A rare case of taper junction corrosion in semi-constrained total knee arthroplasty

被引:0
|
作者
Ekweariri, Nnadozie [1 ]
White, Ryan [1 ]
Brown, Nicholas [1 ]
Schmitt, Daniel [1 ]
机构
[1] Loyola Univ, Med Ctr, Dept Orthopaed Surg, 2160 South 1st Ave, Maywood, IL 60153 USA
来源
KNEE | 2024年 / 48卷
关键词
Total knee arthroplasty; Revision; Metallosis; Trunnionosis; IMPLANT; METALLOSIS; FAILURE; CREVICE; STEMS;
D O I
10.1016/j.knee.2024.02.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metallosis is a known yet rare late complication of unicompartmental and total knee arthroplasty (TKA), usually secondary to either metal -backed patellar component failure, mobile -bearing polyethylene dislocation, or catastrophic polyethylene failure and wear through. The majority of literature surrounding metallosis has been published in relation to total hip arthroplasty (THA) metal on metal bearing wear or mechanically assisted crevice corrosion. This case report describes the development of metallosis in a 77 -year -old male patient with advanced (Kellgren-Lawrence Grade 4) osteoarthritis with associated valgus deformity, who underwent index TKA with a semiconstrained revision knee system due to intraoperative medial collateral ligament laxity. The taper junction between the titanium alloy stem and cobalt chromium femoral component was the source of diffuse intra-articular metallosis. (c) 2024 Elsevier B.V. All rights reserved.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [31] Fracture at the stem–condylar junction of a modular femoral prosthesis in a varus–valgus constrained total knee arthroplasty
    D. D. Nikolopoulos
    I. G. Polyzois
    E. A. Magnissalis
    P. F. Bernard
    I. V. Michos
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 1071 - 1074
  • [32] Letter to the Editor: In Response to "Modular Taper Junction Corrosion and Failure: How to Approach a Recalled Total Hip Arthroplasty Implant"
    Davies, Joseph F.
    Leone, William A.
    Nessler, Joseph P.
    Perona, Paul G.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (02): : 449 - 450
  • [33] Revision Surgery for a Dislocated Constrained Total Knee Arthroplasty
    Hagedorn, Jonathan
    Levine, Brett R.
    ORTHOPEDICS, 2012, 35 (07) : E1099 - E1103
  • [34] EXCISION ARTHROPLASTY FOR INFECTED CONSTRAINED TOTAL KNEE REPLACEMENTS
    LETTIN, AWF
    NEIL, MJ
    CITRON, ND
    AUGUST, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02): : 220 - 224
  • [35] Revision Total Knee Arthroplasty with Use of a Constrained Condylar Knee Prosthesis
    Kim, Young-Hoo
    Kim, Jun-Shik
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06): : 1440 - 1447
  • [36] Rare cause of knee pain after total knee arthroplasty
    Ramsauer, T.
    Seitlinger, G.
    Niederseer, D.
    ORTHOPADE, 2013, 42 (11): : 969 - 970
  • [37] Rare Case of Traumatic Anterior Knee Dislocation of Total Knee Arthroplasty With a Serious Neurovascular Injury
    Novotny, Tomas
    Vanaskova, Eliska
    Soukup, Jan
    ARTHROPLASTY TODAY, 2021, 10 : 171 - 174
  • [38] The Case for Cementless Total Knee Arthroplasty
    Gold, Peter Aaron
    Garbarino, Luke
    Sodhi, Nipun
    Barrack, Robert
    Springer, Bryan D.
    Mont, Michael A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 36
  • [39] Early Outcomes of Revision Surgery for Taper Corrosion of Dual Taper Total Hip Arthroplasty in 187 Patients
    Dimitriou, Dimitris
    Liow, Ming Han Lincoln
    Tsai, Tsung-Yuan
    Leone, William A.
    Li, Guoan
    Kwon, Young-Min
    JOURNAL OF ARTHROPLASTY, 2016, 31 (07): : 1549 - 1554
  • [40] Late reconstruction of a traumatic trapeziometacarpal dislocation with a semi-constrained prosthesis: A case report
    Zollinger, Paul E.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2007, 33 (06) : 648 - 650