Comparison of intraocular pressure and anterior segment parameters in subjects with asymmetrical primary angle closure disease

被引:2
|
作者
Tan, Shayne S. [1 ]
Tun, Tin A. [1 ,2 ]
Aung, Tin [1 ,2 ]
Nongpiur, Monisha E. [1 ,2 ,3 ]
机构
[1] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[2] Duke NUS Med Sch, Singapore, Singapore
[3] Singapore Natl Eye Ctr, 11 Third Hosp Ave, Singapore 168751, Singapore
基金
英国医学研究理事会;
关键词
anterior segment; anterior segment imaging; asymmetrical primary angle closure; biometric; intraocular pressure; LASER PERIPHERAL IRIDOTOMY; VISUAL-FIELD DEFECTS; INTEROCULAR ASYMMETRY; IRIS THICKNESS; GLAUCOMA; ASSOCIATION; POPULATION; SUBTYPES; PEOPLE; NUMBER;
D O I
10.1111/ceo.14402
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To compare intraocular pressure (IOP) and anterior segment parameters between eyes with unilateral primary angle closure glaucoma (PACG) and their fellow eyes with primary angle closure (PAC) or primary angle closure suspect (PACS). Methods: Subjects underwent anterior segment imaging using 360-degree swept-source optical coherence tomography (SS-OCT, CASIA Tomey, Nagoya, Japan) and ocular investigations including gonioscopy and IOP measurement. Each SS-OCT scan (divided into 8 frames, 22.5 degrees apart) was analysed and an average was obtained for the following anterior segment parameters: iridotrabecular contact (ITC), angle opening distance (AOD750), iris thickness and curvature, anterior chamber width, depth and area (ACW, ACD and ACA) and lens vault (LV). Results: Among 132 unilateral PACG subjects (mean age: 62.91 +/- 7.2 years; 59.1% male), eyes with PACG had significantly higher presenting IOP (24.81 +/- 0.94 vs. 18.43 +/- 0.57 mmHg, p < 0.001), smaller gonioscopic Shaffer grade (2.07 +/- 0.07 vs. 2.31 +/- 0.07, p < 0.001) and a greater extent of peripheral anterior synechiae (PAS, 1.21 +/- 0.21 vs. 0.54 +/- 0.16 clock hours, p = 0.001). PACG eyes also exhibited increased ITC, ITC area, greater LV and smaller AOD750, ACD and ACA (all p < 0.05). Using the forward stepwise regression model, an increase in 1 mmHg in presenting IOP before laser peripheral iridotomy (LPI) increases the odds of having PACG by 9% (95% confidence interval 5%-14%). Conclusions: PACG eyes have higher presenting IOP, smaller anterior segment parameters, greater extent of PAS, and larger LV compared to their fellow eyes with angle closure. Narrower anterior chamber dimensions and higher presenting IOP before LPI may increase risk of chronic elevated IOP and glaucomatous optic neuropathy after LPI.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of intraocular pressure and anterior segment parameters in subjects with asymmetrical primary angle closure disease: Comment
    Guo, Liang
    Wang, Na
    Yang, Lu
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 52 (09): : 1025 - 1026
  • [2] Comparison of intraocular pressure and anterior segment parameters in subjects with asymmetrical primary angle closure disease: Response
    Tan, Shayne S.
    Tun, Tin A.
    Nongpiur, Monisha E.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 52 (09): : 1026 - 1027
  • [3] Anterior Segment Parameters in Subjects with Asymmetric Primary Angle Closure Glaucoma
    Nongpiur, Monisha Esther
    Fan, Kenric R.
    Chiew, Jestin W.
    Cheong, Yap Sae
    Perera, Shamira
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [4] The Effects of Lens Extraction Surgery on Intraocular Pressure and Anterior Segment Parameters in Primary Angle-Closure Glaucoma
    Bayraktar, Serdar
    Erdal, Bura Dilara Yildirim
    Alta, Fatma Bura
    Turkay, Mine
    Sen, Emine
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2024, 54 (01): : 32 - 37
  • [5] Angle closure extent, anterior segment dimensions and intraocular pressure
    Porporato, Natalia
    Chong, Rachel
    Xu, Benjamin Y.
    Tun, Tin A.
    Quah, Joanne HuiMin
    Tan, Marcus
    Baskaran, Mani
    Cheng, Ching Yu
    Aung, Tin
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (07) : 927 - 934
  • [6] Anterior Segment OCT in Primary Angle Closure Disease Compared With Normal Subjects With Similar Shallow Anterior Chamber
    Xie, Qinghong
    Ma, Ping
    Patlidanon, Jutima
    Saifee, Murtaza
    Yonamine, Sean
    Yu, Yinxi
    Ying, Gui-Shuang
    Yang, Yangfan
    Li, Shuning
    Han, Ying
    JOURNAL OF GLAUCOMA, 2022, 31 (02) : 84 - 90
  • [7] Comparison of pretreatment measurements of anterior segment parameters in eyes with acute and chronic primary angle closure
    Satoru Yoshimizu
    Fumitaka Hirose
    Seiji Takagi
    Masashi Fujihara
    Yasuo Kurimoto
    Japanese Journal of Ophthalmology, 2019, 63 : 151 - 157
  • [8] Comparison of pretreatment measurements of anterior segment parameters in eyes with acute and chronic primary angle closure
    Yoshimizu, Satoru
    Hirose, Fumitaka
    Takagi, Seiji
    Fujihara, Masashi
    Kurimoto, Yasuo
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2019, 63 (02) : 151 - 157
  • [9] Comparison of Anterior Segment Parameters Between the Acute Primary Angle Closure Eye and the Fellow Eye
    Lee, Jong Rak
    Sung, Kyung Rim
    Han, Seungbong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) : 3646 - 3650
  • [10] Anterior Segment Parameters During Unilateral Acute Primary Angle Closure
    Wang, Wei
    Zhang, Xiulan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (08) : 5056 - 5056