Design and evaluation of EMPIX2, a 100 kfps, high dynamic range pixel detector readout ASIC for electron microscopy

被引:0
|
作者
Wei, T.
Yang, H.
Deng, Z. [1 ]
Xue, T.
Wang, X.
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2023年 / 18卷 / 12期
关键词
Front-end electronics for detector readout; Pixelated detectors and associated VLSI electronics; Solid state detectors;
D O I
10.1088/1748-0221/18/12/C12007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
EMPIX2 is a novel hybrid pixel detector readout ASIC for electron microscopy with a maximum frame rate of 100 kfps and a very large dynamic range (5 x 10(5):1). It features 128 x 128 square pixels at a pitch of 150 mu m. Adaptive gain switching and charge pump technology are applied to enhance the dynamic range. The pixels can operate in two modes: pulse mode and continuous mode. In pulse mode, ultra-fast gain switching enables a rapid response to pulsed electron sources, making it highly suitable for UEM applications. In continuous mode, the power consumption and dynamic range are optimized for STEM applications. The readout is frame-based, and digital image data is output by 64 pairs of LVDS drivers working in DDR mode at a clock frequency of 400 MHz. A dedicated data acquisition system was developed for the transmission and processing of the image data. Preliminary verification of the readout chip was performed using an on-chip calibration source.
引用
收藏
页数:11
相关论文
共 11 条
  • [1] High Dynamic Range Pixel Array Detector for Scanning Transmission Electron Microscopy
    Tate, Mark W.
    Purohit, Prafull
    Chamberlain, Darol
    Nguyen, Kayla X.
    Hovden, Robert
    Chang, Celesta S.
    Deb, Pratiti
    Turgut, Emrah
    Heron, John T.
    Schlom, Darrell G.
    Ralph, Daniel C.
    Fuchs, Gregory D.
    Shanks, Katherine S.
    Philipp, Hugh T.
    Muller, David A.
    Gruner, Sol M.
    MICROSCOPY AND MICROANALYSIS, 2016, 22 (01) : 237 - 249
  • [2] AGIPD 1.0: The High-Speed High Dynamic Range Readout ASIC for the Adaptive Gain Integrating Pixel Detector at the European XFEL
    Allahgholi, A.
    Becker, J.
    Bianco, L.
    Delfs, A.
    Goettlicher, P.
    Graafsma, H.
    Hirsemann, H.
    Jack, S.
    Klyuev, A.
    Lange, S.
    Marras, A.
    Sheviakov, I.
    Trunk, U.
    Xia, Q.
    Zhang, J.
    Zimmer, M.
    Dinapoli, R.
    Greiffenberg, D.
    Mezza, D.
    Mozzanica, A.
    Schmitt, B.
    Shi, X.
    Klanner, R.
    Schwandt, J.
    Gronewald, M.
    Krueger, H.
    Rah, S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [3] Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy
    Philipp, Hugh T.
    Tate, Mark W.
    Shanks, Katherine S.
    Mele, Luigi
    Peemen, Maurice
    Dona, Pleun
    Hartong, Reinout
    van Veen, Gerard
    Shao, Yu-Tsun
    Chen, Zhen
    Thom-Levy, Julia
    Muller, David A.
    Gruner, Sol M.
    MICROSCOPY AND MICROANALYSIS, 2022, 28 (02) : 425 - 440
  • [4] The High Dynamic Range Pixel Array Detector (HDR-PAD): Concept And Design
    Shanks, Katherine S.
    Philipp, Hugh T.
    Weiss, Joel T.
    Becker, Julian
    Tate, Mark W.
    Gruner, Sol M.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2015), 2016, 1741
  • [5] A Low-Noise High-Dynamic Range Charge Sensitive Amplifier for Gas Particle Detector Pixel Readout LSIs
    Li, Fei
    Miyahara, Masaya
    Matsuzawa, Akira
    IEICE TRANSACTIONS ON ELECTRONICS, 2013, E96C (06) : 903 - 911
  • [6] Design and Characterization of the ePix10k prototype: a High Dynamic Range integrating pixel ASIC for LCLS detectors.
    Caragiulo, P.
    Dragone, A.
    Markovic, B.
    Herbst, R.
    Nishimura, K.
    Reese, B.
    Herrmann, S.
    Hart, P.
    Blaj, G.
    Segal, J.
    Tomada, A.
    Hasi, J.
    Carini, G.
    Kenney, C.
    Haller, G.
    ADVANCES IN X-RAY FREE-ELECTRON LASERS INSTRUMENTATION III, 2015, 9512
  • [7] Design and Characterization of the ePix10k prototype: a High Dynamic Range integrating pixel ASIC for LCLS detectors.
    Caragiulo, P.
    Dragone, A.
    Markovic, B.
    Herbst, R.
    Nishimura, K.
    Reese, B.
    Herrmann, S.
    Hart, P.
    Blaj, G.
    Segal, J.
    Tomada, A.
    Hasi, J.
    Carini, G.
    Kenney, C.
    Haller, G.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [8] Characterisation of the high dynamic range Large Pixel Detector (LPD) and its use at X-ray free electron laser sources
    Veale, M. C.
    Adkin, P.
    Booker, P.
    Coughlan, J.
    French, M. J.
    Hart, M.
    Nicholls, T.
    Schneider, A.
    Seller, P.
    Pape, I.
    Sawhney, K.
    Carini, G. A.
    Hart, P. A.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [9] Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASIC
    Wang, Mingchen
    Wang, Yonggang
    Wang, Liwei
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2021, 5 (03) : 451 - 458
  • [10] Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASIC
    Mingchen Wang
    Yonggang Wang
    Liwei Wang
    Radiation Detection Technology and Methods, 2021, 5 : 451 - 458