 - 231
  • [44] Subgrouping of Primary Angle-Closure Suspects Based on Anterior Segment Optical Coherence Tomography Parameters
    Nongpiur, Monisha E.
    Gong, Tianxia
    Lee, Hwee Kuan
    Perera, Shamira A.
    Cheng, Li
    Foo, Li-Lian
    He, Mingguang
    Friedman, David S.
    Aung, Tin
    OPHTHALMOLOGY, 2013, 120 (12) : 2525 - 2531
  • [45] Corneal hysteresis and anterior segment optical coherence tomography anatomical parameters in primary angle closure suspects
    Hussnain, Syed Amal
    Kovacs, Kyle D.
    Warren, Joshua L.
    Teng, Christopher C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (05): : 468 - 472
  • [46] Subclassification of Primary Angle Closure Using Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopic Parameters
    Kwon, Junki
    Sung, Kyung Rim
    Han, Seungbong
    Moon, Ye Ji
    Shin, Joong Won
    OPHTHALMOLOGY, 2017, 124 (07) : 1039 - 1047
  • [47] Anterior Segment Imaging for Angle Closure
    Chansangpetch, Sunee
    Rojanapongpun, Prin
    Lin, Shan C.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 188 : XVI - XXIX
  • [48] Anterior segment optical coherence tomography of acute primary angle closure
    Zhang, Hai Tao
    Xu, Liang
    Cao, Wei Fang
    Wang, Ya Xing
    Jonas, Jost B.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (06) : 825 - 831
  • [49] Anterior segment optical coherence tomography of acute primary angle closure
    Hai Tao Zhang
    Liang Xu
    Wei Fang Cao
    Ya Xing Wang
    Jost B. Jonas
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 825 - 831
  • [50] Intraocular pressure and visual field loss in primary angle closure and primary open angle glaucomas
    Gazzard, G
    Foster, PJ
    Devereux, JG
    Oen, F
    Chew, P
    Khaw, PT
    Seah, S
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (06) : 720 - 725