Comparison of intraocular pressure and anterior segment parameters in subjects with asymmetrical primary angle closure disease

被引:2
|
作者
Tan, Shayne S. [1 ]
Tun, Tin A. [1 ,2 ]
Aung, Tin [1 ,2 ]
Nongpiur, Monisha E. [1 ,2 ,3 ]
机构
[1] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[2] Duke NUS Med Sch, Singapore, Singapore
[3] Singapore Natl Eye Ctr, 11 Third Hosp Ave, Singapore 168751, Singapore
基金
英国医学研究理事会;
关键词
anterior segment; anterior segment imaging; asymmetrical primary angle closure; biometric; intraocular pressure; LASER PERIPHERAL IRIDOTOMY; VISUAL-FIELD DEFECTS; INTEROCULAR ASYMMETRY; IRIS THICKNESS; GLAUCOMA; ASSOCIATION; POPULATION; SUBTYPES; PEOPLE; NUMBER;
D O I
10.1111/ceo.14402
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To compare intraocular pressure (IOP) and anterior segment parameters between eyes with unilateral primary angle closure glaucoma (PACG) and their fellow eyes with primary angle closure (PAC) or primary angle closure suspect (PACS). Methods: Subjects underwent anterior segment imaging using 360-degree swept-source optical coherence tomography (SS-OCT, CASIA Tomey, Nagoya, Japan) and ocular investigations including gonioscopy and IOP measurement. Each SS-OCT scan (divided into 8 frames, 22.5 degrees apart) was analysed and an average was obtained for the following anterior segment parameters: iridotrabecular contact (ITC), angle opening distance (AOD750), iris thickness and curvature, anterior chamber width, depth and area (ACW, ACD and ACA) and lens vault (LV). Results: Among 132 unilateral PACG subjects (mean age: 62.91 +/- 7.2 years; 59.1% male), eyes with PACG had significantly higher presenting IOP (24.81 +/- 0.94 vs. 18.43 +/- 0.57 mmHg, p < 0.001), smaller gonioscopic Shaffer grade (2.07 +/- 0.07 vs. 2.31 +/- 0.07, p < 0.001) and a greater extent of peripheral anterior synechiae (PAS, 1.21 +/- 0.21 vs. 0.54 +/- 0.16 clock hours, p = 0.001). PACG eyes also exhibited increased ITC, ITC area, greater LV and smaller AOD750, ACD and ACA (all p < 0.05). Using the forward stepwise regression model, an increase in 1 mmHg in presenting IOP before laser peripheral iridotomy (LPI) increases the odds of having PACG by 9% (95% confidence interval 5%-14%). Conclusions: PACG eyes have higher presenting IOP, smaller anterior segment parameters, greater extent of PAS, and larger LV compared to their fellow eyes with angle closure. Narrower anterior chamber dimensions and higher presenting IOP before LPI may increase risk of chronic elevated IOP and glaucomatous optic neuropathy after LPI.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Anterior segment imaging-based subdivision of subjects with primary angle-closure glaucoma
    M E Nongpiur
    E Atalay
    T Gong
    M Loh
    H K Lee
    M He
    S A Perera
    T Aung
    Eye, 2017, 31 (4) : 572 - 577
  • [32] Circadian Intraocular Pressure Fluctuation and Disease Progression in Primary Angle Closure Glaucoma
    Tan, Shaoying
    Yu, Marco
    Baig, Nafees
    Chan, Poemen Pui-man
    Tang, Fang Yao
    Tham, Clement C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (08) : 4994 - 5005
  • [33] Subtypes of primary angle closure disease based on age-independent anterior segment optical coherence tomography parameters
    Ruthra Umapathi
    Marco Yu
    Ching-Yu Cheng
    Raymond P. Najjar
    Rahat Husain
    Ching Lin Ho
    Tina T. Wong
    Pui Yi Boey
    Shamira Perera
    Eranga N. Vithana
    Tin Aung
    Monisha E. Nongpiur
    Eye, 2025, 39 (7) : 1384 - 1389
  • [34] Influence of Anterior Segment Biometric Parameters on the Anterior Chamber Angle Width in Eyes With Angle Closure
    Matsuki, Takaaki
    Hirose, Fumitaka
    Ito, Shin-ichiro
    Hata, Masayuki
    Hirami, Yasuhiko
    Kurimoto, Yasuo
    JOURNAL OF GLAUCOMA, 2015, 24 (02) : 144 - 148
  • [35] Effects of selective serotonin reuptake inhibitors on intraocular pressure and anterior segment parameters in open angle eyes
    Gunduz, Gamze Ucan
    Yener, Neslihan Parmak
    Kilincel, Oguzhan
    Gunduz, Cem
    CUTANEOUS AND OCULAR TOXICOLOGY, 2018, 37 (01) : 36 - 40
  • [36] Angle, anterior chamber parameters, and intraocular pressure changes after early phacoemulsification in acute angle-closure glaucoma
    Anbar, Mohamed A.
    Mahmoud, Hany A.
    Abdellah, Marwa M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (11): : 1147 - 1152
  • [37] Anterior Segment Parameters As Predictors of Intraocular Pressure Reduction After Phacoemulsification in Eyes with Open Angle Glaucoma
    Hsia, Yen C.
    Moghimi, Sasan
    Coh, Paul
    Chen, Rebecca I.
    Masis, Marisse
    Lin, Shan C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [38] Influence of Anterior Segment Biometric Parameters on the Anterior Chamber Angle Width in Eyes with Angle Closure and Open Angle
    Matsuki, Takaaki
    Hirose, Fumitaka
    Kameda, Takanori
    Hirami, Yasuhiko
    Kurimoto, Yasuo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [39] Comparison of anterior segment parameters in myopia with and without primary open-angle glaucoma
    Samuel Kyei
    Ebenezer Zaabaar
    Samuel Bert Boadi-Kusi
    John Baptist Vianney Abowine
    Maame Ama Amamoah Parkson Brew
    Frank Assiamah
    Kofi Asiedu
    International Ophthalmology, 2023, 43 : 2307 - 2313
  • [40] Comparison of anterior segment parameters in myopia with and without primary open-angle glaucoma
    Kyei, Samuel
    Zaabaar, Ebenezer
    Boadi-Kusi, Samuel Bert
    Abowine, John Baptist Vianney
    Brew, Maame Ama Amamoah Parkson
    Assiamah, Frank
    Asiedu, Kofi
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (07) : 2307 - 2313