A Comprehensive Evaluation of Tuned Vertical Isolation System for Seismic Risk Mitigation

被引:2
|
作者
Babaei, S. [1 ]
Jough, F. Karimi Ghaleh [1 ]
机构
[1] Final Int Univ, Fac Engn, Dept Civil Engn, Via Mersin 10,128, Kyrenia, Turkiye
关键词
vertical isolation; tuned mass damper; response spectrum analysis; time history analysis; structural control; DESIGN;
D O I
10.2478/jaes-2024-0004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Vertical isolation by dividing the building into two soft and stiff sub-systems benefits from the period shifts and the damping mechanism across the height. However, the displacement demand imposed on the soft sub-system is less applicable in congested urban areas. As a result, in this study, a hybrid system of vertical isolation system benefiting from a tuned soft subsystem divided into upper and lower portions is investigated. A parametric linear 3-Degree of Freedom (DoF) model of the system incorporating mass and frequency ratio of the sub-systems was introduced and analyzed by response spectrum in MATLAB. A closed-form solution for the system frequency and mode shapes was also established. Response spectrum analysis indicates increasing the Tuned Mass Damper (TMD)'s fundamental period to 2.5 times the soft sub-system's, reduces its displacement to more than 40 percent. The Multi Degree of Freedom (MDoF) model of the system is parametrically generated in MATLAB. Time history analysis of the building subjected to 40 records with 2 and 10 percent probabilities of exceedance in 50 years compared with conventional vertical isolation reveals the lower soft sub-system displacement can be reduced up to 45 percent by shifting drift to upper stories. The innovative tuned vertical isolation by demonstrating superior control performance as comprises lower floors' drift may be an applicable solution for adjacent high- and low-rise buildings.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [1] Efficiency of Risk Reduction by Installation of Seismic Isolation System for Vertical Furnace
    Komoda, Furnace-Kaori
    Yata, Masakazu
    Yamazaki, Yoshio
    Ueda, Toshihiko
    Aono, Sho
    Hibino, Hiroshi
    Nagashima, Ichiro
    Izumo, Yoji
    Kikuchi, Takumi
    2013 E-MANUFACTURING & DESIGN COLLABORATION SYMPOSIUM (EMDC), 2013,
  • [2] LOCAL SITE EFFECT EVALUATION IN SEISMIC RISK MITIGATION
    Gatmiri, Behrooz
    COUPLED SITE AND SOIL-STRUCTURE INTERACTION EFFECTS WITH APPLICATION TO SEISMIC RISK MITIGATION, 2009, : 89 - 99
  • [3] Seismic risk mitigation of cylindrical electrical equipment with a novel isolation device
    Cheng, Yongfeng
    Li, Sheng
    Lu, Zhicheng
    Liu, Zhenlin
    Zhu, Zhubing
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 111 : 41 - 52
  • [4] The Isolation Effect Analysis of Base and Story Isolation System in Vertical Seismic Action
    Duan, Shaowei
    Tao, Xiaowei
    Liu, Haikuan
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 3893 - +
  • [5] Intelligent seismic risk mitigation system on structure building
    Suryanita, R.
    Maizir, H.
    Yuniorto, E.
    Jingga, H.
    4TH INTERNATIONAL SEMINAR ON SUSTAINABLE URBAN DEVELOPMENT, 2018, 106
  • [6] Seismic risk mitigation
    Anagnostopoulos, SA
    EARTHQUAKE SCIENCE AND SEISMIC RISK REDUCTION, 2003, 32 : 250 - 283
  • [7] Shared Tuned Mass Dampers for Mitigation of Seismic Pounding
    Rupakhety, Rajesh
    Elias, Said
    Olafsson, Simon
    APPLIED SCIENCES-BASEL, 2020, 10 (06):
  • [8] Assessment of the Seismic Risk in the City of Yerevan and its Mitigation by Application of Innovative Seismic Isolation Technologies
    Melkumyan, Mikayel G.
    PURE AND APPLIED GEOPHYSICS, 2011, 168 (3-4) : 695 - 730
  • [9] Assessment of the Seismic Risk in the City of Yerevan and its Mitigation by Application of Innovative Seismic Isolation Technologies
    Mikayel G. Melkumyan
    Pure and Applied Geophysics, 2011, 168 : 695 - 730
  • [10] Design and study on vertical seismic isolation system by disk spring
    Zhang, Yumin
    Su, You-po
    2006 XI'AN INTERNATIONAL CONFERENCE OF ARCHITECTURE AND TECHNOLOGY, PROCEEDINGS: ARCHITECTURE IN HARMONY, 2006, : 417 - 420