TOFHIR2: the readout ASIC of the CMS barrel MIP Timing Detector

被引:0
|
作者
Albuquerque, E. [5 ]
Araujo, M. [4 ]
Benaglia, A. [3 ]
Boletti, A. [4 ]
Bugalho, R. [5 ]
Coutinho, T. [5 ]
De Guio, F. [3 ,6 ]
Faccioli, P. [4 ]
Ferramacho, L. [5 ]
Firlej, M. [1 ]
Fiutowski, T. [1 ]
Francisco, R. [5 ]
Gallinaro, M. [4 ]
Ghezzi, A. [3 ,6 ]
Hollar, J.
Idzik, M. [1 ]
Legoinha, H. [4 ]
Leonardo, N. [4 ]
Leong, C. [5 ]
Lucchini, M. T. [3 ]
Malberti, M. [3 ]
Marozzo, G. [4 ]
Da Molin, G. [4 ]
Moron, J. [1 ]
Niknejad, T. [4 ,5 ]
Oliveira, L. [2 ]
Oliveira, N.
Palluotto, S. [3 ,6 ]
Pisano, M. [4 ]
Redaelli, N. [3 ]
Silva, C. [4 ]
Silva, J. C. [4 ,5 ]
Silva, R. [4 ,5 ]
Silveira, M. [5 ]
Swientek, K. [1 ,5 ]
de Fatis, T. Tabarelli [3 ,6 ]
Tavernier, S. [5 ]
Varela, J. [4 ,5 ]
Varela, V. [5 ]
White, S. [7 ]
Wulff, J. [4 ]
机构
[1] AGH Univ Krakow, Fac Phys & Appl Comp Sci, Krakow, Poland
[2] FCT UNL, CTS UNINOVA, DEE, Caparica, Portugal
[3] INFN, Sez Milano Bicocca, Milan, Italy
[4] LIP, Lisbon, Portugal
[5] PETsys Elect, Oeiras, Portugal
[6] Univ Milano Bicocca, Milan, Italy
[7] Univ Virginia, Charlottesville, VA USA
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 05期
基金
欧盟地平线“2020”;
关键词
Front-end electronics for detector readout; Radiation-hard electronics; Timing detectors; VLSI circuits; CMOS TECHNOLOGIES; PET;
D O I
10.1088/1748-0221/19/05/P05048
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.
引用
收藏
页数:34
相关论文
共 42 条
  • [31] On the Combination of a Dedicated HF Readout Circuit and the TOFPET2 ASIC to Push the Timing Performance of PET Systems
    Nadig, V.
    Gundacker, S.
    Radermacher, H.
    Schug, D.
    Weissler, B.
    Schulz, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S490 - S491
  • [32] H2GCROC: Design and performance of a dedicated very front-end ASIC for SiPM readout of the CMS High Granularity Calorimeter
    Gonzalez-Martinez, J. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1047
  • [33] Design and evaluation of EMPIX2, a 100 kfps, high dynamic range pixel detector readout ASIC for electron microscopy
    Wei, T.
    Yang, H.
    Deng, Z.
    Xue, T.
    Wang, X.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (12):
  • [34] Introducing Timepix2, a frame-based pixel detector readout ASIC measuring energy deposition and arrival time
    Wong, W. S.
    Alozy, J.
    Ballabriga, R.
    Campbell, M.
    Kremastiotis, I
    Llopart, X.
    Poikela, T.
    Sriskaran, V
    Tlustos, L.
    Turecek, D.
    RADIATION MEASUREMENTS, 2020, 131 (131)
  • [35] The APA Pixel Readout ASIC for an APD Based Fast 2D X-Ray Hybrid Pixel Detector
    Thil, Christophe
    Baron, Alfred Q. R.
    Dautet, Henri
    Davies, Murray
    Fajardo, Pablo
    Fischer, Peter
    Goettlicher, Peter
    Graafsma, Heinz
    Herve, Christian
    Rueffer, Rudolf
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 496 - 500
  • [36] VAS_UM/TAT4 ASIC readout systems for 3D CdZnTe/HgI2 detector arrays
    Zhang, Feng
    He, Zhong
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 950 - 954
  • [37] Pixel readout ASIC for an APD based 2D X-ray hybrid pixel detector with sub-nanosecond resolution
    Thil, Ch.
    Baron, A. Q. R.
    Fajardo, P.
    Fischer, P.
    Graafsma, H.
    Rueffer, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 461 - 464
  • [38] Fast Readout ASIC for Si-Strip Detector in the J-PARC Muon g-2/EDM Experiment and Other Related Applications
    Ueno, K.
    Ikeda, H.
    Ikeno, M.
    Kohriki, T.
    Mibe, T.
    Nishimura, S.
    Uchida, T.
    Sasaki, O.
    Saito, N.
    Tanaka, M.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [39] Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASIC
    Wang, Mingchen
    Wang, Yonggang
    Wang, Liwei
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2021, 5 (03) : 451 - 458
  • [40] Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASIC
    Mingchen Wang
    Yonggang Wang
    Liwei Wang
    Radiation Detection Technology and Methods, 2021, 5 : 451 - 458