Dynamic spectral extraction method with approximately the same optical path length of non-invasive quantitative analysis of human blood components

被引:0
|
作者
Wang, Kang [1 ,2 ]
Li, Gang [1 ]
Wang, Shuo [2 ]
Lin, Ling [2 ]
机构
[1] Tianjin Univ, Med Sch, Tianjin 300072, Peoples R China
[2] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrumen, Tianjin 300072, Peoples R China
关键词
Non-invasive quantitative analysis of human; blood components; Dynamic spectral extraction method with approximately the same optical path length; Nonlinear; Peak-to-peak value of PPG; Sample selection method;
D O I
10.1016/j.measurement.2024.115292
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The non-invasive quantitative analysis of blood components using spectroscopic methods based on Beer-Lambert law, and dynamic spectroscopic theory needs to meet the four applicable conditions of this law. However, in practical applications, due to the scattering characteristics of human tissue, it is difficult to meet the two conditions (parallel monochromatic light and non-scattering homogeneous system of absorbing substances), which will reduce the accuracy of quantitative analysis. To reduce the principle error caused by scattering, this paper proposes an extraction method for dynamic spectra with approximately the same optical path length. This method extracts approximately the same absorbance values from photoplethysmographic (PPG) spectral signals. A smaller absorbance value corresponds to a thinner blood layer, in which light can be approximated as parallel light, thus maximizing the satisfaction of the conditions of Beer-Lambert law. In the experimental, compared with the traditional single-edge extraction method, the proposed method has higher prediction accuracy. The correlation coefficients of the total cholesterol and triglycerides increased by 31.22% and 38.05%, and the root mean square errors decreased by 29.63% and 37.14%. The results show that the methods can significantly enhance the robustness of non-invasive quantitative analysis of blood components based on dynamic spectral theory.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Determination of New Non-Invasive Blood Glucose Detection Method Based on Spectral Decomposition
    Chen Jian-hong
    Lin Zhi-qiang
    Sun Chao-yue
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (08) : 2378 - 2383
  • [22] A novel non-invasive optical method for quantitative visualization of pH dynamics in the rhizosphere of plants
    Blossfeld, Stephan
    Gansert, Dirk
    PLANT CELL AND ENVIRONMENT, 2007, 30 (02): : 176 - 186
  • [23] QUANTITATIVE NON-INVASIVE METHOD OF MEASURING CEREBRAL BLOOD-FLOW (CBF) IN NEWBORN
    LEAHY, F
    SANKARAN, K
    CATES, D
    MACCALLUM, M
    RIGATTO, H
    PEDIATRIC RESEARCH, 1978, 12 (04) : 553 - 553
  • [24] QUANTITATIVE-DETERMINATION OF MUSCLE BLOOD-FLOW - A NEW NON-INVASIVE METHOD
    WEBER, F
    ANLAUF, M
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1988, 10 (04) : 726 - 726
  • [25] A non-invasive optical monitoring system for the multi-spectral determination of absorption changes in blood
    Kraitl, J
    Ewald, H
    OPTO-IRELAND 2005: OPTICAL SENSING AND SPECTROSCOPY, 2005, 5826 : 687 - 695
  • [26] A dynamic spectrum optimized single-trail extraction method for noninvasive analysis of human blood components
    Li, Gang
    Cheng, Leiyang
    Fan, Meiling
    Lin, Ling
    INFRARED PHYSICS & TECHNOLOGY, 2022, 126
  • [27] Dynamic optical breast imaging: a non-invasive, adjunctive method to detect breast cancer
    Gatzemeier, W
    Scelsi, A
    Galetti, K
    Villani, L
    Tinterri, C
    Secci, A
    BREAST CANCER RESEARCH AND TREATMENT, 2004, 88 : S223 - S223
  • [28] Dynamic spectrum: a brand-new non-invasive blood component measure method
    Li, Gang
    Wang, Yan
    Lin, Ling
    Liu, Yuliang
    Li, Xiaoxia
    Lu, Stephen C-Y.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1960 - 1963
  • [29] Preliminary research on feasibility of non-invasive sensing of blood multifunction using optical method
    Ma, YW
    Xu, KX
    Liu, Y
    APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 153 - 154
  • [30] Quantitative Measurement of Fe(II) in Human Blood with Spectral Analysis Method
    Xu Xiao-feng
    Zhao Fu-li
    Wang Shuang
    Ye Bao-hui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (12) : 2927 - 2930