A Comprehensive Evaluation of Tuned Vertical Isolation System for Seismic Risk Mitigation

被引:2
|
作者
Babaei, S. [1 ]
Jough, F. Karimi Ghaleh [1 ]
机构
[1] Final Int Univ, Fac Engn, Dept Civil Engn, Via Mersin 10,128, Kyrenia, Turkiye
关键词
vertical isolation; tuned mass damper; response spectrum analysis; time history analysis; structural control; DESIGN;
D O I
10.2478/jaes-2024-0004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Vertical isolation by dividing the building into two soft and stiff sub-systems benefits from the period shifts and the damping mechanism across the height. However, the displacement demand imposed on the soft sub-system is less applicable in congested urban areas. As a result, in this study, a hybrid system of vertical isolation system benefiting from a tuned soft subsystem divided into upper and lower portions is investigated. A parametric linear 3-Degree of Freedom (DoF) model of the system incorporating mass and frequency ratio of the sub-systems was introduced and analyzed by response spectrum in MATLAB. A closed-form solution for the system frequency and mode shapes was also established. Response spectrum analysis indicates increasing the Tuned Mass Damper (TMD)'s fundamental period to 2.5 times the soft sub-system's, reduces its displacement to more than 40 percent. The Multi Degree of Freedom (MDoF) model of the system is parametrically generated in MATLAB. Time history analysis of the building subjected to 40 records with 2 and 10 percent probabilities of exceedance in 50 years compared with conventional vertical isolation reveals the lower soft sub-system displacement can be reduced up to 45 percent by shifting drift to upper stories. The innovative tuned vertical isolation by demonstrating superior control performance as comprises lower floors' drift may be an applicable solution for adjacent high- and low-rise buildings.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [11] Seismic Control of Story Isolation System Using Tuned Mass Damper Inerter
    Liang, Qigang
    Wei, Jinyuan
    Li, Luyu
    JOURNAL OF ENGINEERING MECHANICS, 2023, 149 (03)
  • [12] Mitigation of the Seismic Impact on Storage Gas Tanks by Using Isolation System
    Henriques, Jose
    Morelli, Francesco
    Degee, Herve
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2022, 66 (03): : 752 - 760
  • [13] Performance evaluation of seismic foundation isolation system
    Kim, Jin Man
    Electronic Journal of Geotechnical Engineering, 2014, 19 (0E): : 1003 - 1011
  • [14] Performance evaluation of seismic foundation isolation system
    Kim, Jin Man
    Journal of Software Engineering, 2015, 9 (04): : 1003 - 1011
  • [15] Seismic mitigation of porcelain cylindrical electrical equipment using synergistic concept with base isolation and tuned mass damper
    Bai, Wen
    Zhu, Wang
    Moustafa, Mohamed A.
    Dai, Junwu
    EARTHQUAKE SPECTRA, 2025, 41 (01) : 654 - 681
  • [16] Geometrically nonlinearity analysis and performance evaluation of tuned inerter dampers for multidirectional seismic isolation
    Tai, Yu-ji
    Huang, Zhi-wen
    Chen, Chao
    Hua, Xu-gang
    Chen, Zheng-qing
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 168
  • [17] Seismic response mitigation of a wind turbine tower using a tuned parallel inerter mass system
    Zhang, Ruifu
    Zhao, Zhipeng
    Dai, Kaoshann
    ENGINEERING STRUCTURES, 2019, 180 : 29 - 39
  • [18] The Seismic Mitigation Design of Tuned Inerter Damper for Building Structure
    Liu L.
    Tan P.
    Yan W.
    Zhou F.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2018, 38 (04): : 751 - 757
  • [19] Mechanical performance of a vertical seismic isolation system employing a dish spring
    Zhang, Yu-Min
    Su, You-Po
    Su, Jing-Yu
    Chongqing Jianzhu Daxue Xuebao/Journal of Chongqing Jianzhu University, 2008, 30 (06): : 51 - 55
  • [20] Vertical seismic isolation system using v shaped link mechanism
    Wakabayashi, Nobuhiro
    Ohmata, Kenichiro
    Masuda, Takeshi
    Yokoo, Jyunichi
    Shimosaka, Haruo
    Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2009, 75 (749): : 26 - 32